Department Of Science And Technology - West Bengal
37563485 bids are invited for furnace tubular gradient tube furnace total quantity : 1...
37563485 bids are invited for furnace tubular gradient tube furnace total quantity : 1...
35353650 bids are invited for atmospheric controlled vertical tube furnace (q3) mse total quantity : 1...
35161765 tender for supply of tube furnace...
33446908 tender enquiry document for purchase of three zone split tube furnace for & on behalf of sric iit kharagpur...
33409062 supply of three zone split tube furnace , three zone split tube furnace , three zone split tube furnace...
32898234 bids are invited for 1361257818/catalyst tubes, furnace, l&t (q3) total quantity : 39...
32517711 annual rate contract for maintenance of boiler pressure parts of stage i and stage ii btps under 2 economiser tube jointtube od 51 mm, thickness 4.8 mm, material: sa 210 gr.c orequivalent 3 insert at furnace wall, goose necks pannel & roof tube ( 1 insert = 02 nos. joint ) tube od:63.5 mm to 69.9 mm, thickness from 5.1 to 6.3 mm, material:sa 210 gr. a or equivalent 4 joint at saturated screenroof & side wall, screen tube, primarysuperheater tube, secondary superheater tube. ( od: 63.5 mm, thickness: 5 mm upto 6.9 mm, material:sa213t11 or equivalnt ) 5 joint at reheater tube / insert at furnace wall, goose neck, s panel &roof tube. 6 second pass scaffolding 7 economiser coil liftingrepairing, fitting & jointing with proper alignment for unit 1 & 2 ( ifrequired for preventive checking beyond leakage area ) 8 primary & secondary superheater coilpulling, inspection and proper alignment of coil & panelwith clit and support welding of unit 1 & 2 ( if checkingrequired for preventive inspection ) 9 maintenance of boiler pressure part stage ii 10 lp water cleaningeconomizer zone, psh & prh 11 joint for lnsertion of water wall tube, cage rear wall below main cavity & baffle wall tube below maincavity, size: 63.5x5.4, mat: bs3059 / 45s2 or 5a210gr.c. 12 insertion joint for division wall tubesize: 82.5x7, mat: bs3059 / 45s2; or sa210gr.c 13 joint for lnsertion of furnace roof, cage rear wall & baffle wall tube above main cavity, size:63.5x4.8, mat: bs3059 / 620s2 or sa213t11 14 joint for insertion of economiser tubesize: 38.1x3.6, mat: bs3o59 / 45s2 or sa210gr.c 15 insertion joint of psh bottom & middlesize:57.1x6, mat: bs3059 / 620s2 or sa213t11 16 joint for insertion of psh top bank tubetube, size: 63.5x3.6, mat: bs3059 / 33s2 orsa210gr.c 17 insertion joint of prh bottom & middlesize: 57x3.2, mat: bs3059 / 620s2 or sa213t11 18 joint for lnsertion of prh top bank tubesize: 57x3.2, mat: bs3059 / 620s2 or sa213t11 19 joint for lnsertion of plsh and fshinlet tube, size: 44.5x7, mat: sa213t22 20 joint for lnsertion of fsh & frh tubesize: 50.8x3.6, mat: sa213t91 21 economiser / psh / prh coil lifting, inspection repairing and fitting with proper alignment ( if requiredfor preventive inspection beyond the leakage area ) 22 platen sh, fsh, frh coil pullinginspection and proper alignment of coil and panel with clit andsupport welding 23 second pass scaffolding per 6 meter 24 common work for stage i&ii 25 stress relieving 26 radiography 27 removal and refitting of refractory 28 replacement of high pressure valve size upto 2 29 replacement of high pressure line ( 1 / 2 to 4 ) ( unit of 01 number includes two joints ) 30 deinsulation & insulation with claddingof wall, casing and pipe and other area of boiler 31 hp valve welding from 50 nb upto 100 nbpipe 32 hp valve gland packing replacementupto 6 33 hp valve servicingincluding gland packing & bonnet seal replacement upto 4 34 d metering of boiler tubeat any area of boiler for thickness measurement ( minimum survey150 nos. / day ) 35 minimum mobilization chargeif total executed job value less than rs.15000.00 36 vertical scaffoldingfor approaching roof tube / reheater / secondary sh ( per 6 metervertical ) for stage i & for approaching furnace / roof tube / pendent reheater / platen / fsh & division wall ( per 6 metervertical ) for stage ii 37 horizontal scaffolding for approaching platen sh / scw / roof tubes / furnace ( per 6meter horizontal ) for stage i & for approaching rh / platen sh / final sh / divisional wall / scw / roof tubes / furnace ( per 6 meter horizontal ) for stage ii 38 guard tube and guard plateremoval, fabrication and fitting 39 build up in eroded tubesas per requirement 40 repairing of skin casing 41 fabrication of bends of any degree of any boiler tube 42 fitting and welding of tube attachment wherever require 43 membrane strip fitting & welding 44 fabrication and erection of steel itemsby ms plate / ms angle / ms channel / i beam etc. 45 boiler metal temp tc & mounting replace 46 thermowell replacement in hp line...
