South Eastern Railways - West Bengal

33850288 supply of m 48 kit for air dryer of trident make to model no. ld 2000120 consisting of 14 items. 1) filter element (trident part no.ad433) =01 no. 2) cup top filter (trident part no.cd668)=01 no. 3) cup bottom filter (trident part no.cd669)= 01 no. 4)spare kit filter bottom (trident part no.as443)=01 no. 5) spare kit valve double poppet (trident part no.as444)=01 no. 6) filter element m250y (trident part no.ac077)=01 no. 7) spare kit valve shuttle (trident part no.as445)=01 no. 8)spare kit for purge valve (trident part no.as446)=01 no. 9)bag cartridge desiccant ( trident part no.cd671)=02 nos. 10) spring compactor (trident part no.cd673=02 nos. 11) spare kit seals tower (trident part no.as447)=01 no. 12) sub assly humidity indicator 3 r 1 (trident part no.ad925)=02 nos.13)gasket pad amisco solenoid valve (trident part no.as079a)=02 nos. 14) spare kit seals controller box ( trident part no.as709)=01 nom 48 kit for air dryer of trident make to model no. ld 2000120 consisting of 14 items. 1) filter element (trident part no.ad433) =01 no. 2) cup top filter (trident part no.cd668)=01 no. 3) cup bottom filter (trident part no.cd669)= 01 no. 4)spare kit filter bottom (trident part no.as443)=01 no. 5) spare kit valve double poppet (trident part no.as444)=01 no. 6) filter element m250y (trident part no.ac077)=01 no. 7) spare kit valve shuttle (trident part no.as445)=01 no. 8)spare kit for purge valve (trident part no.as446)=01 no. 9)bag cartridge desiccant ( trident part no.cd671)=02 nos. 10) spring compactor (trident part no.cd673=02 nos. 11) spare kit seals tower (trident part no.as447)=01 no. 12) sub assly humidity indicator 3 r 1 (trident part no.ad925)=02 nos.13)gasket pad amisco solenoid valve (trident part no.as079a)=02 nos. 14) spare kit seals controller box ( trident part no.as709)=01 no,m 48 kit for air dryer of trident make to model no. ld 2000120 consisting of 14 items. 1) filter element (trident part no.ad433) =01 no. 2) cup top filter (trident part no.cd668)=01 no. 3) cup bottom filter (trident part no.cd669)= 01 no. 4)spare kit filter bottom (trident part no.as443)=01 no. 5) spare kit valve double poppet (trident part no.as444)=01 no. 6) filter element m250y (trident part no.ac077)=01 no. 7) spare kit valve shuttle (trident part no.as445)=01 no. 8)spare kit for purge valve (trident part no.as446)=01 no. 9)bag cartridge desiccant ( trident part no.cd671)=02 nos. 10) spring compactor (trident part no.cd673=02 nos. 11) spare kit seals tower (trident part no.as447)=01 no. 12) sub assly humidity indicator 3 r 1 (trident part no.ad925)=02 nos.13)gasket pad amisco solenoid valve (trident part no.as079a)=02 nos. 14) spare kit seals controller box ( trident part no.as709)=01 no page 1 of 5 run date/time: 08/09/2022 08:51:28stores pcmm/south eastern rly tender document...

