University Of Burdwan - West Bengal

37891798 tender for repairing of minor instruments bod shaker incubator/shaking incubator cold centrifuge (remi) ft ir power back up egg hatching incubator autoclave microtome colorimeter 20°c freezer bod incubators cold room (blue starmake) hot air oven water bath 80°c freezer laminar air flow incubator biosafety cabinet...

Bidhan Chandra Krishi Viswavidyalaya - West Bengal

33676305 purchase , particulars , atomic absorption spectrophotometer ( aas ) : atomicabsorptionspectrophotometerwithgraphitetubeautomizer ( gta ) , flameautomizer ( fa ) andvapourgenerationassembly ( vga ) , unitforflame ( airacetyleneandnitrousoxide acetylene ) , chiller, autosamplersforgtaandflame.: technical specification: atomic absorption spectrophotometer: computer controlled with built inflame emission mode, wave length range: 180 – 910nmwave length, sensitivity: sensitivityatleast0.35absfor5µg / mlaqueouscopperstandardsolutionwithair – acetylene flame., optics: double beamholographic monochromator, czerny turner , focallength: atleast250mmfocallength, resolution: 1800lines / mm, slit width: 0.1nm, 0.2nm, 0.4nm, 1nm, 2nm & 5.0nm ( six step auto changer ) , flame atomizer: alltitaniumor equivalentburnerwithimpactbead / flowspoiler, premixdesign, movement: automatic movementintothe sample compartment, affect from acids, organic solvent: unaffected from attacks by acid solution or organic solvents ( e.g. methylisobutylketone i.e. mibk, flame alignment in liquid beam:fullyautomatic, optimizedwithmotorizedburnermountforverticalandhorizontalburneradjustment, nebulizer:highprecisionabletoprovidemanuallyadjustableuptakeratesmaterialofthenebulizerandrelatedventurishouldbeinerttoacidsolutionsandorganic solventssuchasmibk, flame control: computercontrolledignition, gas control: computercontrolledwithoxidantandfuelgasesmonitoringtomonitorconstantfuel / oxidantrationignition., safety function: interlockingsystem to preventignition, essential interlock monitor: burnertypeaswellasitspresenceinposition, airselector, flamesensor, liquidtraplevel, gassupplypressureandairsupplyanywhere inthe networkofgastubings inthe system, automatic lamp selection function: computer controlled hollow cathode lamp selection and alignment, lamp holder: atleast8lampholderwithbuiltinpowersuppliesforhollowcathodelampsandelectrode–lessdischargelampsorequivalent, operating parameter setting: automatic setting, read out / display: displayfacilityforabsorbanceaswellasconcentration, displayoferrorsorerrorcodes, absorbancerangeat least upto 2.0 abs., scale expansion: scale expansionatleastupto 100x, integration time: integrationtime shouldcoveratleast0.1to 60 secondsrange, measurement: measurementsofmean, rsdandcv, backgroundonlymode, integration ofpeakheightandpeakareas.accessories / spares with flame aasystem, vapor generation assembly: shouldbecontinuousflowbasedhydride / mercuryvaporgeneratorwithoptionofusingwithorwithoutaprogra, mmable auto sampler highly automatic: after pressing the start key, the whole, process ( sampling, reacting, calibrating and cleaning ) will be, finished automatically.high sensitivity: the sensitivity of most elements is better than 1ng / ml / 1%a. sensitivity of arsenic is better than 0.15ng / ml / 1%a.rsd: less than 3% measurement time: the single measurement will take 25 to 35 sec, less solution: sample 2 2.5ml ( including clean ) , potassium, borohydride 1 1.5ml, carrier liquid 5 6ml.atomizer: heated absorption cell ( heated by air c2h2 flame in standard carrier gas: ar pressure: 0.32 mpa, consumption:70 ml / min, power requirements: 240 vac, 50 / 60 hz, precision: precisionofbetterthan oratleast1%atppblevelsofmercury, arsenic etc. absorption cell: theabsorptioncell’smaterialshouldhavenoeffectofthehighheatof the flame andthe cellforthe analysis ofmercuryshouldbeofa closedabsorptiondesign flame arrester: flamearrestershouldbeprovidedinthetubewhichconnectsthe assemblyto the absorptioncell, cell design holder: thedesignofthecellholdershouldgiveafirmandeasilyadjustable ( foralignment ) mountingonthe burnerhead. system accessories: complete withnecessary reagentbottles, connectorsetc.hollow cathode lamps: arsenic, antimony, calcium, chromium, cobalt, copper, iron, nickel, lead, manganese, mercury, tin, zinc, molybdenum. air compressor with air filter or equivalent air service unit:completewithpressureregulatorquiteinoperation, necessarytubingandconnectorsandshouldmeettheairsupplyrequirements of aasoperation.oil free pump: oil free pumpandmoisture trap, corrosion resistant: resistanttoacidic vapourandthedrainvalve ( if any ) shouldbemade of stainlesssteelof equivalentcorrosionresistantmaterial nitrous – oxide gas regulator: nitrousoxidegasregulator ( twostage ) withheater, withnecessarytubing’sandconnectors.necessarytransformershouldbeprovidedto transformthissupplyto therequirementsoftheheater.theheatershouldworkon230±10volts50hzacpowersupply.acetylene gas regulator: acetylene gasregulator ( twostage ) withnecessarytubingandconnectors.nitrogen gas regulator: nitrogenregulator ( twostage ) withnecessarytuningsandconnectors.graphite furnace system, graphite tubeatomizer: should becomputercontrolledfullyenclosedgraphitetubesystemconsistingofstabilizedtemperature / totalpyrolyticgraphite plateform.gassupplies: provisionoftwogassupplies ( programmeselectable ) withindependentcontroloverthe gassupplythroughthe furnace.heatingrate: heatingrate ofatleast2500°cpersecond coolingtime: coolingtime20seconds temperature range: temperaturerangeambientto 3800°cor morein 1°cincrementsfeedbacksystem: feedbacksystemforfurnacetemperaturecontrol, interlocksforwater, gas, temperature, furnacedoor, graphitetubedamage andmainspower.temp.programming upto 20 rdertemperatureprogrammingfacilitywithflexibilityofprogramselection, ramptime, gases, gasflowandreadtriggerforeachtemperature step.control computercontrolledwithappropriateprovisionforprintoutofthe furnace andsample parameters display calibrationdata / graphs, temperatureprofiles, signalgraphicsandthe instrumentstatus. memory memoryshouldbe ableto storeatleasttwenty fivenonvolatileprogrammes chiller cooling mode: compressor cooling, temperature controller: pid controller, temperature range: 5°c – 35°c, accuracy: ±1°c, cooling capacity: 1300w @25°c, pump pressure: =1.3bar, pump flow: =15litre / min, tank volume: 8 litre, tank material: stainless steel ss304, refrigerant: r134a size ( w*d*h ) : 360*450*653mm, power supply: ac220v, 50 / 60hz dataworkstation application softwareprogram facility with multitasking software shouldprovidecompletecontrolofinstrumentwithinstrumentstatusdisplayanditsvariousaccessories. provide accurate and reproducible time averaged, integration, non – averaged integration, multi level calibration. softwareshouldhandleinstrumentlinearabsorbancereading, concentration, oremissionintensity, integrationtime, built instatistics, calibrationequationcontrol, slopeofanalyticalcurveusingoperatorselectivecalibrationstandard built ininterfaceforcomputerconnectionanduseofoptionalaccessories. comprehensivequalitycontrolprotocolsfacilityincludingblank, multiplequalitycontrolstandards, qa / qcaudittrailandcalibrationfailure. computer system, make reputed brand, processor i5 10th gen, ram 8gb or advance.ssd 512, monitor 19”led, operation software: preloaded windows xp professional operating system with licensed cd or better msoffice2000standardwithmedia, manualandlicensedcdor better, preloaded antivirus with latest version along with licensed cd or better fume hoodexhaust fume hood made in stainless steel chimney with std 20ft ss304 powder coated exhaust pipe with inert centrifugal blower 1400rpm, ac 230v, with standard fitting installation hardware for installation. operation kit standardoperationkitincludingallrequireditems, tubings, fittingsforstartup / regularoperationofinstrumentsuchasgaspurificationsystem to be supplied with the system. operation / maintenance manual operation / maintenance manualforeachunit analytical manual analyticalmanualincludingapplicationsforflame, vgaandgraphite system operation and maintenance training one weektrainingto beprovidedtotwo scientiston softwaretraining, operation, maintenance andtrouble shootingaspectsof instrumentatthe timeof installation. , air conditioner : split ac with inverter swing compressor: streamer discharge & dew clean technology for healthy air capacity 1.5 ton: suitable for medium sized rooms ( 111 to 150 sq.ft ) 5 star: best in class efficiency copper condenser coil: better cooling and requires low maintenance key features cooling capacity @ 43°c: 100%; noise level: 38 db ( a ) ; ambient operation: 54°c special features: 15% higher iseer compared to base iseer ( 4.5 ) of 5 star ac; patented streamer discharge for healthy air; intelligent eye to adjust cooling according to human presence; triple display ( power consumption %age, set / room temperature & auto error code ) ; dew clean technology that cleans indoor unit coil with a press of button refrigerant gas: r32 environmental friendly no ozone depletion potential indoor unit, outdoor unit, remote control, user manual, warranty card & standard installation kit , bod incubator: floor standing, double doors .temperature range 5°c to 80°c with uniformity of ±0.2°c @ 10°c. microprocessor pid controller delivers superior temperature control accuracy, required for precise results. features and advantages include illumination lamp, caster wheels for easy mobility, digital timer . 175litres / 6.1cft, external chamber ms, internal chamber ss304, solid insulated door ( with glass & without glass ) w / lock door, stainless steel 5 shelves removable, caster wheels, humidity system, light system by interior illumination w / 3 fluorescent tubes, timer 0 99 hours for regulating cycles illumination condition, rfid enabled door locking system. brand name and model name must come in the display. , centrifuge: max speed: 15000 rpm speed accuracy : ±1rpm or ±1 x g temperature: 10°c to +40°c. possibility of precooling during standstill rotor type: angle rotor for conical centrifuge tubes. all rotors with lid and anti corrosion coating rotor capacity: 8 x 50 ml with max. rpm:~14000 rpm 8 x 15ml with max. rpm:~ 14, 000 pre selection of run parameters in terms of rpm timer range: pre selection of time from 30sec. to 10 hr. or continuous set time in hrs:min, min:sec, or continuous mode automatic rotor identification & imbalance sensor low vibration during the operation. extremely low noise during operation ( <66 db ) . with microcontroller for speed, time and temperature motorized lid lock and inter lock keys for start, stop and lid open power supply: 230 v / 50 60 hz , chns analyser : fully automated pc controlled elemental analyser for solid and liquid samples.the analyzer must be able to simultaneously determine the elements in the following combinations: chns, or chn, or cns, or cn, or nwithout a need to change column helium as carrier gas and option for argon as carrier gas in chns mode.sample weight range: 0.2 mg of organic compound to 800 mg or more inhomogeneous soildetection range: 0 to 100% for all elements ( c, h, n, s ) with the capability of measuringat least 10 mg absolute carbon in chns mode and more than 50 mg in cn mode standard deviation: ?0.1% of absolute. lower detection limit of < 50 ppm for n , c and s with thermal conductivity detector ( tcd ) dependingon sample weight. the instrument must fulfil the international and national safety standards. for safety reasons, theentire instrument including furnaces must internally operate on low voltage ( < 50 v ) . large dynamic measurement, range from 0.1 milligram, chemical substance to1 gram inhomogeneous soil, best analysis results for any sample matrix, wide variety of optional configurations, individually extendible, low and tool free maintenance, low noise level, low total cost of ownership, integrated 120 position auto sampler as standard, patented ball valve forblank free sample transfer. furnace system • should have two zone furnace system, separate for combustion and reduction with independent temperature control for each furnace in chns mode. easy slide out mechanism of furnace for routine maintenance work. it should be possible to set difference temperature for combustion and reduction. • controlled furnace temperature should be 1200 deg c or more. • easy ash removal without change of combustion tube by means of an exchangeable ash crucible. separation system • combustion gases in the form co2, h2o, n2 and so2 are separated by means of single temperature programmed desorption ( tpd ) column. detector system • oxygen intrusion free thermistor technology based temperature stabilized tcd detector for measurement of c h n s o auto sampler system • integrated 50 or more position automatic sampler having capacity to handle upto 1000 mg sample in each sampler holder position of carousel software • should be windows based and should have operating software with automatic calculation and statistical evaluation of sample results, automatic leak check, sleep / wakeup function, gas stop, service and maintenance support and weight transfer from external balance. • all instrument functions incl. gas flow and pressures must be digitally controlled for diagnosis and trouble shooting via the internet. consumables: to be supplied with consumables enough for 1, 000 sample analysis in chns / cns mode. necessary documents: • catalogue in original. • all technical specifications should be printed on the manufacturers catalogue / data sheet. , compound microscope : compound microscope ( 10x eye piece, objective with magnifying powers 10x, 40x and 100x oil immersion objective lens ( body monocular die cast body, inclinable upto a horizontal position ( 90° ) ; focussing by coarse & fine focusing knobs; eyepieces huygenian 10x and 15x; objectives hard anti reflection coated, colour coded par focal achromatic 10x, 40x, 100x, oil immersion; condenser built in sub stage condenser with iris diaphragm. branded, best quality ) , compoundtrinocular microscope with camera: trinocular head, eyepiece: swf 10x, u plan objectives of 4x, 10x, 40x and 100x, abbe 1.25 n. a. condenser with iris diaphragm, ceramic coated flat top stage, co axial coarse and fine focusing, led or halogen illumination with automatic voltage sending power supply, digital camera ( 5 mega pixels ) , fire wire cable, c mount adapter 0.7x and image analysis software with 4d experiment ability. , conductivity bridge : advanced microprocessor based design. brand name and model name must come in the display. conductivity and tds modes. automatic and manual temperature compensation auto ranging. 