32498765 supply and installation of slow speed cutting machine and horizontal tube furnace under dst serb research project at department of metallurgical and material engineering pi dr amrita kundu jadavpur university main campus...
32036063 supply and installation of slow speed cutting machine and horizontal tube furnace under dst serb research project at department of metallurgical and material engineering pi dr amrita kundu jadavpur university main campus , equipments , slow speed cutting machine ( technical specifications details in nit document ) , horizontal tube furnace ( technical specifications details in nit document ) ...
31640141 bids are invited for high temperature furnace with gas (programmable dual zone / sliding tube furnace) facility (q3) total quantity : 1...
29910520 supply of supply, installation &supply, installation &,supply, installation & demonstration of tube furnace with digitalcontrol box for strohlein apparatus. along with all accessories as per annexure& calibration certificate from nabl accriditade lab. => limited...
29696594 bids are invited for two zone tube furnace two zone tube furnace total quantity : 1...
29201845 three zone split tube chemical vapor deposition furnace with a pair of rails to slide the tube furnace three zone split tube chemical vapor deposition furnace with a pair of rails to slide the tube furnace , three zone split tube chemical vapor deposition furnace with a pair of rails to slide the tube furnace , three zone split tube chemical vapor deposition furnace with a pair of rails to slide the tube furnace...
28732821 supply , installation, commissioning and training of split type tube furnace for the distillation of chalcogenide glass temperature supply , installation, commissioning and training of split type tube furnace for the distillation of chalcogenide glass temperature , split type tube furnace for the distillation of chalcogenide glass (specs as per tender document) , gst on item , packing & forwarding , gst on packing & forwarding , inland transportation, insurance & other charges , gst on inland transporation, insurance etc. , installation, commissioning and training charges , gst on installation, commissioning and training charges , any other charges , any other charges...
28611628 “supply, installation, commissioning and training of tube furnace”...
28588470 supply, installation, commissioning and training of tube furnace supply, installation, commissioning and training of tube furnace , tube furnace , installation, commissioning and training , packing and forwarding , transportation charges , insurance , other charges ( if any ) , gst on the item ( sl. no. 1 ) , gst on incidental services ( sl. no. 2 6 ) ...
27238307 supply of compact three zone gradient high temp. split tube furnace with 90 deg split option for horizontal mode using free radiating wire elements...
27212122 compact three zone gradient high temp . split tube furnace with 90 deg split option for horizontal mode using free radiating wire elements ( kanthal or better ) . ...
27064039 supply of single zone horizontal vacuum tube furnace with pump and all accessories...
26962067 purchase and installation of 1200 deg c tube furnace with independent controller...
26748959 tender for 1500 degree c general purpose tube furnace . ...