Northeast Frontier Railway - West Bengal

33370245 supply of air dryer maintenance kitair dryer maintenance kit,air dryer maintenance kit consisting of 17 items(qty in per kit)>1)kit for precoalescer ftil pt no790029165=1no,2)kit for regenerating orifice ftil pt no790029111=1no,3)kit for final filter ftil pt no790029125=1no,4)kit for desiccant canister ftil pt no790029195 =2nos,5)kit for humidity indicator ftil pt no790029105=2nos,6)kit for inlet check valve ftil pt no790029135=2nos,7)kit for drain valve ftil pt no790029175=1no,8)kit for outlet check valve ftil pt no790029145=2nos,9)kit for purge valve ftil pt no790029185=2nos,10)kit for solenoid valve ftil pt no790029155=2nos, as per drg.no. 11)kit fordesiccant compactor ftil pt no 790029205= 2nos.. 12) flange and purge valve o rings as per ftil pt. no. 029719000, qty 08 nos. 13) dryer body and spacer gasket/seats as per ftil pt. no. 029715000, qty 04 nos. 14) gasket for inlet manifold body as per ftil pt. no. 029718000, qty 01 nos. 15) seal for outlet manifold body as per ftil pt. no. 029713000, qty 02 nos. 16) gasket for electrical box as per ftil pt. no. 029712000, qty 01 nos. 17) gasket for drain valve as per ftil pt. no. 029720000, qty 01 nos....

Northeast Frontier Railway - West Bengal

33129029 supply of air dryer maintenance kit consisting of 17 items(qty in per kit)>1)kit for precoalescer ftil pt no790029165=1no,2)kit for regenerating orifice ftil pt no790029111=1no,3)kit for final filter ftil pt no790029125=1no,4)kit for desiccant canister ftil pt no790029195 =2nos,5)kit for humidity indicator ftil pt no790029105=2nos,6)kit for inlet check valve ftil pt no790029135=2nos,7)kit for drain valve ftil pt no790029175=1no,8)kit for outlet check valve ftil pt no790029145=2nos,9)kit for purge valve ftil pt no790029185=2nos,10)kit for solenoid valve ftil pt no790029155=2nos, as per drg.no. 11)kit fordesiccant compactor ftil pt no 790029205air dryer maintenance kit consisting of 17 items(qty in per kit)>1)kit for precoalescer ftil pt no790029165=1no,2)kit for regenerating orifice ftil pt no790029111=1no,3)kit for final filter ftil pt no790029125=1no,4)kit for desiccant canister ftil pt no790029195 =2nos,5)kit for humidity indicator ftil pt no790029105=2nos,6)kit for inlet check valve ftil pt no790029135=2nos,7)kit for drain valve ftil pt no790029175=1no,8)kit for outlet check valve ftil pt no790029145=2nos,9)kit for purge valve ftil pt no790029185=2nos,10)kit for solenoid valve ftil pt no790029155=2nos, as per drg.no. 11)kit fordesiccant compactor ftil pt no 790029205,air dryer maintenance kit consisting of 17 items(qty in per kit)>1)kit for precoalescer ftil pt no790029165=1no,2)kit for regenerating orifice ftil pt no790029111=1no,3)kit for final filter ftil pt no790029125=1no,4)kit for desiccant canister ftil pt no790029195 =2nos,5)kit for humidity indicator ftil pt no790029105=2nos,6)kit for inlet check valve ftil pt no790029135=2nos,7)kit for drain valve ftil pt no790029175=1no,8)kit for outlet check valve ftil pt no790029145=2nos,9)kit for purge valve ftil pt no790029185=2nos,10)kit for solenoid valve ftil pt no790029155=2nos, as per drg.no. 11)kit fordesiccant compactor ftil pt no 790029205 => limited...

Northeast Frontier Railway - West Bengal

33031299 supply of kit for desiccant compactor for gm loco for faively make air dryer as per faiveley part no. 790029205.kit for desiccant compactor for gm loco for faively make air dryer as per faiveley part no. 790029205.,kit for desiccant compactor for gm loco for faively make air dryer as per faiveley part no. 790029205. => limited...

Indian Army - West Bengal

32298994 procurement of medical stores sodium ( na+ ) , potassium ( k+ ) , hba1c reagent , calibrator kit 31 , %a1c performance verifier i , %a1c performance verifier ii , isoenzyme performance verifier i , isoenzyme performance verifier ii , liquid performance verifier i , liquid performance verifier ii , fs reconstitution diluent , fs diluent pack 2 ( bsa / saline ) , fs diluent pack 3 ( specialty diluent / water ) , fs micro tip , fs cuvettes , micro samples cups ( 0.5ml ) , versa tip , desiccant pack , reference fluid 800 , microsensor check fluids i & ii , air filter...