0 20?s / cm, 20 200?s / cm, 200 2000?s / cm, 2 – 20 ms / cm, 20 200 ms / cm, 200ms / cm 2000. multi point calibration. tds conversion factor from 0.40 to 1.00 cell constant adjustable from 0.1 to 10.0 temperature coefficient adjustable from 0 to 10% / °c normalisation temperature adjustable from 15 to 30 °c. bi directional rs232 interface. baud rate selectable from 1200, 2400, 4800 and9600. single and continuous print out of conductivity. multiple printout types. combinations selectable from sr. no., cond / tds, date, time and temperature. real time clock. temperature setting ( manual temperature compensation ) . calibration report as per glp requirements lcd touch screen display with backlight. memory storage of 100 measurements. data logging facility up to 500 results. data logging interval selectable from 5s, 10s, 20s, 30s, 1m, 2m and 5m. temperature calibration. , compound phase contrast binocular microscope : body: binocular, sturdy, stable base body with focus adjustment controls. eye piece: paired, high quality, achromatic, wide field, system complete with illumination system is required. objective: three objectives 10x, 40x, 100x. 10x and 40x objectives should have numerical apertures of 0.25 and 0.65 respectively.100x should have numerical aperture of 1.65. nose piece: revolving nose piece to accommodate a minimum of three objectives with click stops. it should be provided with ribbed grip for easy rotation mounted on a precision ball bearing mechanism for smooth and accurate alignment. stage uniformly horizontal, mechanical stage having dimensions of length 140 mm ( + / 20mm ) . the stage should be provided with spring loaded slide holder for exact positioning of specimen / slide. the stage should have ball bearing arrangement to allow smooth travel in transverse directions i.e. 80 mm ( + / 10mm ) and front to back direction, 50mm ( + / 10mm ) . the system should have a build in variable light source ( illuminator ) . this light sourceshould have a 50 w, 12 v halogen lamp. all consumables required for installation and standardization of system and microscopecover to be given free of cost. , desktop computer with accessories : corei5 11400 motherboard gigabyte h510mh , 16 gb ddr4 ram, 512 ssd, key board, mouse, 19”led colour monitor, bluetooth, cabinet, branded laser printer. , digestion hood for the laboratory : internal lining: suitable material for hf resistancelike upvc or pp internal size ( 1600x675x1250 mm : wxdxh ) ± 10%should supply with digital face velocity meter withalarm / low exhaust indicatorcold water service fixture ( inlet and outlet, pre plumbed ) for using distillationunit inside. tri wall construction for maximum robustness. u pvc / pp internal chamber. chain and sprocket sash support system. hood lighting is pre wired. lighting is electronically ballasted, energy efficient, instant start. typical light intensity on work surface is >1076 lux in zero ambient conditions. u pvc exhaust collar ensures superior chemical resistance. one gas service fixture pre plumbed internal electrical connection: two number ( 5 / 15 amp ) socket internal light fitting for proper illumination with external switches vertical sash: polycarbonate / toughened float glass ( acidresistant ) removable baffle / suitable mechanism for easycleaning, blower and duct: pp+frp – 250 mm diameter duct 20 feet in length 1 hp motor and reputed and standard company ( brand must be mentioned ) , 600 cfm minimum volume weather proof pp / motor housing. exhaust: pp+frp exhaust fan with chemical resistantimpeller system will be installed in first floor of laboratory block. stack height should beat least three meters above top roof ( two storey building ) shaping vanes increase airflow “sweep” at the critical area atthe sidewall to improve containment, especially when laboratorypersonnel walk fast in front of the hood. , electronic precession balance : maximum capacity [ max ] 200 / 2000 g minimum load 20 mg, readability [ d ] , 0.001 / 0.01 g tare range 2000 g, repeatability ( max ) 0.001 / 0.01 g repeatability ( 5% max ) 0.0005 / 0.005 g, linearity±0.002 / 0.02 g stabilization time2 / 1.5 s adjustment external physical parameters levelling system manual display lcd ( backlit ) delivery components balance, weighing pan, weighing pan shield, grounding foot ×1, foot ×3, power supply. weighing pan dimensions 128×128 mm packaging dimensions 470×380×336 mm net weight 3.2 kg gross weight 4.8 kg, protection class ip 43 , communication interface communication interface, 2×rs232¹, usb a, usb b, wi fi® ( option ) electrical parameters, power supply , adapter: 100 240v ac 50 / 60hz 0.6a; 12v dc 1.2a balance: 12 – 15v dc 0.4a max , environmental conditions operating temperature +10 — +40 °c. , environmental shaker :environment shaking incubator : salient features , programmable logic controller ( plc ) , 4.3 hmi with colour display and touch screen, password protected operation. , universal platform to accommodate vanous type of flask and test tube rack max ( 8x250ml ) .electronic capacitance type humidity sensor , direct display of temperature and humidity, display of set value and process value, unique air flow system ensures even distribution of temperature and humidity, precise control of temperature and humidity by using built in pid controller ( auto tuning type ) , forward and backward rotation programs and rpm 30 350, maintenance free brushless induction motor, variable frequency drive ( vfd ) permanently lubricated bearing for noise less operation, triple eccentric counter balanced drive mechanism for uniform agitation, castor wheel for ease of mobility adjustable levelling jack. , horizontal autoclave : 1.fully automatic micro processor based high pressure, high vacuum autoclave for sterilizing material including agars, sterilization of solution in open & closed bottles, disinfection of materials and waste decontamination. 2. should be front loading, have rectangular, horizontal chamber with well insulated jacket, chamber volume minimum 165 lit. 3. should have single vertical sliding door to have a pass through system. door should be electrically controlled having fully automatic function with multiple safety arrangements. sealing system should be based on silicone seal.4. should have at least 50mm thick insulation materials on jacket and in doors to ensure low thermal losses. working temp. of the door should be less than 45deg. c. 5. should be high grade stainless steel.6. should have a built in colousr touch screen.7. should have audio visual alarms in case of undesired situations. 8. should have programmable operators access level. 9. should have at least 10 pre programmed standard cycles plus 5 or more user programmable cycles and provision of chip card port for loading of new programs through chip cards.10. should have temperature adjustable from 25deg. to 135 deg. c. 11. safe working pressure range should be adjustable 12. should have complete monitoring of cycle operation and provided with at least two pressuresensors and two temp. sensors ( pt 100 ) in addition to analog for chamber pressure, jacket pressure and steam generator pressure indication.13. the unit should be equipped with multiple safety mechanisms for emergency stop over pressure safety valves for chamber and jacket, over temp safety, steam traps and electrical safety.14. the unit should include non fade built in thermo recorder for step progress values during the cycle with time and date and alarm condition if any.15. should have built in feature of water saving system for water conservation.16. should be supplied complete with high quality stainless steel trolleys and sterilization baskets: a. external trolley = 01 nos.b. internal trolley with steel roller c. shelves = 01 nos. and d. 2 sets of sterilization baskets. 17. all accessories & electric fitting to be included 18. three compulsory visits for calibration and check up irrespective of complaints in year.19. the steam generator should be also be made of aisi 316 ti steel & the steam generator should be equipped with automatic cleaning facility. 20. integrated waste water cooling, integrated water saving device. touch screen display, chip card reader and rs 232 interface. , hot air oven : capacity 250 litre, temp range: +5ºc to 250ºc. control accuracy: ±0.2ºc, uniformity: ± 2.0 at 100.0ºc minimum 3 no. of shelves with height adjustable in 25mm steps, glass window in built into the door for easy viewing of samples, automatic cut off of heater & blower when door opened, digital pid temperature controller with timer, alarms and auto tuning, aero dynamic internal design for achieving horizontal air circulation, solid and plain bottom without electrical, outer body made of g.i epoxy coated inner body made of stainless steel with clear bottom ce certified. brand name and model name must come in the display. , hot plate : size 420 x 320 x 130 mm ht. ( total height with feet ) weight 9 kg, voltage 230v ( 50hz ) , temperature 250°c maximum uniformity + / 2°c.temperature rise 6°c per minute temperature drop 1°c per minute, the hot plate should be able to control the temperature within + / 2°c, temperature should be uniform throughout the hot plate surface. 6. there should be rims around the edges of the hot plate for safety, power 2200 w, approx. 9.6 amp in 230v, material pfa coated graphite. , laminar air flow chamber : microprocessor controlled system with motorised door. type of airflow: horizontal full password protected operation. 70% of air should be recirculated to the cabinet work area through hepa filter and the 30% balance should be exhausted through hepa. the balance should be dynamic to ensure the 70 / 30 recirculation / exhaust air the instrument must have hepa filters on down flow as well as exhaust with an efficacy of 99.99% for particles sized of calibration certificates along with dop test report shall have to be submitted at the time of supply of instrument ) the dimensions of the working chamber should be in the following range: length: 90 120 cm , width: 40 60 cm , height: 50 80 cm . the main body and working chamber of the cabinet should be made of stainless steel, rigid and rustproof with removable trays the cabinet should have an electrically operated sliding front sash made of safety ( uv ) glass with a provision for manual operation of the sliding front window. also, the sliding front sash should have true air and aerosol tight electrical shahs. front door: clear transparent sturdy material work chamber should be fitted with a fluorescent lamp for illumination and should have programmable uv light cycle. the unit should have microprocessor control keys with large icons and a large graphical display with provision for the permanent display of the following key cabinet conditions. i. inflow and down flow air velocity ii. exhaust and recirculated airflow volumes iii. time and date iv. residual lifetime of filters & total time of cabinet operation ( optional ) alarm notification in the following situations: i. low inflow velocity ii. low down flow air velocity iii. hepa filter life iv. alarms for clogged filters v. other malfunction compatible at a power supply of 220 v, 50hz noise level: < 65 db basic cabinet should be termite and insect resistant and washable accessories: manometer, gas inlet, castors the cabinet should be with a stand with lockable castors brand name and model name must come in the display. , multimeter with ion selective electrodes for water quality testing : colour capacitive touch screen with software control facility. can store 2000 sets of test data, which can be saved and transferred to usb memory stick and opened with excel. power: universal ac adapter and with rechargeable lithium battery ( included ) . concentration range: ( 0~19990 ) , can switch 6 kind of concentration units: ug / l, mg / l, g / l, mol / l, mmol / l, ppm. concentration resolution: 4 significant digits ( expressed in