26619830 annual rate contract for maintenance of boiler pressure parts of stage i and stage ii , btps under banda dept . , btps , wbpdcl annual rate contract for maintenance of boiler pressure parts of stage i and stage ii , btps under b and a dept . , btps , wbpdcl , maintenence of boiler pr . parts stage iunit capacity 60mwx2 , economiser tube jointtube od 51 mm , thickness 4 . 8 mm , material: sa 210 gr . c or equivalent , insert at furnace wall , goose necks pannel & roof tube ( 1 insert = 02 nos . joint ) tube od:63 . 5 mm to 69 . 9 mm , thickness from 5 . 1 to 6 . 3 mm , material: sa 210 gr . a or equivalent , joint at saturated screenroof & side wall , screen tube , primary superheater tube , secondary superheater tube . ( od: 63 . 5 mm , thickness: 5 mm upto 6 . 9 mm , material: sa213t11 or equivalnt ) , insert at furnace wall , goose necks pannel & roof tube ( 1 insert = 02 nos . joint ) tube od:63 . 5 mm to 69 . 9 mm , thickness from 5 . 1 to 6 . 3 mm , material: sa 210 gr . a or equivalent , joint at saturated screenroof & side wall , screen tube , primary superheater tube , secondary superheater tube . ( od: 63 . 5 mm , thickness: 5 mm upto 6 . 9 mm , material: sa213t11 or equivalnt ) , insert at furnace wall , goose necks pannel & roof tube ( 1 insert = 02 nos . joint ) tube od:63 . 5 mm to 69 . 9 mm , thickness from 5 . 1 to 6 . 3 mm , material: sa 210 gr . a or equivalent , joint at saturated screenroof & side wall , screen tube , primary superheater tube , secondary superheater tube . ( od: 63 . 5 mm , thickness: 5 mm upto 6 . 9 mm , material: sa213t11 or equivalnt ) , maintenence of boiler pr . parts stage iiunit capacity 215 mwx1 , lp water cleaningeconomizer zone , psh & prh , joint for lnsertion of water wall tube , cage rear wall below main cavity & baffle wall tube below main cavity , size: 63 . 5x5 . 4 , mat: bs3059/45s2 or 5a210gr . c , insertion joint for division wall tubesize: 82 . 5x7 , mat: bs3059/45s2; or sa210gr . c , joint for lnsertion of furnace roof , cage rear wall & baffle wall tube above main cavity , size:63 . 5x4 . 8 , mat: bs3059/620s2 or sa213t11 , joint for insertion of economiser tubesize: 38 . 1x3 . 6 , mat: bs3o59/45s2 or sa210gr . c , insertion joint of psh bottom & middlesize:57 . 1x6 , mat: bs3059/620s2 or sa213t11 , joint for insertion of psh top bank tubetube , size: 63 . 5x3 . 6 , mat: bs3059/33s2 orsa210gr . c , insertion joint of prh bottom & middlesize: 57x3 . 2 , mat: bs3059/620s2 or sa213t11 , joint for lnsertion of prh top bank tubesize: 57x3 . 2 , mat: bs3059/620s2 or sa213t11 , joint for lnsertion of plsh and fsh inlet tube , size: 44 . 5x7 , mat: sa213t22 , joint for lnsertion of fsh & frh tubesize: 50 . 8x3 . 6 , mat: sa213t91 , economiser/psh/prh coil lifting , inspection repairing and fitting with proper alignment ( if required for preventive inspection beyond the leakage area ) , platen sh , fsh , frh coil pullinginspection and proper alignment of coil and panel with clit and support welding , second pass scaffolding per 6 meter , common work for stage i & ii , stress relieving , radiography , lremoval and refitting of refractory , replacement of high pressure valve size upto 2 , replacement of high pressure line ( 1/2 to 4 ) ( unit of 01 number includes two joints ) , deinsulation & insulation with claddingof wall , casing and pipe and other area of boiler , hp valve welding from 50 nb upto 100 nbpipe , hp valve gland packing replacementupto 6 , hp valve servicingincluding gland packing & bonnet seal replacement upto 4 , d metering of boiler tubeat any area of boiler for thickness measurement ( minimum survey 150 nos . /day ) , minimum mobilization chargeif total executed job value less than rs . 15000 . 00 , vertical scaffoldingfor approaching roof tube/ wall reheater/ mrh/ platen/ division panel ( per 6 meter vertical ) for stage i & for approaching furnace/ roof tube/ pendent reheater/ platen/fsh & division panel ( per 6 meter vertical ) for stage ii , horizontal scaffolding for approaching platen sh/ divisional wall/ scw/ roof tubes/furnace ( per 6 meter horizontal ) for stage i & for approaching rh/ platen sh / final sh / divisional panel/scw/ roof tubes/ furnace ( per 6 meter horizontal ) for stage ii , guard tube and guard plateremoval , fabrication and fitting , build up in eroded tubesas per requirement , repairing of skin casing , fabrication of bends of any degreeof any boiler tube , fitting and welding of tube attachmentwherever require , membrane strip fitting & welding , fabrication and erection of steel itemsby ms plate/ ms angle/ ms channel/ i beam etc . , boiler metal temp tc & mounting replace , thermowell replacement in hp line , gst ...
26501536 thermal annealing of glass preform using tube furnace supply , installation and commissioning of thermal annealing of glass preform using tube furnace , thermal annealing of glass preform using tube furnace , atmosphere control tube furnace , essential spare items : impervious high alumna process tube , essential spare items : heating element with connecting spring clips & braids , packing and forwarding , gst , charges for inland transportation , insurance , charges for installation , commissioning and training etc . , any other charges...