Indian Army - West Bengal

32153538 procurment of medical stores procurment of medical stores , drugs , total bilirubin (tbil) , bilirubin, unconjugated and conjugated (bubc) , total protein (tp) , cholesterol (chol) slides , direct hdl cholesterol (dhdl) , calibrator kit 25 dhdl , blood urea nitrogen (bun/urea) , creatinine idms (crea idms) , calibrator kit 1 bun/urea, ca, crea, glu, lac, li, mg, phos, sali, theo, uric , calibrator kit 2 chol, cl , eco2, k+, na+, trig , calibrator kit 4 alb, bubc, fe, tbil, tibc, tp , uric acid (uric) , calibrator kit 6 che, ckmb , triglyceride (trig) , alkaline phosphatase (alkp) , glucose (glu) , albumin (alb) , aspartate aminotransferase (ast) , alanine aminotransferase (altv) , calibrator kit 3 acp, alt, alkp, amyl, ast, ck, ggt, ldh, lipa , isoenzyme performance verifier i , isoenzyme performance verifier ii , liquid performance verifier i , liquid performance verifier ii , fs micro tip , micro samples cups (0.5ml) , versa tip , potassium (k+) , sodium (na+) , hba1c reagent , calibrator kit 31 , %a1c performance verifier i , %a1c performance verifier ii , fs humidification pack , desiccant pack...

Indian Institute Of Science Education And Research - West Bengal

31900937 purchase and installation of sparesspares detector with dtgs alpha ii and desiccant rechargeble , detector with dtgs alpha ii for details specification see the annexure vi of the tender notice , desiccant, rechargeble, user replaceble for details specification see the annexure vi of the tender notice => limited...

Indian Institute Of Science Education And Research - West Bengal

31611263 spares detector with dtgs alpha ii and desiccant rechargeble , detector with dtgs alpha ii for details specification see the annexure vi of the tender notice , desiccant,rechargeble, user replaceble for details specification see the annexure vi of the tender notice => limited...

Northeast Frontier Railway - West Bengal

31065094 supply of precoalescer ftil pt no790029165=1no,2)kit for regenerating orifice ftil pt no790029111=1no,3)kit for final filter ftil pt no790029125=1no,4)kit for desiccant canister ftil pt no790029195 =2nos,5)kit for humidity indicator ftil pt no790029105=2nos,6)kit for inlet check valve ftil pt no790029135=2nos,7)kit for drain valve ftil pt no790029175=1no,8)kit for outlet check valve ftil pt no790029145=2nos,9)kit for purge valve ftil pt no790029185=2nos,10)kit for solenoid valve ftil pt no790029155=2nosprecoalescer ftil pt no790029165=1no,2)kit for regenerating orifice ftil pt no790029111=1no,3)kit for final filter ftil pt no790029125=1no,4)kit for desiccant canister ftil pt no790029195 =2nos,5)kit for humidity indicator ftil pt no790029105=2nos,6)kit for inlet check valve ftil pt no790029135=2nos,7)kit for drain valve ftil pt no790029175=1no,8)kit for outlet check valve ftil pt no790029145=2nos,9)kit for purge valve ftil pt no790029185=2nos,10)kit for solenoid valve ftil pt no790029155=2nos,air dryer maintenance kit consisting of 17 items(qty in per kit)>1)kit for precoalescer ftil pt no790029165=1no,2)kit for regenerating orifice ftil pt no790029111=1no,3)kit for final filter ftil pt no790029125=1no,4)kit for desiccant canister ftil pt no790029195 =2nos,5)kit for humidity indicator ftil pt no790029105=2nos,6)kit for inlet check valve ftil pt no790029135=2nos,7)kit for drain valve ftil pt no790029175=1no,8)kit for outlet check valve ftil pt no790029145=2nos,9)kit for purge valve ftil pt no790029185=2nos,10)kit for solenoid valve ftil pt no790029155=2nos, as per drg.no. 11)kit fordesiccant compactor ftil pt no 790029205...