scientific notation ) can be operated through 5 amp plug and battery. accuracy: ±0.1mv or 0.03% temp range: ( 0? to 100? ) accuracy: ±0.1? output through usb / bluetooth battery life 1000 hour. type: lithium battery. ise fluoride, chloride , bromide, ammonia, brand name and model name must come in the display. , mechanical shaker: compact bench top microcontroller based shaker with temperature control range from ambient +5°c to 60°c , ergonomicallydesignedwithminimalfootprint triple eccentriccounterbalanceddriveforuniformagitationwith 25mmshakingorbitmaintenance freepermanent ( self ) lubricatedshieldballbearingsfornoiselessoperationfrpexteriorwithanti vibrationmountforsmoothrunning preciseshaking speedcontrolwithgentlestart / stopcycle, preventingspillagepowerfulpermanentmagnetdcdrivewithdigitalleddisplayofspeed pulsewidthmodulation ( pwm ) basedspeedcontroloptionaltimerfunctionforspeed autore starttosetspeedafterpoweroutage universalplatformtoaccommodateerlenmeyer, roundbottom, volumetricflasks, testtube holdersµplateholders hasautorestartfunctionafterpowerinterruptionwithnonvolatilememory ( retainsetparametersafterpowerfailure ) orbital shaking with orbit diameter of 25 mm, speed 20 450 rpm with accuracy of ± 2 rpm, led display , universal platform and clamps to hold flaskscapacity 100ml 64nos or 1000ml. 16nos, tray dimension : 450 x 450 mm, noiseless operation, operational voltage 220 ± 20v, 50 hz, should meet ce standards , mechanical soil auger : soil auger sampler : made of iron : screw type, one meter long with handle :size : 2.5 cm. dia , microprocessor based flame photometer : alphanumeric graphics lcd ( 240x 128 dots ) brand name and model name must come in the display microcontroller based na, k, li, ca& ba auto ignition gas leak sensor auto gas cut off. pass word protection. separate logging for guest and administrator quadratic curve fitting rtc high quality compressor software na minimum concentration without dilution 2 ppm and 0 200 meq / l with 1:100 dilution ba can be measured upto 3000ppm without dilution in higher concentration mode and 500ppm at lower concentration mode. caupto 250 meq / l with 1;100 dilution bandwidth 10nm curve fitting accuracy ±2% f.s pc link software to send data to pc. gas cylinder and regulator must be supplied. product must be ce certified and company should bear iso certification. brand name and model name must come in the display. , microtomy : section thickness range: 0.25 60 ?m trimming thickness range: 5 500 ?m resolution: 0.25 for 0.25 1 ?m 0.5 for 1 5 ?m 1 for 5 20 ?m 2 for 20 30 ?m 5 for 30 60 ?m resolution: 5 for 5 10 ?m 10 for 10 100 ?m 20 for 100 200 ?m 50 for 200 500 ?m knife carrier retraction during return travel of the specimen: 60 ?m horizontal feed range of the knife carrier: max. 28mm vertical specimen stoke: max. 64mm specimen size: 55 x 50 mm specimen orientation: x and y axes: universal 8º z axis: up to 360º , microwave digestion system : large furnace cavity design with completely independent intellectualproperty rights, 1~6 100ml ultra high pressure digestion tanks can be placed at the same time; industrial grade 1000w magnetron. temperature and pressure dual measurement and control, precise control, active prevention of over temperature and over pressure, maximum working pressure: 6mpa, maximum withstand temperature: 300°c, maximum working temperature: 250°c high precision anti interference pressure sensor adopts double explosion proof control mode to directly measure the actual reaction pressure in the digestion tank, the pressure measurement range is 0~10mpa, and the pressure measurement accuracy is 0.01mpa; insert high sensitivity platinum resistance temperature sensor, directlymeasure the actual reaction temperature in the digestion tank, the temperature range is 0~300°c, and the temperature measurement accuracy is ±0.1°c; it can measure and control the pressure and temperature in any reactiontank, and the 7 inch high definition camera display accurately shows the chemical reaction process; equipped with perfluorination digestion tank or ft double layer digestion tank: ptfe digestion tank is made of ptfe ( polytetrafluoroethylene ) , and the sheath is made of high strength explosion proof aerospace composite. the fiber material is made by one time die casting, high temperature resistance, high pressure and strong acid corrosion resistance; easy disassembly and assembly, fast cooling; double venting protection and digestion tank for venting holes and sealed bowls; up to 6 ultra high pressure digestion tanks can be placed at the same time; the furnace cavity is ventilated with acid resistance, large air volume centrifugal fan, and the exhaust air volume is 5m3 / min; specially designed self locking ground moving safety door to resist accidental explosion and microwave leakage. tank technical parameters: the pressure resistant jacket material is a hydrophobic high strength pressure resistant composite fiber material, which is explosion proof and supports washing and easy to clean. the inner tank adopts imported modified polytetrafluoroethylene ( tfm ) , high strength frame type closed ultra high pressure reaction tank: the highest withstand temperature =300 °c. explosion proof membrane automatic pressure relief and peek compressionmodule pressure relief safety design to ensure the safe operation of the instrument. the whole tank pressure monitoring system, the threshold value can beadjusted. using high strength engineering plastics for one injection molding, independent ultra high pressure digestion tank holder. tank 6pcs, power ac220v / 50hz / 10a, microwave frequency 2450 ( mhz ) , microwave output power 1000 ( w ) , microwave cavity 45 ( l ) , protective spraying pfa, control heating method pid, temperature ramp 1~50? / min, cooling time =25min, microwave leakage =0.3mw / cm2, temperature control range 0~300?, temperature control accuracy 0.1?, pressure control range 0~10mpa, pressure accuracy 0.01mpa, outer tank material peek, inner can material tfm1700, highest temperature resistance 300?, operating temperature 250?, highest pressure 15mpa , microwave oven : convection microwave oven with ceramic enamel cavity 21l ( 1. capacity: 0.7 cu.ft. / 21 ltr., 2. heat source: convection 3. power: power consumption ( microwave ) 4.1200w 5. power source: 230v / 50hz 6. output power ( max ) : 2350w 7. powerlevel:6 8. display type: led bar 9. control method: membrane 10. door opening type: handle 11. microwave distribution: turntable 12. cavity interior :ceramic enamel ) , millipore water purifier : parameter value or range pressure 2 – 6 bar flow rate > 10 l / min at 2 bar feed water type potable water temperature 5 – 35 °c conductivity 10 – 2000 ?s / cm at 25 °c ph 4 – 10 hardness ( as caco3 ) < 300 ppm silica concentration <30 ppm carbon dioxide concentration ( co2 ) < 30 ppm langelier saturation index ( lsi ) < 0.3 fouling index ( fi5 ) or silt density index ( sdi ) = 7 ( * ) total organic carbon ( toc ) < 1 ppm free chlorine < 1.5 ppm typical water quality measures with a well designed and maintained distribution loop of 20 meters: flow rate pressure 5 lpm / 1.32 gpm 2.2 bar / 32 psi 15 lpm / 3.96 gpm 1.9 bar / 28 psi20 lpm / 5.28 gpm 1.6 bar / 23 psi plumbing connections inlet ( feed water connection ) 3 / 4 bsp loop start / return 1 1 / 2 sanitary tc drains 3 / 8” lab water purification systems type 2 ( pure ) , muffle furnace : controller: should be microprocessor based & at least 8 segment programmable or equivalent controller with necessary safety features. programmable temperature ( pid controller ) controller with heating rate control from 10?c / min to 40?c / min. ( fast heating rate would be preferable ) , heating element :kanthal a1 and backed by high temperature ceramic insulation , safety: over temperature protection& over load protection ( safety controller ) should provided. door safety switch must be provided so that it disconnects power supply to heating element when door opens. should be equipped with digital over temperature protection circuit to fail safe in the event of a controller malfunction , critical electronics component and heating elements protected by a 35a circuit breaker., weight : less than 100 kg , two set of operation and maintenance manual should provided. , ph meter : supply of bench top, digital ph meter along with all its accessories and spares required brand name and model name must come in the display. to operate the instrument as per specification given below: the direct reading laboratory ph meter ( digital ) operable at 230v + / 10v a.c., 50 hz powersupply with necessary cable connections and other standard accessories required for smoothoperation. measuring range resolution accuracy ph range 0 to 14 ph ( min. ) 0.001 ph ± 0.002 ph mv 1000.0 1000.0 ( min. ) 0.1 ph ± 0.2, rel. mv 1000.0 1000.0 ( min. ) 0.1 ph ± 0.2 temperature mtc 10.0 100.0 °c ( min. ) 0.1 °c ± 0.1 °c, temperature atc 5.0 100.0 °c ( min. ) 0.1 °c ± 0.1 °c, temperature compensation : it should have both automatic and manual temperaturecompensation touch screen display , parameters likeph, temperature, mv, date & time etc. ingress protection level : it should be ip54 complied protection level.power requirements : it should be operable with 9 12v / 10w dc adapter. storage of instrument : it should be able to stored in temperature of 5 to 40 °c and relative humidity of 5 to 80% ( non condensing ) glp compliance : it should be glp complied .to improve the reproducibility, it should allow to choose from at least three endpoint criteriaaccording to our requirements.the electrode holder should move in a perfectly vertical way, making it easy to place the sensor in the perfect position i.e. vertically in the measurement beaker. it should be able to connect peripherals via usb and rs232, increasing its possibilitiessignificantly. export of measurement data and calibration data should be possible to usb stickto direct pc software whenever required by us. it should allow monitoring of limits of parameter ph by giving a warning message when the value falls below or exceeds the predefined limits. it should have facility not to delete of data and changing of settings in routine mode. hence it required to be pin protected for login, deletion of data, system settings etc. it should have choice of endpoint formats like automatic, manual and timed. it should have choice of ph decimal places like x.y, x.yy & x.yyy ( up to one, two andthree decimal places. ) it should have data storage up to 1000 measurements ( min. ) it should have ph sensor input through bnc connector with impedance of more than 3 x 1012o . it should have temperature sensor input. it should be able to show the quality of last calibration on its screen. , precision drier : capacity, material and construction: cap:3ltr / h evaporation rate. suitable for aqueous feed solution. laboratory scale model. external body –ss316. drying chamber and cyclone in full ss 316l construction. total construct size: 1200 x 1300 x 2000 mm ( ±10% dimesional tolerance ) , self supported on castor / wheels ( compressor size is extra ) . weight: max 130 kg ( ±20% ) ( compressor weight is extra ) chamber: chamber size: diameter 280 350mm, length 600 1000 mm, with conical bottom. feed pump: variable speed gearless peristaltic pump with dual teflon rollers and precise speed control. feed pump should be of repute make preferable watson marlow / miclin / flowtec or equivalent. silicon tube for feed. pump should be controlled through plc and manually as well. spray system and nozzle:moc for two fluid spray nozzle: 316l variable aperture nozzle of 0.7mm.other sizes such as 0.5 / 1.0 / 1.2 / 1.5 / 2.0 / 2.5 mm may be available. auto de blocking system for spray nozzle which will be fitted on nozzle controlled through a de blocker timer. an additional spray aperture for future use should be included. nozzle geometry and design must be submitted with a tender document. desired output particle size range 20 45 micron, compatible with ceramic slurry also. controller and display: plc based operating system with a multi touch colour, interface, 9” hmi with data logging, online trends, recipe functionand ability to store recipes and recall for ease of use. plc of repute make such as siemens, delta or equivalent etc. thesystem should have an audio visual alarm for a. inlet temperature, outlet temperature and atomization pressure. thesystem should have parameter control and safety interlock. inlet / input air temperature / / temperature range: ambient to minimum 260 degrees c, variable and selectable aspirator airflow:max. 150 cum 3 / hr with vfd for motor control of repute make such as delta, fuji or equivalent air heater:electrical heater with minimum 6.0kw capacity inlet filter:combination type ( pre + hepa ) for pre filtering environment air to keep most impurities and particles away from the spray drying process, outer filter assembly: mainly to protect aspirators from fine particles. it should include spun bound polyester cartridge with ptfe coating. efficiency 1micron down to 99.99%.compressor: oil free air compressor piston type with min. 20l air reservoir 1hp power supply: single phase, compatible with indian standard , quartzdouble distilled water plant: all quartz, material of distillation