26204202 annual rate contract for maintenance of boiler pressure parts of stage i and stage ii , btps under b and a dept . , btps , wbpdcl annual rate contract for maintenance of boiler pressure parts of stage i and stage ii , btps under b and a dept . , btps , wbpdcl , maintenence of boiler pr . parts stage i unit capacity 60mwx2 , economiser tube joint tube od 51 mm , thickness 4 . 8 mm , material: sa 210 gr . c or equivalent , insert at furnace wall , goose neck s pannel & roof tube ( 1 insert = 02 nos . joint ) tube od: 63 . 5 mm to 69 . 9 mm , thickness from 5 . 1 to 6 . 3 mm , material: sa 210 gr . a or equivalent , joint at saturated screen roof & side wall , screen tube , primary superheater tube , secondary superheater tube . ( od: 63 . 5 mm , thickness: 5 mm upto 6 . 9 mm , material: sa213t11 or equivalnt ) , insert at furnace wall , goose neck s pannel & roof tube ( 1 insert = 02 nos . joint ) tube od: 63 . 5 mm to 69 . 9 mm , thickness from 5 . 1 to 6 . 3 mm , material: sa 210 gr . a or equivalent , joint at saturated screen roof & side wall , screen tube , primary superheater tube , secondary superheater tube . ( od: 63 . 5 mm , thickness: 5 mm upto 6 . 9 mm , material: sa213t11 or equivalnt ) , insert at furnace wall , goose neck s pannel & roof tube ( 1 insert = 02 nos . joint ) tube od: 63 . 5 mm to 69 . 9 mm , thickness from 5 . 1 to 6 . 3 mm , material: sa 210 gr . a or equivalent , joint at saturated screen roof & side wall , screen tube , primary superheater tube , secondary superheater tube . ( od: 63 . 5 mm , thickness: 5 mm upto 6 . 9 mm , material: sa213t11 or equivalnt ) , maintenence of boiler pr . parts stage ii unit capacity 215 mwx1 , lp water cleaning economizer zone , psh & prh , joint for lnsertion of water wall tube , cage rear wall below main cavity & baffle wall tube below main cavity , size: 63 . 5x5 . 4 , mat: bs3059 / 45s2 or 5a210gr . c , insertion joint for division wall tube size: 82 . 5x7 , mat: bs3059 / 45s2; or sa210gr . c , joint for lnsertion of furnace roof , cage rear wall & baffle wall tube above main cavity , size: 63 . 5x4 . 8 , mat: bs3059 / 620s2 or sa213t11 , joint for insertion of economiser tube size: 38 . 1x3 . 6 , mat: bs3o59 / 45s2 or sa210gr . c , insertion joint of psh bottom & middle size:57 . 1x6 , mat: bs3059 / 620s2 or sa213t11 , joint for insertion of psh top bank tube tube , size: 63 . 5x3 . 6 , mat: bs3059 / 33s2 or sa210gr . c , insertion joint of prh bottom & middle size: 57x3 . 2 , mat: bs3059 / 620s2 or sa213t11 , joint for lnsertion of prh top bank tube size: 57x3 . 2 , mat: bs3059 / 620s2 or sa213t11 , joint for lnsertion of plsh and fsh inlet tube , size: 44 . 5x7 , mat: sa213t22 , joint for lnsertion of fsh & frh tube size: 50 . 8x3 . 6 , mat: sa213t91 , economiser / psh / prh coil lifting , inspection repairing and fitting with proper alignment ( if required for preventive inspection beyond the leakage area ) , platen sh , fsh , frh coil pulling inspection and proper alignment of coil and panel with clit and support welding , second pass scaffolding per 6 meter , common work for stage i & ii , stress relieving , radiography , lremoval and refitting of refractory , replacement of high pressure valve size upto 2 , replacement of high pressure line ( 1 / 2 to 4 ) ( unit of 01 number includes two joints ) , deinsulation & insulation with cladding of wall , casing and pipe and other area of boiler , hp valve welding from 50 nb upto 100 nb pipe , hp valve gland packing replacement upto 6 , hp valve servicing including gland packing & bonnet seal replacement upto 4 , d metering of boiler tube at any area of boiler for thickness measurement ( minimum survey 150 nos . / day ) , minimum mobilization charge if total executed job value less than rs . 15000 . 00 , vertical scaffolding for approaching roof tube / wall reheater / mrh / platen / division panel ( per 6 meter vertical ) for stage i & for approaching furnace / roof tube / pendent reheater / platen / fsh & division panel ( per 6 meter vertical ) for stage ii , horizontal scaffolding for approaching platen sh / divisional wall / scw / roof tubes / furnace ( per 6 meter horizontal ) for stage i & for approaching rh / platen sh / final sh / divisional panel / scw / roof tubes / furnace ( per 6 meter horizontal ) for stage ii , guard tube and guard plate removal , fabrication and fitting , build up in eroded tubes as per requirement , repairing of skin casing , fabrication of bends of any degree of any boiler tube , fitting and welding of tube attachment wherever require , membrane strip fitting & welding , fabrication and erection of steel items by ms plate / ms angle / ms channel / i beam etc . , boiler metal temp tc & mounting replace , thermowell replacement in hp line , gst...