Indian Army - West Bengal

30670503 bids are invited for nipple grease button head 9mm long , nipple grease conical head angled 1 obliuqe 8 sp , solution valcanising tube 01 tube of 75 , plywood for general purposes bwr ab 5 pl , broom country , cotton waste coloured , abrasives cloth emery orcorundum size 0 , solvent rust , polish wax , sodaash tech , desiccant silica gel , soap laundry , tapeadhesive transparent waterproof widboq title general store exp itemsoem total quantity : 3969...

South Eastern Railways - West Bengal

29783523 supply of m12 kit for air dryer of trident make to model no.ld2000120 consisting of 6 items. 1 ) filter element trident part no.ad433 = 01 no. 2 ) cup top filter trident part no.cd668 = 01 no. 3 ) cup bottom filter trident part no. cd669 = 01 no. 4 ) spare kit filter bottom trident part no. as 443 =01 no. 5 ) spare kit%a0valve double poppet trident part no.as 444 =01 no. 6 ) filter element m250y trident part no.ac077 =01 nom 48 kit for air dryer of trident make to model no. ld 2000120 consisting of 14 items. 1 ) filter element trident part no.ad433 =01 no. 2 ) cup top filter trident part no.cd668=01 no. 3 ) cup bottom filter trident part no.cd669= 01 no. 4 ) spare kit filter bottom trident part no.as443=01 no. 5 ) spare kit valve double poppet trident part no.as444=01 no. 6 ) filter element m250y trident part no.ac077=01 no. 7 ) spare kit valve shuttle trident part no.as445=01 no. 8 ) spare kit for purge valve trident part no.as446=01 no. 9 ) bag cartridge desiccant trident part no.cd671=02 nos. 10 ) spring compactor trident part no.cd673=02 nos. 11 ) spare kit seals tower trident part no.as447=01 no. 12 ) sub assly humidity indicator 3 r 1 trident part no.ad925=02 nos.13 ) gasket pad amisco solenoid valve trident part no.as079a=02 nos. 14 ) spare kit seals controller box trident part no.as709=01 nom12 kit for air dryer of trident make to model no.ld2000120 consisting of 6 items. 1 ) filter element trident part no.ad433 = 01 no. 2 ) cup top filter trident part no.cd668 = 01 no. 3 ) cup bottom filter trident part no. cd669 = 01 no. 4 ) spare kit filter bottom trident part no. as 443 =01 no. 5 ) spare kit%a0valve double poppet trident part no.as 444 =01 no. 6 ) filter element m250y trident part no.ac077 =01 no m 48 kit for air dryer of trident make to model no. ld 2000120 consisting of 14 items. 1 ) filter element trident part no.ad433 =01 no. 2 ) cup top filter trident part no.cd668=01 no. 3 ) cup bottom filter trident part no.cd669= 01 no. 4 ) spare kit filter bottom trident part no.as443=01 no. 5 ) spare kit valve double poppet trident part no.as444=01 no. 6 ) filter element m250y trident part no.ac077=01 no. 7 ) spare kit valve shuttle trident part no.as445=01 no. 8 ) spare kit for purge valve trident part no.as446=01 no. 9 ) bag cartridge desiccant trident part no.cd671=02 nos. 10 ) spring compactor trident part no.cd673=02 nos. 11 ) spare kit seals tower trident part no.as447=01 no. 12 ) sub assly humidity indicator 3 r 1 trident part no.ad925=02 nos.13 ) gasket pad amisco solenoid valve trident part no.as079a=02 nos. 14 ) spare kit seals controller box trident part no.as709=01 no, m 48 kit for air dryer of trident make to model no. ld 2000120 consisting of 14 items. 1 ) filter element trident part no.ad433 =01 no. 2 ) cup top filter trident part no.cd668=01 no. 3 ) cup bottom filter trident part no.cd669= 01 no. 4 ) spare kit filter bottom trident part no.as443=01 no. 5 ) spare kit valve double poppet trident part no.as444=01 no. 6 ) filter element m250y trident part no.ac077=01 no. 7 ) spare kit valve shuttle trident part no.as445=01 no. 8 ) spare kit for purge valve trident part no.as446=01 no. 9 ) bag cartridge desiccant trident part no.cd671=02 nos. 10 ) spring compactor trident part no.cd673=02 nos. 11 ) spare kit seals tower trident part no.as447=01 no. 12 ) sub assly humidity indicator 3 r 1 trident part no.ad925=02 nos.13 ) gasket pad amisco solenoid valve trident part no.as079a=02 nos. 14 ) spare kit seals controller box trident part no.as709=01 no amm / dls / kgp diesel west bengal 3.00 set loco shed stores , ser ccode 005141 odisha 2.00 set smm / els / rou electric odisha 11.00 set loco shed stores depot , ser , m12 kit for air dryer of trident make to model no.ld2000120 consisting of 6 items. 1 ) filter element trident part no.ad433 = 01 no. 2 ) cup top filter trident part no.cd668 = 01 no. 3 ) cup bottom filter trident part no. cd669 = 01 no. 4 ) spare kit filter bottom trident part no. as 443 =01 no. 5 ) spare kit%a0valve double poppet trident part no.as 444 =01 no. 6 ) filter element m250y trident part no.ac077 =01 no amm / dls / kgp diesel west bengal 6.00 set loco shed stores , ser ccode 005141 odisha 7.00 set smm / els / rou electric odisha 11.00 set loco shed stores depot , ser...