unit shall be made of high purity electronic grade transparent quartz only, heaters: demountable boiler panel with compact design of boilers & condensers easily mountable for cleaning and maintenance with spiral heaters, electrical requirement: 230 250 volts 10 / 50hz, single phase, dist. water output capacity ( ltr / hr ) : 2.5 ltrs / hr, total power consumed 4.4 kw, conductivity ( ?s / cm ) : <1*10 6, distillation units type vertical, biological activity pyrogen free, double stage glass ( quartz ) distillation units yes, double wall condenser quartz, cooling water consumption ( ltr / hr ) 2 ltrs / min, boiler quartz, demountable model and should be connected with rubber tumbling and pinch cock for cleaning sediments in primary boilers and must be ce / iso certified.primary boiler provided with o ring accessories distillation apparatus power supply ( daps ) : the unit provides for automatic working of distillation unit by switching off the heaters in case water level falls below the heating coil, there by safeguarding the heaters. the unit resumes distillation when water level is restored. the unit also comes with buzzer. apart from the above features, dual cut off: the dual , quartz single distilled water plant: all quartz, material of distillation unit shall be made of high purity electronic grade transparent quartz only, heaters: demountable boiler panel with compact design of boilers & condensers easily mountable for cleaning and maintenance with spiral heaters, electrical requirement: 230 250 volts 10 / 50hz, single phase, dist. water output capacity ( ltr / hr ) : 2.5 ltrs / hr, total power consumed 2.2 kw, conductivity ( ?s / cm ) : <1*10 6, distillation units type vertical, biological activity pyrogen free, single stage glass ( quartz ) distillation units yes, double wall condenser quartz, cooling water consumption ( ltr / hr ) 1 ltrs / min, boiler quartz, demountable model and should be connected with rubber tumbling and pinch cock for cleaning sediments in primary boilers and must be ce / iso certified. distillation apparatus power supply ( daps ) : the unit provides for automatic working of distillation unit by switching off the heaters in case water level falls below the heating coil, there by safeguarding the heaters. the unit resumes distillation when water level is restored. the unit also comes with buzzer. apart from the above features, dual cut off: the dual cut off switches off the heater even when there is no cooling water supply to the condenser. , refrigerator : frost free refrigerator : auto defrost function to prevent ice build up capacity 253 ltrs : suitable for small families and bachelors | freezer capacity: 69 ltrs fresh food capacity: 184 ltrs digital inverter compressor – enjoy greater energy efficiency, less noise and a long lasting performance. it automatically adjusts its speed in response to cooling demand shelf type: spill proof toughened glass shelves with easy slide special features: easy slide shelf, door alarm, inverter, temperature control, cool pack, stabilizer free operation ( 100 ~ 300 v ) key feature : all round cooling for even cooling corner to corner | power cool enjoy rapid cooling performance | moistfresh zone preserve the freshness and flavor of fruit and vegetables for longer | interior led light | moveable ice maker | tall bottle guards | recess door handle | fresh room | deodorizer | r600a refrigerant , refrigerator temperature control : the upright freezer type comes with an abs make interior. its outer body is a painted steel board, the door comes with a handle and a safety lock on it, there are casters provided for easy handing, its inner drawers are made of plastic control system : uses a microprocessor based temperature controller • the temperature control range is adjustable between 10°c to 20°c • it has a digital temperature display, equipped with audio such as: high or low temperature alarm, chamber volume 270ltr, chamber dimensions 800x500x500 outer dimension 1060x695x792 input voltage 230vac 50hz , semi automatic nitrogen protein analyzer : analyzer should be semiautomatic system consisting of a digestion unit, a scrubber unit, and a distillation unit. digestion unit: automated with integrated programmable control, should have electrically heated ( 230 ± 10 volts, 50 hz ac ) metal blocks. it should be capable of providing a temperature range from 100°c 440°c with ±10°c repeatability. should have inbuilt temperature controller with digital display and led display along with manual temperature adjustment. heating time setting with steps from 1 150 minutes should have the capacity to accommodate at least eight numbers of digestion tubes each of at least 250ml capacity , should have leak proof integrated condensers ( fumes carriers ) made up of glass, fixed on a movable panel along with adopter for outlet to the scrubber unit. proper digestion exhausts system. scrubber unit should be an oil free centrifugal suction type, with manual vacuum adjustment facility. corrosion and impact resistant provided with condensate and acid fumes collection vessels. should operate on 230 ± 10 volts, 50 hz, ac power supply. distillation unit fully programmable distillation unit including sample dilution, alkali and receiver addition, distillation and tube draining facility. validated procedure / certification for tkn distillation like aoac, epa, din, iso etc, should be made up of standard quality borosilicate glass. should possess a steam generator made up of borosilicate glass along with heater and have 3 step manual control facility i.e. standby, water inlet and distillation. should have inbuilt bellows pump for accurate reagent ( alkali / acid ) dispensing. should have ventilation valve. should have timer for 5 15 minutes with audio signal. steam inlet tube should be of ptfe. unit should have quick clamping device for digestion tube with adaptor. should operate on 230 ± 10 volts, 50 hz, ac power supply. complete unit shouldprovided with one set of digestion tubes along with the servicing, operating and maintenance manuals. can able to monitor and measurement of distillate temperature. self adjusting cooling water control facility safe feature for safe distillation. can be upgradeable whenever required accessories: 2 set of digestion tubes, digestion tube stand, spillage tray for the condensers, tube removing device , soxhlet’s apparatus : body constructed in ms epoxy coated finish , featuring use of mantle type heaters that comes with support of energy regulator, capability to handle 6 tests, can handle flasks of 250ml capacity, supplied withsupport of clamps as well as rubber tubing, works on electric supply of 220 / 230 volts, 50 / 60 hz ac, suitable to heat soxhlet flasks of 250ml , top loading balance: maximum capacity ( or ) range of the balance80 90 / 220 gm readability 0.01 mg ( 0.00001 gm ) / 0.1 mg ( 0.0001 gm ) tarring range 0 – 220 gm display backlit graphics display / lcd with touch screen operation. repeatability ( standard deviation ) 0.03 mg ( small range ) / 0.10 mg ( large range ) , linearity ±0.20 mg / ±0.10 mg, eccentric load 0.30 mg, calibration adjustment with internal weights, fully automatic calibration technology with temperature controlled, data memory function for keeping weighing data & calibration history data, 10 sensitivity drift ±2ppm / °c ( when automatic self calibration is not used ) stabilization ( typical and fast ) approx. 4.0 sec ( 0.1mg ) / 15 sec ( 0.01mg ) , size of weighing pan ~ 80 90 mm, shielding glass draft shield with flexible configuration protective cover for the terminal, replaceable feed through for weighing below the balance, power supply to be operable with 230 v ac, 50 hz power supply. accessories power supply cable with all accessories for operation, operating & service manual 2 sets ( of hard copies ) with calibration certificate of the balance. soft copy of instrument operating manual to be sent during the time of installation, interface standard bi directional rs 232 interface, dust cover one. , ups for the laboratory : 10kva 192v 8kw online ups , 16nos external battery module with iron rack, ups / automatic bypass facility, true double conversion online ups, microprocessor control for higher reliability. pure sine wave.input power factor correction. wide input voltage range ( 110 v – 300 v ) . generator compatible, selectable charging current allows flexibility to add any battery size, emergency power off , uv visible spectrophotometer : double beam ( 185 1100nm ) spectrophotometer with standalone colour lcd display with pc controlling software optical system: double beam, diffraction grating minimum 1800 lines / mm, scan speed :6000nm / min, 8 position sample holder, photometric details range must cover from 4 to + 4, bandwidth variable ( 0.2nm 6nm ) stray light < 0.05% t @ 220, 340 ( must cover less than 370nm ) , baseline flatness must cover + 0.006a, detector photodiode / single photodiodes / dual silicon photodiodes, power 240+ 10%, 50 60 hz, light source xenon flash lamp, wavelength details , accuracy must cover 1.0nm, measuring modes absorbance, transmittance ( % ) , concentration, operating modes: single wavelength, multiple wavelength, time scan, data presentation display analysis results and graphic data on screen, pc link software, port to data transfer, supplier should provide service for installation, demonstration, training for all operation procedure, temperature range operating conditions should cover +10 degree c to 40 degree, analytical quality assurance instrument should have internal quality assurance tools, certification must comply ce certificate. accessories: quartz cuvettes: 50mm length, 10mm, 20mm path length ( each 2 pairs ) , original catalogue to be enclosed. dedicated branded pc to be quoted with the system .should have manufacturer’s service centre in west bengal and details location to be mentioned in the quotation.. , vertical autoclave : quality systems for medical devices built: • floor standing vertical type top loading autoclave • outer dimensions: width 75 87 cm; height 90 110 cm; depth 65 80 cm software control:• fully microprocessor based proportional integral differential ( pid ) pressure control• controller and software should comply with international standards such as 21 cfr part 11 or any other equivalent.• should have facility to store identification codes and password codes for access level control• built –in memory to store number of cycles sensors:• should have in built platinum resistance temperature detector with a typical resistance of 100 o at 0°c that complies with international standards of safety requirements for electric equipment for measurement control and laboratory use, eg. iec61010 1, iec 61010 2 040 • option to connect additional temperature sensors and pressure sensors should be available display:• user interface should: • be easy to operate• have digital display enabling visualization of stage of the cycle, set and process temperature, pressure and quick access to important information • preferably have graphical display of temperature and pressure• have notification for replacement of filters after appropriate number of runs performed. chamber volume: should be not less than 100 litres and preferably should be 150 180 litres in capacity. suitable number of basket for bottle, vessels or agar media preparation should be quoted along with the instrument.chamber material: should be long lasting, made up of 316ti grade stainless steel of asme / ul grade chamber pressure: chamber should be designed to withstand at least 2.8bar / 142°c and should meet, european pressure equipment directive ( ped 97 / 23 / ec ) .2 | 2 chamber heating: should be heated uniformly by a heating plate on the outer wall with heater of suitable wattage for quick heating.chamber insulation: chamber should be completely insulated with chloride free glass wool. sterilization temperature range: 105°c to 137°c with accuracy of ± 0.1 deg c at 121 deg c & an additional isothermal temperature range of 60°c to 105°c. should have feature minimizes the time liquids are exposed to high temperatures during sterilization thereby protecting liquid media, saving laboratory time and reducing energy consumption. biohazard and waste management system: should have the facility to filter air removed from chamber before sterilization that isuseful for sterilization of biohazard waste.safety: • water level monitoring and maintenance of constant level for safety of heaters. • a safety device to prevent opening the door when the chamber is pressurized. • prevent starting of runs if doors are improperly locked.• safety feature should allow opening of doors only when the temperature reaches a pre set temperature and pressure reaches atmospheric pressure.power requirement: a suitable size of electrical switch gear 3 phase 440 volt with earthing andrecommended size of current capacity mccb will be made available on wall at appropriate place. other connection and installation has to be done by the supplier. , hydrometer , keen boxes , aluminium box , brass sieve , mortar and pestle , different types of augers: , screw type , post hole type , dutch type , stirrera. magnetic b. electric , khurpi , electric heater , room thermometer , gps machine , camera , lcd projector...