26034219 procurement of “1200°c split (tube) furnace to be attached to (existing) zwick utm (model no. z050 allround tc ii)”...
26034210 tender for “tube furnace...
26015414 supply 1200 degree celsius split ( tube ) furnace to be attached to ( existing ) zwick utm...
25906412 tender for two zone split tube furnace with accessories...
25813402 tender for supply of 1200°c split (tube) furnace to be attached to (existing) zwick utm (model no. z050 allround tc‐ii)in the materials science centre of iit kharagpur....
25798187 procurement of tube furnace...
25652056 supply of two zone split tube furnace with accessories...
25577570 supply of various scientific items equipment and chemicals 1 chamber furnace having maximum temperature ( 1300 degree c ) , 2 deionized water purification system ( detail as per tender document no iuc_cc / pur / 0299 3 freeze dryer used for sample drying with condenser temperature ( 80 degree c ) ( detail as per tender document no iuc_cc / pur / 0282a 4 horizontal tube furnace ( 1200 degree c ) ( detail as per tender document no iuc_cc / pur / 305 5 table top hydro thermal autoclave ( 100 ml. ) ( detail as per tender document no iuc_cc / pur / 0300 6 standard reference materials ( detail as per tender document no iuc_cc / pur / 303 7 high purity elements ( chemicals ) ( detail as per tender document no iuc_cc / pur / 302 8 high purity oxide materials ( chemicals ) ( detail as per tender document no iuc_cc / pur / 301 9 150 ah 12 v smf vrla batteries 30 nos. ( detail as per tender document no iuc_cc / pur / 0101 10 150 ah 12 v smf vrla batteries 60 nos ( detail as per tender document no iuc_cc / pur / 303...
25531695 procurement of pid controlled tube furnace with fittings and ss regulators. ...
25473057 horizontal tube furnace with controlled gas atmosphere supply , installation and commissioning of horizontal tube furnace with controlled gas atmosphere...
25183462 procurement of pid controlled tube furnace with fittings and ss regulators...
25111630 procurement of pid controlled tube furnace with fittings and ss regulators...
24239139 supply of two zone split tube furnace with accessories...
24016365 supply of two zone split tube furnace with accessories in the materials science centre...
22945179 supply of repair of three stack tube furnace...
22941331 supply of different cast parts for making pumps, magnetorheological damper, remi r bc centrifuge, tube furnace, desktop pro g2, hollow aerofoils, pitot tube holder, pressure sensor for direct pressure sensing from pipelines, repair and upgradation the existing wind turbine setup with generator for sustainable power application, diesel engine generator unit for existing downdraft gasifier for sustainable power, lab scale biogas up gradration unit for existing anaerobic digewster, biogas engine generator unit for existing anaerobic digester, data logger, repair/upgradation the existing anaerobic digester with automatic ph control unit, thermostatic temperature control unit...
22902578 supply of two zone split tube furnace with accessories...
22723365 supply, installation and commissioning of horizontal tube furnace with working temperature of 1600c and controlled gas atmosphere...
22700300 high temperature 1200 degree celsius split three zone gradient tube furnace for horizontal operation supply for high temperature 1200 degree celsius split three zone gradient tube furnace for horizontal operation , procurement of high temperature 1200 degree celsius split three zone gradient tube furnace for horizntal operatio . ( details of specification mention in tender document ) , packing and forwarding , gst , any other charges...
22562591 supply, installation and commissioning of horizontal tube furnace with working temperature of 1600c and controlled gas atmosphere...
22234816 two zone gradient tube furnace high temperature 1200 deg c split tube two zone gradient tube furnace for horizontal operation . ...
21987099 purchase of tube furnace...
20608745 supply of tube furnace=> open tender...
20528855 supply and installation of high temperature tube furnace, nit 01 / dst fist 17 / iserc / 19a...
20509831 tender for supply and installation of high temperature tube furnace => open tender...
20338344 tender for 1300 degree celsius split tube furnaces and controllers...