Health And Family Welfare Department - West Bengal

29723852 e tender for empanelment of nabl laboratory for testing of drugs, kit, chemicals and reagents and consumables for two years from the date of a.o.c. ( 2021 2023 ) by the deputy director of health services ( e s ) , central medical stores. , barium chloride powder , barium sulphate powder ( 175gm ) , basic fuchsin , benedict solution , bile esculin disc , bile salt , bivalent antigen detecting rapid diagnostic tests ( rdts ) for p. falciparum and p. vivax malaria undr nvbdcp technical specifications: a. description of the test kit: the bivalent rapid diagnostic test ( rdt ) for malaria should comprise of test card ( cassette ) and reagents including buffer solution in a dropping bottle. the test kit should be able to rapidly diagnose both p. falciparum and p. vivax. the test should be based on the principle of capture of parasite antigen from blood using monoclonal antibodies specific for antigen targets. each test kit should contain all the materials required for performing the test including individually packed sterile lancets for pricking, heparinised capillary tubes ( diameter 1mm ) with relevant markings and reaction tubes with stand / wells as required. the manufacturer should have specified international organisation for standardization ( iso ) certification. one should be able to perform the test with the blood taken by finger prick of the patient. temperature stability data: information on thermal stability data for the lab product should be available. type of rdt the rdt should be able to detect p. falcciparaum histidine –rich protein – 2 ( hrp2 ) and p. vivax lactate dehyydrogenase ( pldh ) and not aldolase. rdtperformance criteria : the products should conform to the following set of criteria ( a d ) , based on the results of the evaluation of the who malaria rdt product testing. a. for the detection of plasmodium falciparum ( pf ) in all transmission settings the panel detection score ( pds ) against pf samples should be at least 75% at 200 parasites / ul. b. for the detection of plasmodium vivax ( pv ) in all transmission settings the panel detection score ( pds ) against pv samples should be at least 75% at 200 parasites / ul. c. the false positive rate should be less than 10% . d. the invalid rate should be less than 5%. each lot of rdt should be tested at a designed lot testing laboratory by using who protocol at the time of delivery. only those lots with pass report will be accepted for delivery. content of kit and packaging: each kit should be hermetically sealed in non permeable pouch and should have moisture absorbent material. 10 such test cards ( cassette ) , or lesser quantity as required by the programme should be packed in a box containing the reagents and the test plates. adequate literature detailing the test kit components, principle , methodologies and validity criteria as specified under ‘rdt performance criteria’ should be provided in the kit inserts with the test kits. storage conditions, expiry dates and limitations of test should be provided. the small box should be packed in bigger cardboard carton containing 5 such small boxes. the carton should be sealed with a sealing tape. c. shelf life : shelf life from manufacturing date to expiry date should be at least 2 years and the rdts should not have lost more than 1 / 6th of their effective life from the date at the time the material is offered for inspection .losses due to premature deterioration as a result of biological and other activities during the life of potency of the rapid diagnostic tests will be made good by the firm at its own cost. d. stability requirements at temperatures of intended storage, transport and use : rdts should have high thermal stability for use in areas with very high ambient temperatures as per the evaluation by who malaria rdt product testing against a single cultured p. falciparum isolate at 200 parasites / ul at based line and after 60 days of incubation at room temperature, 35°c and 45° c. e. quality