Bidhan Chandra Krishi Viswavidyalaya - West Bengal

33667096 establishment of state of art soil water testing facility and service centre purchase goods , particulars , milliporewater purifier: the system should produce pure grade water directly from potable water feed. the system, delivering astm type i and iii water, can be directly connected to the available potable water supply. system should contain inbuilt prefiltration containing 0.5um filter, silver impregnated activated carbon ( to avoid bacterial growth ) and polyphosphate granules anti scaling compound for removal of hardness from feed water. system should include reverse osmosis with conductivity sensors before and after the membrane to ensure the quality of purification. reverse osmosis should have a maximum water recovery of upto 20%. • total no. of conductivity cells in the system : four units • 3 – way solenoid valve : 2 units • ro reject recovery loop available to minimize tap water usage. recovery upto 66%. • rfid tag for automatic traceability of new consumables in the system’s memory to ensure on time reordering of the pre treatment consumables, the system should have automatic warnings and alarms regarding the water quality.type iii product water quality:, ions rejection : 97 to 98 % with new ro cartridge., organics rejection : > 99 % for mw > 200 dalton, particulates & bacteriarejection : > 99 %., flow rate : 8 lt / hr. the system should be quoted with proper prefilter & iron removal filter. both of these have to be provided by the same company who manufactures the water system.prefiltration system:a two stage purification 5 micron and 1 micron polypropylene graded density wrapped type depth filter with low voltage 20 watts powered dc pump with noise levels of 50 db prefilter should be attached with tap water. and• the unit shall comprise of diaphragm pump with inter connections and built in pressure sensor ensuring continuous monitoring of cartridge life.• system shall operate at minimum inlet pressure of 0.5 bar and maximum of 1 bar. • system shall deliver water at the outlet at a minimum pressure of 2.6 bar till a maximum of 2.8 bar.• system can handle feed water with tds as high as 5000 ppm and sdi upto 50.• it protects the water purification system downstream. iron removal filter:the system is connected with back wash able iron removal filter to deliver 0.1 ppm out put. feed water quality : potable tap water, conductivity :< 2000 ?s / cm., ph : 4 10, total chlorine : < 3ppm.fouling index : < 12., feed water toc : < 2000 ppb pe reservoir with vent filter: blow moulded pe reservoir with 50 l capacity with sensor rod float switch with a vent filter to resist airborne contamination consisting with 0.65 micron filter, activated carbon and sodalime for the removal of particulates, co2, n2 etc.the system produces type i water suitable for molecular biology, pcr, hplc & other critical applications. type igrade product waterspecifications: resistivity:18.2meg ohm.cm ( @ 25 degree c ) , toc : < 5 ppb , bacteria :< 0.1 cfu / ml , pyrogen : <0.001eu / ml, flow rate : 2 l / min, particulates> 0.22u:<1 p / ml , rnase: <0.01 ng / ml, dnase: 4 pg / ul company must provide ce, cul, valid iso and certificate of conformity. warranty for a period of 12 months from the date of installation. the system contains a built in dual wavelength photooxidation uv lamp ( 185 & 254 nm ) . the lifetime of uv lamp is two years. to support lifetime of uv lamp, original literature from company is to be submitted without fail.there must be minimum 200 systems installations in & around kolkata at leading depts. of state govt. institute, central govt. research institutes, industry in west bengal.and company’s own service team must be based in kolkata. engineers should be well trained by the company itself on water purification system. they only provide service whenever needed. suitable filters should be included wherever required. suitable distribution pump, booster pump for pumping feed water to the main unit from storage tank. final filter is 0.22 un. prefiltration cartridges are to be supplied for one year. in case, the system is having patented technologies in it, certificate with patent details should be submitted for proprietary item. systems consumables traceability via rfid tag technology. all water purification cartridges and point of use filters will have a built in rfid tag to ensure proper installation location, note installation date, and track volumes of water passed through the purification element. supporting documents wherever required and original catalogue should be provided to validate specifications. to verify the above technical specification provided catalogue & flow schematic must match on their global website for quoted model. , microwave digestionsystem : microwave digestionsystem capable of simultaneous processing of multi reaction vessels for digestion all kind of samples using all types’ acids including hf through pressure active control on reference vessel with pressure rate increase control and direct temperature control on all vessels. loading of vessels: top loading with hardware and software safety interlocks. sample vessels should be inserted individually from top for easy sample access. cavity and lid : stainless steel construction with heat bonded fluoropolymer ( pfa perfluoro alkoxy ) coating. system control and interface : touchscreen control, inbuiltsoftware, memory formethodparametersanddigestiondata with usb interface, software: built in software featuring screen display of temperature, weight, method search, power profile, method set up, cook book methods for various matrices, graphic display of routine operations etc. system should have option to operate using pc. software should have separate user login and admin login to secure method developed. digestion vessels: • vessels should bemadefrommassive tfm or ptfe tfm for easy handling.• the rotor should have capacity of 16or more vessels to run samples in same batch / run.• volume of vessel should be 75ml or more• vessel operating pressure should be high up to 100 bar or better• vessel operating temperature should be up to 2600 c or more. microwave oven: • the system should have poweroutput of1500w or more using dual magnetrons 2000w from 2 magnetrons ( 2 x 1000w ) • system should have circularoven forhomogeneousirradiation with pfa coating for corrosionprotection &gas collectionsystemforprotectionfrom reactiongases. • built in integrated cooling system for removal of gases ( vapours ) and cooling of vessel without a use of external chiller / thermostat in less than 20 minutes, reaction control:• the system must have direct temperature control in real time, measures the actual sample temperature in each individual vessel quipped with floor mounted ir sensors.• the system should pressurecontrolsensor for reference vesselinrealtime.• the temperature and pressure sensors supplied should be maintenance freewithoutcable connections. temperature measurement: measurementrangeambient to 250oc or more, pressure measurement : measurementrange0 to 40bar or better, contact free, optical sample pressure measurement, safety features : • interlocks to avoid opening of vessels during hot condition • release of over pressure to protect vessels from damage. • the system must have automaticsafety shut down atoverheat / overpressure. safety and emc emissions compliance warranty details: one year standard on site warranty from date of installation , input power supply: 230 240 v, 50 / 60 hz , centrifuge machine : microprocessor research centrifuges … • centrifuge rotors & carriers are suitable for use with variety of falcon & vacutainer tubes, • soft touch keypads for fast and accurate setting of run parameters. basic runs are easy with setting of speed, time, temperature, brake, press start key and compufuge • brushless induction motor with frequency drive & unique automatic rotor identification ensuring accurate speed setting for individual rotors. over current overheating safety cutoff circuit is provided for motor protection. • safety lid interlock on the centrifuge ensuring that the rotor does not run with lid open while the lid cannot be opened unless rotor comes complete halt. • max. speed 20000 • max. rcf 37540 • max. tube size 100 • max. capacity 400 • w x d x h ( mm ) 400 x 500 x 440 essential features: • user friendly microprocessor control with led display • menu driven ten programme memory • choice of high brake, low brake and coasting • imbalance detector with auto cutoff • safety lid interlock to prevent cover opening during centrifugation • automatic unique safety rotor identification system • speed holding accuracy 100 rpm • self diagnosis for errors four ( 4 ) years on site warranty from the date of installation iso 9001 2015 certified , environmental shaker : orbital shaking incubators salient features: • brushless induction motor with variable frequency drives suitable for continuous operations• step less variable frequency drive ensures gentle shaking start and maintains set speed• counter balanced mechanism for high stability in uneven load of different sized flasks• universal shaking platform to accommodate different sized assorted flasks• maximum shaking capacity – 9 flasks x 2000 ml• powerful fan motor for forced air circulation to maintain uniform conditions inside chamber • machine filled cfc free puf insulation to eliminate void pockets• unique design of thermal barrier for better energy efficiency• heating by long ss tubular heaters• additional tray to store samples• chamber calibration port on side • hermetically sealed compressor with cfc free refrigerant ( cis 24 plus ) • microprocessor controller with 4” lcd display for display of shaking speed & temperature• 9 programes memory• high temperature safety cut off & alarms for high / low set temperature• electrical circuit breaker• time delay for compressor switch on ( cis 24 plus ) • overload cut off relay for compressor ( cis 24 plus ) • rounded inner chamber for easy cleaning• attractive door profile• weight carrying capacity of each tray : 30 kg uniformly distributed• auto door closer• smart handle with led door closure indication• four ( 4 ) years on site warranty from the date of installation, desirable features: ( i ) touch screen display ( tft ) with additional features ( ii ) validation protocol with iq, oq, pq documentation ( iii ) port for calibration probes / safety back up iso 9001 2015 certified temperature range & accuracy: 5 c to 60 c + 0.5 c, internal volume ( liters ) : 215, platform size: 580mm x 600mm, maximum shaking capacity ( volume x no. of flasks ) : 100ml x 49, 150 ml x 33, 500ml x 24, 1000ml x 15, 2000 ml x 9, shaking speed range ( rpm ) : 20 to 250, shaking ampiltude: 25 mm, internal dimensions w x d x h ( mm ) : 660 x 765 x 650, external dimensions w x d x h ( mm ) : 800 x 1150 x 1300, temperature control: microprocessor with pt 100 sensor, display: 4 lcd screen, large size display for ease of reading, power failure alarm: audio visual alarm, door open alarm: audio alarm in case door open for over one minute, temperature variation alarm: set temperature + 2 c, audio visual alarm, illumination: 8 watts fluorescent tube, internal body material: stainless steel 304 grade ( standard modelas ) , stainless steel 316 grade ( gmp models ) , external body material: power coated crca steel ( standard models ) , satinless steel – 304 grade ( gmp models ) , insulation ( cfc free polyurethane foam ) : 70 mm minimum for body & 80 mm for door, noise level: less than 65 db ( a ) , recommended voltage stabilizer : vs02, warranty: four ( 4 ) years on site warranty from the date of installation , precision drier: microprocessor control helps in achieving precise high temperature with forced convection. • technical specifications ( parameter wise ) • internal dimension ( w × d × h mm ) 450×400×450 • chamber volume ( litres ) 740×618×630 • temperature range rt+10 ~300 c • temperature accuracy 1 c • display resolution ±1 c • timing range 1~9999min • shelves ( nos ) 2 • power consumption 1550w • electrical requirements 220v, 50hz, single phase essential features • microprocessor pid controller ( with timing function ) • polished stainless steel chamber with rounded corners for easy & quick cleaning • uniform distribution of air temperature • forced air convection • double layer glass door, larger viewing window four ( 4 ) years on site warranty from the date of installation iso 9001 2015 certified , 20 kva onlineups with battery back up:src 6000 uxi capacity 200kva, battery bank consists of 32nos, battery rake, 100 ah vrla battery exide, 120 minutes back up, 3 years warranty , uv vis spectrophotometer: microprocessor based uv vis spectrophotometer with high resolution touchscreen display, for operation on 220v / 50hz. ? uv vis spectrophotometer should have operating wavelength range 190nm to 1100 along with on board software for instrument operation. ? the software should be offered with user friendly software to work in scanning, wavelength program, time drive, rate, quant, scanning quant modes ? spectral bandwidth should be variable from 0.5, 1, 2, 5 & 20 nm is preferred ? fully optically double beam with czerny – turner monochromator design and holographic grating of 1200 lines / mm with 0.2 m focal length is preferred. ? light source : deuterium & tungsten ? detector – silicon diodes is preferred ? scan speed : up to 12000 nm / min or more ? wavelength accuracy : ± 0.1 nm or better is desirable ? wavelength reproducibility : ± 0.1 nm or better ? a stray light of <0.01 %t 220, 340 & 370 is a must ? photometric noise should be less than 0.00005a or better ? photometric range : minimum ± 4 a or more ? photometric accuracy should be ± 0.002a or better ? photometric reproducibility : ± 0.001 abs or better ? baseline stability should be less than 0.0003 abs / h or better ? cell ( quartz ) – with stopper – volume – 3.5 ml. – pack of 2 to be supplied along with instrument ? high sensitivity matched pair silicon photodiode detector ? 4 usb ports or more for high speed pc and printer connectivity, data storage and transfer through usb pen drive ? the instrument should provide network access via wireless connectivity. data can be transferred to a pc via a network ? large sample compartment compatible with wide range of accessories. ? must supply one pair of 10mm path length quartz cuvettes of 3.5 ml volume as a standard supply ? the instrument must be under 3 years on site warranty from the date of installation the following must be supplied along with the main instrument: ? one branded i3 pc with original windows 10 professional ? one laserjet printer online 1 kva ups with 30 minutes back up , automaticnitrogen protein analyzer: a. speed digester with scrubber digester unit, digestion system for 6 sample tubes with adjustable ir –heating and tight suction module to prevent the escape of sulfuric acid vapors during digestion. robust design with stand alone tube holder made from stainless steel. complete and ready to use system supplied with the following: • heating levels 1 to 10 and ir heating up to 580 °c • the insulation tube as well as the optimal designed heating chamber guarantees that the sample tubes are heated with optimal thermal homogeneity • sample tubes 300 ml ( diameter 48 mm ) with constricted condensation zone, glass thickness of 2.3 mm for sample tubes • tight suction module with included hose for scrubber / water jet pump.• stand alone rack• water jet pump, plastic• fast heat transfer; temperature range 700c to 580 c • sample holding capacity: at least 6 nos with 300 ml• tight suction module to prevent the escape of sulfuric acid vapors during digestion.scrubber unit environmentally friendly neutralization and exhaust of aggressive fumes, which arise during kjeldahl or other digestions.the system should have following features • it should operate without water jet pump • the build in membrane pump should guarantee high suction performance of 32 l / min. • for more sensitive digestions the suction capacity can be adjusted in a typical range of 100 – 400 mbar below atmospheric pressure.• the two step gas scrubbing system consists of a 3 l neutralization step and an adsorption step • the scrubber should be supplied complete and ready to use. b. automatic distillation system with ph acid base titration the system should have following features • detection range of 0.02 – 200 mg / n or more• steam ramps should be available• naoh pump• h20 pump• 7 inch touch display, the intuitive touch screen provides fast feedback and enables easy process handling.• recovery nitrogen:n: >98% with digestion process, n: >99.5% w / o digestionprocess • integrated timer • distillation capacity ( 100% ) ~ 40 ml / min• efficient steam distillation by high performance steam generator. adjustable distillation power 10 100% • operating convenience: compact, modern, and functional design, stand alone unit using minimal space, easy to use keyboard, clear led display• tap water consumption ~ 1.2 l / min• system should store memory of 80+ methods • system should store number of determinations log• system should store number of determination results• steam performance 150 ml / 5 min, system should have safety features:• protection of users from burns at the splash protector ( distillation area ) , which is hot during distillation due to protective door.• prevention of the start of a distillation with the protective door open and stop a running distillation and the dosing of reagents immediately when the protective door is opened during the process due to protective door sensor.• prevention of the start of a distillation without a sample tube inserted due to sample tube sensor.• prevention of electrical shock during maintenance with service door sensor / switch to disconnect electrical power immediately when the service door is opened.• protection of glass parts by protective shield ( cover ) at condenser control:• full process visibility, visual control, and close monitoring of the distillation process through glass splash protector.• full visibility of dosing pumps. • distillation area should be visible to make method development or trouble shooting easier. • warranty : 4 years on site from the date of installation ( for whole set up ) should have proof of supply of atleast 3 fully automatic system with inbuilt titration.iso 9001 2015 certified , quartz water double distillation set : flow rate: 2.5 lit / hr, primary & secondary boiler: demountable quartz boiler with silicone o ring arrangement to separate primary boiler from secondary boiler, easy to drain: unit has drain outlet at bottom of primary boiler for removing sediments, tubing: silicone tubing 10mmidx14mm od, 10m long, power required: 4.4kw, 230v, microbial activity : pyrogen free, conductivity: conductivity < 1?s / cm, condenser: quartz condenser inlet & outlet are at top for easy maintenance also additional cooling condenser is provided at centre, o / p: 2.5lit / hr, lxbxh cm: 35x35x100, daps: auto cut off has buzzer function & reset button, third party test reports: govt testing certificate for moc / third party test reports for output water can be shared, moc: quartz boiler and quartz condensers, daps: auto off in case water level falls – works with level sensor, water leveller: sediment drain provision with pinch cock and water leveller are connected with “t joint” with primary boiler, warranty documents: 3 years on site warranty from the date of installation iso 9001 2015 certified , ph ec ion meterwith ionselectiveelectrodes: specification for benchtop ion meter with ammonium & nitrate electrode package: meter specification: ise range: 0.0001 to 19900 ; resolution: up to 3 significant digits ; accuracy: ± 0.2 mv ; units: ppm, m, mg / l, %, ppb, none; calibration points: up to 5 points; calibration edit: yes calibration feature: fix calibration errors without complete recalibration; temperature compensation: 5 to 105 ?c temperature resolution: 0.1; readout:backlit graphic lcd display; splash proof rating:ip 54 data logging point: 2000 data with date & time st power input: 220 vlt ac wall adapter / optional battery operated facility. stirrer : automatic stirrer probe facility directly controlled by the meter. warranty: 3 years replacement warranty. certification: ce & tuv, ise specification: ammonium electrode: plastic membrane half cell with reference electrode ; range: 0.01 to 17000ppm; temp range: 0 to 40°c nitrate: module based half cell with reference electrode, range: 0.1 to 14000 ppm as n temp range: 0 to40°c connector: bnc supply should include: supply should include main benchtop ion meter with electrode holder & stand, nitrate electrode with replaceable module, reference electrode, respective filling solution pack, 300 ml , nitrate 1000 ppm standard, suppressor solution for ground water sample & isa solution for surface water sample.and ammonium half cell electrode with reference double junction electrode and all their respective filling solutions; standards and isa solutions along with automatic stirrer probe buffer solutions for measuring 1000 samples must be supplied along with electrode warranty: 4 years on site warranty from the date of installation . certification: ce & tuv ise specification: ammonium electrode: plastic membrane half cell with reference electrode ; range: 0.01 to 17000ppm; temp range: 0 to 40°c nitrate: module based half cell with reference electrode, range: 0.1 to 14000 ppm as n temp range: 0 to40°c connector: bnc .supply should include: supply should include main benchtop ion meter with electrode holder & stand, nitrate electrode with replaceable module, reference electrode, respective filling solution pack, 300 ml , nitrate 1000 ppm standard, suppressor solution for ground water sample & isa solution for surface water sample.and ammonium half cell electrode with reference double junction electrode and all their respective filling solutions; standards and isa solutions along with automatic stirrer probe specification for benchtop ph / conductivity / tds / salinity meter: ph range: 2.000 to 20.000; ph resolution :0.001ph accuracy: ± 0.002 ;mv range:±2000.0 mv; calibration features:fix calibration errors without a complete recalibration;ph electrode type :ph / atc triode. conductivity range:0.001 ?s to 3000 ms; conductivity resolution / accuracy:0.001 ?s / 0.5% of reading ±1 digit for conductivity, tds & resistivity; compatible cell constant:0.001 to 199.9; ph / cond. calibration points:up to 5 points; cond. electrode type:dura probe conductivity cell;resistivity range / resolution:2 ohm to 100 meg – ohm / 2 ohms cm resolution; salinity range / resolution:0.01 to 42 ppt sea water / 0.01 resolution; tdsrange / resolution :0 to 200 ppt / 4 significant digits; tds factor range:linear, 0.01 to 10.00; stirrer provision ( optional ) :direct control of stirrer probe with meter. ip rating:ip 54 rated; data logging:2000 with date and time stamp including auto read function; power supply:universal, ac power adapter, 100 240 vacand 4 nos. aas battery ( 800 hrs. ) . warranty: 3 years replacement warranty , certification : ce & tuv , laboratory petty mechanical / heating devices a ) magnetic stirrer: • speeds range 150 1500 rpm • stainless steel hot plate model for temperatures up to 340 c• ceramic hot plate model for temperatures up to 500 c • easy to read backlit lcd for display of set & actual parameters • monitoring of set & actual temperature / speed• high accuracy of temperature control with embedded duel sensors• advanced stirrers with microprocessor technology• constant speed even with change of load / voltage • maintenance free brushless motor• scratch proof & excellent chemical resistance• external temperature probe for control of fluid temperature• last parameter recall, ideal for repetitive processes• unique safety temperature control system • settable safe temperature limit to avoid overheating• residual temperature warning when unit is switched off for operator safety• power 1050• max. stirring quantity ( water ) ( liters ) 10• stirring paddle ( ptfe coated ) q 20a ( 13 x 50mm ) • motor rating input ( w ) 18• motor rating output ( w ) 10• speed range ( rpm ) 150 1500• speed / temperature display lcd• speed display resolution ( rpm ) 1• top plate material ceramic glass• dimension of top plate ( mm ) 184 x 184• heating power ( w ) 1000 • temperature range upto 500 c• control accuracy of heating temperature 1 c• residual heating warning alarm above 50 c• control accuracy of heating temperature with pt 1000 0.2 c• external temperature sensor pt 1000• dimension ( wxdxh ) ( mm ) 360 x 215 x 112• protection class acc. to din en60529 ip 21warranty: 4 years on site warranty from the date of installation.b ) water bath: • multipurpose water bath with adjustable double line 12 holes to hold different size• samples for easy & hygienic heating. technical data with parameter • temperature range rt + 5 c _ 99 c• temperature stability +0.5 c• tracking alarm +2 c• chamber volume 15 ltrs• interior dimension ( w x d x h mm ) 450x300x110• timing range 1~9999min • remark double lines six holes• electrical requirements 220v, 50hz, single phase• power consumption 1500w essential features:• microprocessor control with timing function• digital display• audible and visual alarm for over temperaturewarranty: 4 years on site warranty from the date of installation. c ) willy mill grinder: • ¼ hp, chamber size 40mmx25mm ( cast steel chamber ) d ) microwave oven • convection, microwave, 28l capacity, 1400w e ) e burette: fully motorized, touch screen control panel, , pre calibrated dispensing speed, capacity 50ml, ptfe piston for good chemical compatibility, spring less valve assembly, inbuilt memory dor 20 reading, computer connectivity option with free software, rechargeable battery, 5 no. adapters free of cost, free spare usb cable for computer connectivity, battery charger, increment for 10ml capacity : 0.005 ml 25 ml capacity : 0.01 ml 50 ml capacity : 0.01 ml accuracy ( +, ) 0.2% cv ( +, ) 0.07% two years warranty , nabl certificate , refrigerator : frost free refrigerator with a capacity of 415 liters, double door, smart inverter with multi storage basket with an energy rating of 4 stars or better, 3 years warranty , ac machine : split type , capacity of ac units in tonnage 1.5 with 5 star rating, !00% copper, 3 years warranty , flame photometer: microcontroller based unit designed to provide automation in operation, measurements and end result presentation. it can do the estimation of sodium ( na ) , potassium ( k ) , lithium ( li ) , calcium ( ca ) and barium ( ba ) in single aspiration of a sample. specifications • microcontroller controlled automation for ease of operation.• determination up to five elements with single aspiration ( na, k, li, ca & ba ) .• unit of measurement “ppm” and “meq / l” • suitable for medical and industrial analysis• calibration standard up to five point.• auto ignition• gas leak sensor• auto gas cut off• password protection• separate login for administrator and guest• data processing with linear mode or quadratic curve fitting• results of a measurement taken earlier can be recalled and displayed ( max. results storage: 500 ) • graphics lcd readout ( 240 x 128 dot ) lcd readout for adequate user interfaces. • built in real time clock for date and time.• centronix printer port for epson compatible dot matrix / inkjet printers to get hard copy of results ( printer optional ) .• air compressor with built in air regulator and air filter ( systronics model 126 ) .• pc link software ( optional ) • reproducibility: + 1% fs + 2 digits in low concentration mode. + 2% fs + 2 digit in high concentration mode.• curve fitting accuracy : + 2% fs. ( high conc. range ) • filters ( regular ) : na ( 589 nm ) , k ( 768 nm ) ; interference filters with 10 nm bandwidth• filters ( optional ) : li ( 671 nm ) , ca ( 622 nm ) , ba ( 554 nm ) interference filters with 10 nm bandwidth• separate channel and separate silicon photodiode ( detector ) for each element.• minimum sample: approx. 3ml. • aspiration time: five element analysis within 20 second on single aspiration• operating air pressure: 0.45kg / cm2 ( typical ) , regulated. *• fuel gas: lpg ( liquid petroleum gas ) , regulated.**• power supply: 230v +10%, 50hz.4 years on site warranty from the date of installation elements minimum concentration without dilution maximum concentration ( without dilution ) low concentration mode maximum concentration ( without dilution ) high concentration mode na 0.2 ppm 10ppm 100 ppm, k 0.1 ppm 10ppm 100 ppm, ca 3.0 ppm 100 ppm 300 ppm, li 0.1 ppm 2 ppm 50ppm, ba 50 ppm500 ( minimum ) • minimum & maximum are the limit of calibration , not measuring range elements serum urine bio fluids na 0 200 meq / l, 1 : 100 dilution 0 250 meq / l, 1 : 100 dilution upto 250meq / l , with 1:100 dilution, k 0 10 meq / l, 1 : 100 dilution 0 100 meq / l, 1 : 1000 dilution upto 250 meq / l, with 1: 100 dilution, ca ( note ) 0 10 meq / l, 1 : 2 dilution upto 250 meq / l , with 1: 100 dilution, li 0 2 meq / l, 1 : 10 dilution upto 250 meq / l, with 1: 100 dilution specification for compressor • pressure : power supply : • to 1.0 kg / cm2 ( maximum ) 230 v + 10 % • weight : 6 kg ( approx. ) , digestion chamber with heating: specification of digestion chamber 1 dimension:1800mm x 1000mmx 1200mm ( l x b x h ) , working space:1500mm x 900mm ( l x b ) 2 fume chamber should be made of double skin construction of frp ( fibreglass re inforcement plastic ) , outside should besmooth finished and inside of fume chamber is mat finished.inner lining of the f.c. should be compressed frp sheet, lined with f.r.pof 5mm thick biphenyl a grade fume rate resin. 3 external finish will be with 1st class grade pigment with resign 4 conceal type counter balancing door with toughened glass with frp framing 5 casing of the blower should be made up from frp. motor wattage 0.75kw, 415v, 3000 / 1420rpm, tefc , type mn – 16 dol 415v, 3phase on / off push bottom starter 6 standard ducting system of 200 mm dia ( 8” ) . pvc rigid duct.10 m duct free with the system. 7 impeller of the blower should be made up from frp. 8 surface of the fume chamber also made fromfrp , also the working surface is fire retardant . 9 the fume chamber will have facilities to mount 02 no. service panel with external control to operate the gas, water outlet within the chamber, electric switches, 08watt led daylight fitted inside the chamber. specification of digestion chamber fume purification system water scrubber : vertical types: 1. size of the water scrubber is1000x 800x 1400 ( lx d x h ) . 2. frp make water tank of capacity 750ltrs. 2 nos. 3. chemical pump, capacity 85 lpm, h.p. 0.5 1no. all plumbing work from connecting point. ( source of water ) specification of hot plate 1.rectangular in shape. body is fabricated out of thick mild steel duly finished in white powder coating paint with mat finished colour combination. the hot plate made of cast iron precisely machined and smoothed duly finished in heat resistant black paint is firmly mounted on the body. heavy duty heating elements are securely laid under the plate to operate on 220 volts, ac , 50 hz . temperature is controlled by three heat rotary switch / energy regulator as per demand. sizes : 36” x 18” guarantee / warrantee for all components: 24 months from the date of installation...