assurance : the product should comply with iso 13485. f. marking / labelling: i. each card ( cassette ) should have space for recording particulars of patients, time and date of the test. ii. the large carton ( containing 10 small boxes ) and small box ( containing 10 tests ) should have the following markings: a. name of the test b. lot number c. manufacturing and expiry date d. name of the manufacturer with address e. details of the contents f. storage conditions. g. handling procedures h. disposal instruction for the box and its contents i. goi, nvbdcp supply –not for sale g. details regarding approval of license: i. manufacturing and marketing license for manufacturing of rapid malaria diagnostic tests should have been obtained from the concerned regulatory authority in the country by the manufacturer. ii. the bidders must submit scientific study report in support of their claim of performance criteria of the offered product, i.e. who findreport mentioning the panel detection score, false positivity rate, invalid rate, ease of use , thermal stability data etc. claim should be supported by reports of actual shelf life studies. iii. reports of proven performance of the offered product in conditions similar to indian field conditions ( room temperature up to 40° c ) with certification of no adverse report for the offered product from the end users during the last five years must be submitted with the bid. iv. the bidders must submit a sample of their product ( for example as two kits to procurement agent for assessment of user friendliness by the procurement agent. v. recommended conditions for storage ( e.g. room temperature ) and shelf life should clearly be mentioned on the label of rdt. h. shipping from manufacturer : before shipping : the manufacturer should provide to the consignees the details of airway bill numbers, airline carrier, flight number, numbers of containers, expectedarrival tiem . these details should be sent by email and flowed up by fax. the shipper ( air carrier ) should be notified of temperature storage requirements by the manufacturer in writing and by clear markings on cartons and related documents. ( stowage of the shipment closeto the skin of some aircraft may result in freezing. ) the manufacturer should initiate shipment only when the consignee has confirmed the receipt of shipping notification. manufacturer should ensure / arrange to have customs agents or other personnel on site to receive materials. shipments should be moved immediately to moderate temperature storage places ( less than 30° c ) .leaving materials on airport tarmacs, in customs sheds , or in vehicles should be avoided. i. ground transportation : ground transportation should be carried out during any stage of delivery without delay, maintaining temperature requirements while the vehicle is moving and is parked. avoid leaving rdts in vehicles parked in the sun. , bleaching powder is1065 / 1989 [ containing not less than 30% w / w of available chlorine & stability ( max. ) = 1 / 15 ] , boric acid ip. , bovine albumin i.p. ( 10 ml vial ) , brain heart infusion agar , brain heart infusion broth , calcium reagent test kit , canada balsam , cea elisa kit , cedarwoodoil 25 gms. , cedarwood oil 30 ml , cefaclor antibiotic disc , cefadroxyl antibiotic disc , cefazolin antibiotic disc , cefdinir antibiotic disc , cefepime antibiotic disc , cefixime antibiotic disc , cefoperazone antibiotic disc , cefoperazone / salbactam antibiotic disc , cefotaxime antibiotic disc , cefpirome antibiotic disc , cefpodoxime antibiotic disc , cefprozil antibiotic disc , ceftazidime antibiotic disc , ceftizoxime antibiotic disc , ceftriaxone / salbactum antibiotic disc , ceftriaxone antibiotic disc , cefuroxime antibiotic disc , cefuroxime sodium antibiotic disc , cephalexin antibiotic disc , cephaloridine antibiotic disc , cephalothin antibiotic disc , chloramphenicol antibiotic disc , chlorhexidine gluconate 4% w / v for surgical scrubbing , chloroform a.g. , chlorohexidine gluconate3% ( w / v ) and strong cetrimide 6%solution , cholesterol test kit , ciprofloxacin antibiotic disc , citric acid , citrosteril disinfectant chemical lotion , clarithromycin antibiotic disc , clindamycin antibiotic disc , cloxacillin antibiotic disc , collodian , conc. hydrochloric acid , conc. sulphuric acid , coombs diluents ( gel system ) , cord blood processing kit ( cbp kit ) for the cord blood bank 1. the cbp kit must consist of three bags integrally connected by tubing, two of which are pvc bags one larger bag & one smaller bag and a third smallest bag which is the cryo bag / freezing bag. 2. the larger bag should have a fill volume of 200ml with an attached spike for transferring content from a different collection bag. it must have one leak proof access port for injecting chemicals inside or taking out sample. one additional entry port to this bag is preferred for injecting chemicals only through the nozzle of the syringe without using needle with very narrow calibre connecting tubing for administration of cryoprotectant ( s ) . 3. other smaller bag should have a fill volume of 150ml. it must have one leak proof access port for injecting chemicals inside or taking samples from the bag. 4. the third integrally attached bag ( cryo bag / freezing bag ) consists of eva material or approved material for storing stem cells at ultra low temperature ( minus 196°c ) of liquid nitrogen. it must be a 3d bag ( 3 dimensional ) with two compartments of 20ml & 5ml capacity with intercommunication. 5. length of this cryo bag / freezing bag is 85 87mm & width 63 65mm ( however the total width is 71 73mm including the height of the two ports ( for connecting spike for transplant ) of the bag one connected with the 20ml part and other connected with the 5ml part. this cryo bag / freezing bag along with at least 90mm integral tube segment should fit inside the metal cassette with dimension 91 92mm ( length ) x 84 85mm ( width ) x 8 9mm ( thickness ) for preservation. 6. temperature range of storage should be minus 196°c plus 40°c. 7. easily manipulative clamp must be present on every connecting tubing from bag to bag and from bag to spike and bag to entry or exit ports. 8. the kit should have an expiry of at least 2 years from the date of manufacture. 9. the kit manufacturing process should follow the national and or international standards like iso etc. so that the bags are pyrogen free, sterilised, animal pathogenicity test passed, can withstand the shearing force during centrifugation etc. 10. should provide copy of the supply order to other national or international cord blood banks. 11. should provide customer satisfaction certificate for the product. 12. specimen of the kit must be provided to the tender committee for precise verification of the size, shape, measurement and other specifications. 13. other requirement ( if approved and order is placed for purchase ) : each supply lot / batch has to be provided with certificate of analysis ( quality assurance certificate ) otherwise the kit will not be accepted. 14. should have icmed 13485 certification by qci or is / iso 13485 certification or ce certificate or us fda approval certificate. , co trimoxazole antibiotic disc , cpk ( mb ) test kit , cpk test kit , c reactive protein ( immunoterbedimetric ) test kit , creatinine test kit , cresol with soap solution 50% i.p. , de ionized water , dengue detection kit ( igg antibody ) elisa , dengue igm capture elisa kit technical specification: 1 ) the elisa kit should be designed for qualitative detection of dengue igm antibodies of all 4 dengue serotypes in human serum. 2 ) the kit should be provided with the following materials and reagents: a. anti human igm coatedbreak apart microwells ( 12*8=96 wells ) . desiccant should be provided for storing the unused microwells which are to be resealed immediately. b. horseradish peroxidase conjugated monoclonal antibody tracer with preservatives. c. chromogenic substrate in buffer. d. positive control in the form of positive human serum with preservatives and antibiotics. e. negative control in the form of confirmed negative human serum with preservatives and antibiotics. f. calibrators. g. sample diluents. h. wash buffer. i. stop solution. 