Uttar Banga Krishi Viswavidyalaya - West Bengal

33604004 supply and installation of high precision equipment under rkvy infrastructure development at regional research stations , supply and installation of equipment / instruments , imported vertical autoclave 80 lit , imported laminar air flow , elisa reader , pcr machine , gel documentation system , gel electrophoresis unit with power pack , stereo zoom microscope , flame photometer , muffle furnace , refrigerated centrifuge , precision analytical balance , ph meter , refrigerator 250 265 lit , microoven 30 lit , all quartz vertical double distillation unit 2.5 lph with water softner & daps , high precision hot wate bath , magnetic stirrer with hot plate , imported orbital shaking incubator...

Department of Higher Education - West Bengal

33603991 supply of laboratory instruments in the department of botany under raiganj university. , supply of laboratory instruments in the department of botany. , automated thermal cycler ( dual block pcr machine ) detail technical specification ( soq ) separately appended. , bacteriological incubator ( approx 200 ltres capacity ) detail technical specification ( soq ) separately appended. , bod incubator ( approx 200 250 litres capacity ) detail technical specification ( soq ) separately appended. , bench top refrigerated centrifuge with pre cooling detail technical specification ( soq ) separately appended. , uv visible spectrophotometer detail technical specification ( soq ) separately appended. , ultra low deep freezer detail technical specification ( soq ) separately appended. , double distillation plant minimum 2 litres output per hour detail technical specification ( soq ) separately appended. , bench top orbital shaking incubator detail technical specification ( soq ) separately appended. , phase contrast hd inverted binocular microscope detail technical specification ( soq ) separately appended. , trinocular microscope detail technical specification ( soq ) separately appended. , semi automated rotary microtome detail technical specification ( soq ) separately appended. , uv transilluminator detail technical specification ( soq ) separately appended. , digital p h meter with electrode for water and soil analysis detail technical specification ( soq ) separately appended. , analytical balances digital ( specificity 0.0001g ) detail technical specification ( soq ) separately appended. , vertical gel electrophoresis chamber detail technical specification ( soq ) separately appended. , horizontal gel electrophoresis chamber detail technical specification ( soq ) separately appended. , power pack for gel electrophoresis system detail technical specification ( soq ) separately appended. , probe sonicator detail technical specification ( soq ) separately appended. , water bath with circulator detail technical specification ( soq ) separately appended....

Department of Higher Education - West Bengal

31428074 supply of chemical and glasswares , chemicals 1 rotary evaporator system with vacuum pump, controller and circulating chiller 2 gel documentation system with camera attachment 3 orbital shaking incubator 4 bod incubator 5 thermal cycler 6 compound microscopes 7 desktop 8 ups 9 laserjet printer...

Department of Higher Education - West Bengal

31427619 supply of equipments with specifications for purchase under boost category , supply, installation, testing and commissioning of equipments under boost category , rotary evaporator system with vacuum pump, controller and circulating chiller [ thermo scientific ] ( as per annexture ) , gel documentation system with camera attachment [ bio rad ] , orbital shaking incubator ( as per annexture ) , bod incubator [ remi ] , thermal cycler ( as per annexture ) , compound microscopes [ labomed ] , desktop ( as per annexture ) , ups ( as per annexture ) , laserjet printer ( as per annexture ) ...

Presidency University - West Bengal

31009633 supply of various instruments 1.01 0o2 incubator 1.02 multipurpose refrigerated centrifuge 1.03 shaking incubator with refrigeration...

Presidency University - West Bengal

30613847 supply of various instruments , equipment , co2 incubator for details specfication please reffer annexure iiii , bsl2 biosafety cabinet for details specfication please reffer annexure iii , cell culture centrifuge for details specfication please reffer annexure iii , multipurpose refrigerated centrifuge for details specfication please reffer annexure iii , shaking incubator with refrigeration for details specfication please reffer annexure iii , minus 86°c freezer for details specfication please reffer annexure iii...

Uttar Banga Krishi Viswavidyalaya - West Bengal

28151183 supply and installation of high precision equipment instruments under rkvy establishment of a state of art centre for detection characterization and farmer advisory for nematode and plant viruses , supply and installation of equipment instrument , supply and installation of pcr machine , supply and installation of gel documentation system , supply and installation of vertical gel electrophoresis unit with 300v power pack , supply and installation of precision analytical balance , supply and installation of ultra low ( 86c ) freezer , supply and installation of table top centrifuge , supply and installation of florescent spectrophotometer , supply and installation of ultra pure water purification system , supply and installation of important orbital shaking incubator...

University Of Calcutta - West Bengal

26821363 supply of laboratory instrument remi orbital shaking incubator shaking capacity upto 18 liters, temp. range 5ºc to 60ºc(without flask holding clamps)...

Uttar Banga Krishi Viswavidyalaya - West Bengal

26601871 supply and installation high precision equipment instruments under rkvy establishment of soil testing laboratory , supply and installation of equipment instrument , supply and installation of water softner , supply and installation of precision analytical balance : 0 . 1mg 220gms , supply and installation of biosafety hood , supply and installation of bod shaking incubator with cooling facility ( imported ) ...

Department of Higher Education - West Bengal

25368820 supply and installation of instruments at nabadwip vidyasagar college , nabadwip , nadia supply of instruments 1. item1 micro microscope 2. item2 simple microscope 3. item3 compound microscope 4. item4 hot plate 5. item5 chemical balance 6. item6 refrigerator 7. item7 multimeter ( ph, conductivity etc ) 8. item8 uv vis spectrophotometer 9. item9 digital balance10. item10 stereo microscope 11. item11 mirror stereoscope with 4x binocular 12. item12 rain gauge 13. item13 anemometer 14. item14 fortin barometer 15. item15 secchi disk instruments for 16. item16 8085 microprocessor 17. item17 apparatus to design a circuit to simulate the solution of a 1st / 2nd order differential equation instruments for 18. item18 digital turbidity meter 19. item19 co2 sensor 20. item20 bod shaking incubator 21. item21 thermo class ii, type a2 biological safety cabinet 22. item22 hygrometer 23. item23 paper chromatography set with whatman chromatography paper amino acid set 24. item24 pcr machine ( 96 well ) 25. item25 elisa instrument and kits...

Department of Higher Education - West Bengal

23999887 supply of instruments for the department of zoology at nabadwip vidyasagar college , nabadwip , nadia . 1 do meter 2 digital conductivity meter ( portable ) 3 digital turbidity meter 4 ph meter 5 co2 sensor 6 digital thermometer with long probe 7 multipara meter water quality meter 8 medico centrifuge 9 centrifuge tubes 10 bod shaking incubator 11 gel electrophoresis vertical 12 thin layer chromatography with full set ( tlc ) with kit and accessories. 13 thermo class ii, type a2 biological safety cabinet 14 uv vis spectrophotometer 15 digital photo colorimeter 16 digital autoclave 17 digital flame photometer 18 microscope monocular 19 microscope trinocular 20 microscope with computer attachment and full set computer with software and photographic attachment – camera 21 checker plus pocket ph tester 22 multiparameter pcs tester 35 ( pocket type ) 23 hygrometer 24 lux meter 25 microscope with desktop pc 26 rotary microtome 27 paper chromatography set with whatman chromatography paper an amino acid set 28 pcr machine ( 96 well ) 29 camera 30 camera lens 31 elisa instrument and kits 32 mixer grinder 33 microwave oven...

Department of Higher Education - West Bengal

23693083 supply of laboratory instruments in the department of botany under raiganj university 2 automated thermal cycler ( dual block pcr machine ) : all necessary specifications attach separately in soq. 3 biosafety cabinet ( class ii ) : all necessary specifications attach separately in soq. 4 bacteriological incubator ( approx. 200 litres capacity ) : all necessary specifications attach separately in soq. 5 bod incubator n ( approx. 200 – 250 litres capacity ) n : all necessary specifications attach separately in soq. 6 bench top cooling centrifuge : all necessary specifications attach separately in soq. 7 uv visible spectrophotometer : all necessary specifications attach separately in soq. 8 ultra low deep freezer : all necessary specifications attach separately in soq. 9 double distillation plant minimum 2 litres output per hour : all necessary specifications attach separately in soq. 10 bench top orbital shaking incubator : all necessary specifications attach separately in soq. 11 phase contrast hd inverted binocular microscope : all necessary specifications attach separately in soq. 12 trinocular microscope : all necessary specifications attach separately in soq. 13 semi automated rotary microtome : all necessary specifications attach separately in soq. 14 uv transilluminator : all necessary specifications attach separately in soq. 15 automated thermal cycler ( pcr machine ) : all necessary specifications attach separately in soq. 16 digital ph meter with electrode for water and soil analysis : all necessary specifications attach separately in soq. 17 analytical balances digital ( specificity 0.0001 g ) : all necessary specifications attach separately in soq. 18 vertical gel electrophoresis chamber : all necessary specifications attach separately in soq. 19 horizontal gel electrophoresis chamber : all necessary specifications attach separately in soq. 20 power pack for gel electrophoresis system : all necessary specifications attach separately in soq. 21 probe sonicator : all necessary specifications attach separately in soq. 22 water bath with circulator : all necessary specifications attach separately in soq....

Institute Of Engineering And Technology - West Bengal

23005586 supply , installation , testing and commissioning of lab equipment for the department of food technology 1 softy maker 2 softy maker 3 soxhlet extraction unit with glass parts 4 soxhlet extraction unit with glass parts 5 sausage filler 6 sausage filler 7 tds meter 8 tds meter 9 tray drier 10 tray drier 11 trinocular microscope 12 trinocular microscope 13 ultra sonicator probe type 14 ultra sonicator probe type 15 ultrasound water bath 16 ultrasound water bath 17 vaccum oven with vaccum pump 18 vaccum oven with vaccum pump 19 vaccum packaging machine 20 vaccum packaging machine 21 vortex mixture 22 vortex mixture 23 water activity meter 24 water activity meter 25 weighing balance ( 0.01, 0.001 g accyracy ) 26 weighing balance ( 0.01, 0.001 g accyracy ) 27 meat grinder 28 meat grinder 29 hydraulic press 30 hydraulic press 31 digital display 4 unit heating mantle 32 digital display 4 unit heating mantle 33 sieve shaker 34 sieve shaker 35 automatic titrator 36 automatic titrator 37 bomb calorimeter ( imported ) 38 bomb calorimeter ( imported ) 39 colorimeter 40 colorimeter 41 crown corking machine 42 crown corking machine 43 dessicator 44 dessicator 45 gel electrophorosis unit with power pack whole unit 46 gel electrophorosis unit with power pack whole unit 47 hot plate with stirrer 48 hot plate with stirrer 49 hot plate 50 hot plate 51 grain divider 52 grain divider 53 gauge meter 54 gauge meter 55 magnetic stirrer with hot plate ( controlled heating ) 56 magnetic stirrer with hot plate ( controlled heating ) 57 bod incubator 58 bod incubator 59 refrigerator laboratory centrifuge 60 refrigerator laboratory centrifuge 61 deep freezers 62 deep freezers 63 digital multi thermometer 64 digital multi thermometer 65 falling number apparatus ( imported ) 66 falling number apparatus ( imported ) 67 microscope 68 microscope 69 micro pipette 70 micro pipette 10 100 μl 71 micro pipette 72 micro pipette 100 1000 μl 73 sedimentation shaker with volumetric flask 74 sedimentation shaker with volumetric flask 75 electric mixtuire ( light duty liquid mixture ) 76 electric mixtuire ( light duty liquid mixture ) 77 heat sealing machine 78 heat sealing machine 79 relative humidity chamber 80 relative humidity chamber 81 glass wet and dry bulb thermometer 82 glass wet and dry bulb thermometer 83 fibre estimation system 84 fibre estimation system 85 auto pipette 86 auto pipette 87 electric butter churner 88 electric butter churner 89 baking oven 90 baking oven 91 laboratory pulvarizer ( hammer mill ) 92 laboratory pulvarizer ( hammer mill ) 93 juicer mixture grinder 94 juicer mixture grinder 95 micropipette stand 96 micropipette stand 97 moisture analyzer 98 moisture analyzer 99 mortar and pestle 100 mortar and pestle 101 orifice meter 102 orifice meter 103 paddy dehusker 104 paddy dehusker 105 pasta making machine 106 pasta making machine 107 pipette stand 108 pipette stand 109 potato peeler 110 potato peeler 111 proofing chamber 112 proofing chamber 113 pulper 114 pulper 115 digital abbe refractometer 116 digital abbe refractometer 117 refrigerator double door froast free 118 refrigerator double door froast free 119 rotary evaporator 120 rotary evaporator 121 seed germinator 122 seed germinator 123 shaking incubator 124 shaking incubator 125 shaking water bath 126 shaking water bath 127 hot air oven 128 hot air oven...

Department of Higher Education - West Bengal

21199224 supply of supply of equipments for college 1 cctv requirements: 2 2 5 megapixel turbo hd bullet camera with hd video output, hdtvi technology, ip66 weatherproof, 3 axis adjustment hikvision 1080p resolution. item1 1 nos 3 3 23 x optical zoom 5mp turbo hd dome camera with hd video output, hdtvi technology 3 axis adjustment hikvision 1080p resolution item2 1 nos 4 4 32 channel dvr hikvision 1080p resolution full hd. & sata h 265 video compression hd input, mobile surveillance. hdmi port vga usb port with audio output and input item3 1 nos 5 5 8 tb surveillance sata hard disk item4 1 nos 6 6 installation of camera item5 1 nos 7 7 installation of rack fixing 270 u item6 1 nos 8 8 ups 1100 va, with tubular exide battery item7 1 nos 9 9 c.c. tv. power supply 32 channel item8 1 nos 10 10 video jack item9 1 nos 11 11 power jack item10 1 nos 12 12 40 inch full hd 1080 p resolution led tv sony / samsung item11 1 nos 13 13 pvc box for c.c.tv 4x6 size item12 1 nos 14 14 hdmi 5 mtrs cable support 1080p resolution item13 1 nos 15 15 outdoor pvc pipe item14 1 nos 16 16 3+1 copper wire 90 mtrs item15 1 nos 17 17 weather station nspecifications: seven parameter automatic weather ( met ) stations. nsensors: rainfall : funnel of 400 cm2 : resolution 0.2 or 0.5 mm wind speed : range 0 50 m / s: accuracy ±3%: resolution 0.1 m / wind direction : range 0 360° : accuracy ±3° : resolution 1° n temperature : range 30°c to + 50°c: accuracy ±0.5°c: resolution 0.1°c relative humidity : range 0 100% : accuracy ±3% : resolution 1% n barometric pressure : range 600 1100 hpa : accuracy ±2% : resolution 1 hpa n solar radiation : 0 2000 w / m2 : accuracy ±5% : resolution 1 w / m2 ndata logging: internal data logging with flash memeory card or similar technique ndata transferring: through ( usb ) or wireless and provision of gsm modem npower supply: with battery backup of upto 1 hour attached with each machine nportability: with standard portable 2.5 3 meter tripod mast nwarranty of i year or more for all systems ninstallation and training at our premises free of cost n item16 1 nos 18 18 eppendorf mastercycler ep gradient 96 well pcr thermal cycler [ master cycler 5331 ] item17 1 nos 19 19 waters 2795 hplc system with 2487 uv vis detector or photodiode array detector with c18 column. item18 1 nos 20 20 hplc system column item19 1 nos 21 21 life technologies e gel imager camera hood gel doc system item20 1 nos 22 22 rotatory evaporator item21 1 nos 23 23 thermo fischer scientific bod 10a15 incubator item22 1 nos 24 24 orbital shaking incubator remi item23 1 nos 25 25 advanced compound students microscope nlabomed cxl mono led n item24 1 nos 26 26 led display monitor 16 ( with hdmi socket ) item25 1 nos 27 27 central processing unit ( with steel cabinate, processor : intel 8th generation core i3 8100 ( 6m cache, 3.60 ghz ) nram : 8 gb, ddr4, 2666mhz; up to 32gb nhard disk : 1tb 3.5inch 7200 rpm sata hard drive || graphics : intel uhd graphics 630 with shared graphics memory noperating system : dos ubantu || warranty : 1yr onsite service ) item26 1 nos 28 28 ups 700va , item27 1 nos 29 29 keyboard and mouse usb type ( lenevo ) item28 1 nos 30 30 printer desktop hp laser jet m1136 mpf item29 1 nos 31 31 de humidifier nideal for a large room, with an approximate size of 30m x 60m. nextraction rate of 20 litres for maximum energy efficiency. nair flow of 165cbm per hour with a variance of 10 per vent. nsound emission of less than 50db. nhumidity control of 40 per cent to 80 per cent. n item30 1 nos...

University Of Burdwan - West Bengal

21157548 tender for repair and maintenance of equipments 1. bod incubators 2. laminar air flows 3. hot air ovens 4. shaking incubators 5. incubators 6. autoclaves 7. spectrophotometer 8. colorimeters 9. centrifuge machines 10. hplc 11. spare parts of gc fid (se 30 column: 30 m length x 0.32 mm diam. x 0.25 jim film) 12. bod shaker incubator 13. cooling centrifuge 14. microtomes 15. plant growth chamber 16. 80°.c freezer 17. c02 incubator 18. pcr...

Aliah University - West Bengal

20832691 supply and installation of laboratory instruments and equipments for undergraduate and postgraduate laboratories 1.001 refrigerated centrifuge 1.002 refrigerated centrifuge, with rotor 1.003 minus 86°c ultra low temperature upright freezer 1.004 co2 incubator 1.005 spectrophotometer 1.006 micropipette ( 0.5μl – 10 μl ) 1.007 micropipette ( 10 μl – 100 μl ) 1.008 micropipette ( 100 μl – 1000 μl ) 1.009 real time pcr system ( 96 well, 0.2 ml block ) 1.01 double beam uv visible spectrophotometer 1.011 inverted research microscope for bright field, phase contrast, fluorescence & plasdic application along with high resolution color microscopy camera and computer & software image analysis 1.012 refrigerated bench top centrifuge 1.013 table top micro centrifuge 1.014 orbital shaking incubator ( 215 lit ) 1.015 b.o.d. incubator shaker 1.016 water bath 1.017 isoelectric focusing system 1.018 large format vertical electrophoresis cell for 16 x16 cm gels 1.019 horizontal gel electrophoresis ( mini size; gel size 7.8x10cm ) 1.02 horizontal gel electrophoresis ( midi size; gel size 13x13cm, 7.8x10cm, 4.8x7.5cm ) 1.021 uv transilluminator ( high / low intensity, 312 nm, 15x15 cm filter, 6x8 watt tubes, 10000 μw / cm2 intensity ) 1.022 ice flakers ...

Department of Higher Education - West Bengal

19931922 supply of dept of microbiology items : i uini vertical gel ( 10x 8 cm gels ) with power supply basic 2 gradient nhermal cycler 3 refrigerated circulating water bath 4 orbital shaking incubator with voltage stabiliser 5 bio safety cabinet class ii, type a2 6 anaerobic culture jar 7 liquid nitrogen container 8 deuterium lamp and tungsten filament lamp for jasco v630 9 uulti parameter meter , 10 hot pate / water heater ( x2 ) 11 4 degree refrigerator , 12 finnipipette f2 kits 2 ( 0.2 to 1000 l ) ...

Department of Higher Education - West Bengal

19544228 procurement of various equipments microprocessor based bench top 2.43 conductivity/tds/sali temp. meter led light. see digital turbidity meter. see nit doc for detailed 2.44 specification. orbital shaking incubator. see nit doc for detailed 2.45 specification. water bath with shaker. see nit doc for detailed 2.46 specification. magnetic stirrer hot plate with beads. see nit 2.47 doc for detailed specification. vaccum pump. see nit doc for detailed specification. 248 gps system with software. see nit doc for detailed 2.49 specification. environmental chamber with microprocessor 2.5 based photo period & huuidity, air flow and light steripipette xl. see nit doc for detailed specification. 2.51 digital hot alr oven. see nit doc for detailed 2.52 specification. 12 channel micro pipette. see nit doc for detailed 2s53 specification. 8 channel micro pipette. see nit dcc for detailed 2.54i rfid based library automation system full setup(tag. 2 s5 station reader, theft detector, smartcard) with koha integrated software, reader ror tagging and circulation ....

Aliah University - West Bengal

18825491 e tender for supply and installation of laboratory instruments and equipments for undergraduate and postgraduate laboratories of dept. of biological sciences, aliah university, au / reg / enit 053 / 2018 19 1.001 refrigerated centrifuge 1.002 refrigerated centrifuge, with rotor 1.003 minus 86°c ultra low temperature upright freezer 1.004 co2 incubator 1.005 spectrophotometer 1.006 micropipette ( 0.5μl – 10 μl ) 1.007 micropipette ( 10 μl – 100 μl ) 1.008 micropipette ( 100 μl – 1000 μl ) 1.009 real time pcr system ( 96 well, 0.2 ml block ) 1.01 thermal cycler ( 96 well, 0.2 ml ) 1.011 double beam uv visible spectrophotometer 1.012 inverted research microscope for bright field, phase contrast, fluorescence & plasdic application along with high resolution color microscopy camera and computer & software image analysis 1.013 refrigerated bench top centrifuge 1.014 table top micro centrifuge 1.015 orbital shaking incubator ( 215 lit ) 1.016 b.o.d. incubator shaker 1.017 digital bod incubator 1.018 hot air oven 1.019 water bath 1.02 isoelectric focusing system 1.021 large format vertical electrophoresis cell for 16 x16 cm gels 1.022 gel doc system with high resolution, cooled camera and application controlled softwares for fluorescence and chemiluminescence applications 1.023 power pack ( power supply, constant voltage, current, led display, 27x26x12cm, 5 300v, 1 300ma, max 90w, 2 output pack ) 1.024 semi dry trans blot system with standard accessories 1.025 western blotting unit ( trans blot system with standard accessories, gel size 10x10 cm ) 1.026 horizontal gel electrophoresis ( mini size; gel size 7.8x10cm ) 1.027 horizontal gel electrophoresis ( midi size; gel size 13x13cm, 7.8x10cm, 4.8x7.5cm ) 1.028 double vertical gel electrophoresis unit ( gel size 8.2x8.5cm ) 1.029 uv transilluminator ( high / low intensity, 312 nm, 15x15 cm filter, 6x8 watt tubes, 10000 μw / cm2 intensity ) 1.03 ice flakers ...

Department Of Higher Education And Training - West Bengal

18092247 tender for purchase of laboratory equipments apparatus 20 kymograph with with all accessories (dia ), aarson scientific works aarson scientific works ,ambala cantt, ambala, haryana/zoology : 32 topographical map 73 m/2 /geography 33 topographical map 73 m/2/geography 34 gps/geography35 transit theodolite/geography 36 planimeter/geography 37 satelite image/geography38 weather map/geography 39 pen based fluoride meter brand extech model fl700/geography 40 soil kit box/geography41 rock and mineral/geography 42 white board 6ft x 4 ft/office 43 uv vis spectrophotometer perkin elmer (lambda 365, double beam uv/vis spectrophotometer)/chemistryi perkin diner (spectrun two srten. 100 240v. 5060hz standard dtc. kbr. sp1o)chcmistr 44 digital melting point apparanmi veego (model: ds).cbe.rn’t 45 digital balance (up 104 decimal pomli) mettler toledo (model: me2oe ‘ag i. 12v 0.s4a )tchenñtrv’ 46centrifuge machine remi 6x15 ml capacity laboratory centrifuge 854/6/chemistry digital colorimeter systronics (model: 115)/chemistry potentiometer systronics (model: 318)/chemistrymicrowave oven samsung (model: ce73jd b/xtl, black, 21 l capacity, 800 watt)/chemistry heating mantle ajanta/chemistry magnetic stirrer remi 2 ltr stirrers with hotplate 2 mlh/chemistryvacuum pump ssu value vacuum pump capacity of 50 liters/min/chemistry item53 digital calorimeter parr instrument company (6755 solution calorimeter)/chemistry item54 digital ph meter systronics (model: 802)/chemistry item55uv chamber ultra violet (uv) cabinet : u v cabinet made by m.s sheet paints complete with one short wave and one long wave and one fluorescent tube of 12” length with gadget easily operated front door and viewer at top protected with glass plate/chemistry remi orbital shaking incubator remi cis 24 plus: 50 600 c , 215 l...

University Of Burdwan - West Bengal

18058601 tender for repair & maintenance of equipments: . bod incubators, hot air ovens, shaking incubator, incubator, autoclave, servicing of thermo make water jacketed co2 incubator model no 4111...

Bidhan Chandra Krishi Viswavidyalaya - West Bengal

17429477 supply of 1. mono quartz water distillation unit 2. digital top loading electronic balance 3. digital top loading electronic balance 4 orbital shaking incubator 5. discharge measuring device...

Bidhan Chandra Krishi Viswavidyalaya - West Bengal

17393418 tender for “management of groundwater irrigation 1. mono quartz water distillation unit 2. digital top loading electronic balance 3. digital top loading electronic balance 4. orbital shaking incubator 5. water discharge measuring device...

Food Safety And Standards Authority Of India - West Bengal

16606005 request for proposal by food safety and standards authority of india for setting up of microbiology section and installation of equipments in central food laboratory bio safety cabinet, autoclave, laboratory refrigerator 2oc – 8oc, digital balance, circulating water bath, incubator (multi chambered), hot air oven, fogger, automatic colony counter (bench top, digital), anaerobic work station, ultra pure water purification system, fully automated elisa reader & washer, temperature data logger, trinocular microscope with digital display system, automatic safety bunsen burner, shaking incubator (orbital), vacuum filtration assembly, lender/homogenizer, air sampler, laboratory glassware washer/dryer, automated enumeration system, automated pathogen detection and identification system, mcbs and mcb distribution boards,heating, ventilation and air conditioning (hvac) system etc....

University Of Burdwan - West Bengal

16461701 tender for repairing & maintenances and supply of items 1. bod incubators 2. hot air ovens 3. shaking incubator 4. incubator 5. autoclave 6. servicing of lab x incubator shaker...

University Of Burdwan - West Bengal

13507764 tender for repair & maintenance of equipments 1. bod incubators 2. hot air ovens 3. shaking incubator 4. incubator 5. autoclave 6. spectrophotometer 7. colorimeter 8. centrifuge machine 9. spare parts of gc fid ( se 30 column: 30 m length × 0.32 mm diam. × 0.25 μm film )...