3 ) the time required for performing the test for detection of dengue igm, should range between 2 4 hours. 4 ) the elisa kit for detection of dengue igm should have a sensitivity of >95% and a specificity of >98%. 5 ) the kit should be such that, one well is to be consumed for evaluation of each sample ( barring the wells used for control ) . 6 ) test elisa kit should distinguish between dengue and other diseases with similar clinical presentation. 7 ) the kit should have a shelf life of at least one year when stored at an ambient temperature of 2ºc 8ºc. 8 ) transportation should be under cold chain 9 ) test kit should fit in all the commonly available brand / make of elisa reader & washer machine. 10 ) the volume of each and every reagents or consumables supplied in a pack ( for 96 wells ) should be such that, tests can be run at least in twelve occasions by using the 96 wells. 11 ) user certificates from the reputed institution. , dengue ns1 antigen detection kit ( elisa ) , developer ( x ray film ) , disinfectant fluids ( black ) , phenolic type, grade 3 ( rw coeff 5 7 ) is 1061:1997 , doxycyclin antibiotic disc , drabkin’s solution , durham’s tube , e.d.t.a. powder , esbachs reagent , estradiol elisa kit , ethanol 95% v / v ( rectified spirit ) 100 ml , ethanol 95% v / v ( rectified spirit ) , ether solvent , ferritin elisa , fixer ( x ray film ) , formaldehyde tablet , formalin solution 40% , fpsa elisa , french chalk , fsh elisa , ft3 elisa , ft4 elisa , furazolidone antibiotic disc , gamma benzene hexachloride 1% w / v + cetrimide 0.1% w / v , gentamicin antibiotic disc , giemsa stain 25 mg. , glacial acetic acid , glucose test kit , glucose 6 phosphate dehydrogenase test kit , glucostix [ one glucometer must be supplied free of cost per 500 strips of glucostix ] , gluteraldehyde solution 2% for instrument sterilisation , glycerin i.p. , glycin irrigation fluid , gram stain kit , h2s strip kit , haemodialysis fluid with bi carb , hamatoxyllin eosin stain powder , hand disinfactant : each 100 gm soln.contains : 2 propanol 45g, 1 propanol 30g, ethyl hexadecyl dimethyl ammonium ethyl sulphate 0.2 g , hand rub soln.: 0.5% w / v chlorhexidine gluconate & 70 % v / v ethanol , hba1ctest kit , hbsag ( elisa ) kit specification: 1. microplate elisa coated with monoclonal antibodies to hbsag. 2. the assay should be able to detect surface antigen to hepatitis b virus. 3. adequate documents detailing the principle, components, bio safety, methodologies, validity criteria, interpretation of results, performance characteristics, storage conditions limitation of assays, manufacturing & expiry dates should be provided with each kit. 4. the kit to be procured should have approval of the statutory authority in its country of origin. 5. in case of imported kits it should have been registered and licensed in india by dcg ( i ) . 6. in case of indigenous manufacturers they shall have license issued by the competent authority defined under drugs and cosmetics act, 1940, after appropriate evaluation by the centers approved by dcg ( i ) . 7. the kit should have minimum shelf life of 60% or 12 months ( whichever is more ) at the port of discharge of consignees. 8. the assay component should include reactive and non reactive controls. 9. the assay should have sensitivity of more than or equal to 99% and specificity of more than or equal to 98% 10. the assay should have analytical sensitivity of detecting less than or equal to 0.5ng / ml. 11. the manufacturer / authorized agent should ensure maintenance of cold chain during storage & transport the kits at 2°c 8°c . the cumulative time temperature indicator technology used should be pre qualified by who. 12. the kit size should be 96 tests / kit. 13. the item should be up graded from iii generation to iv generation test kitin the light of bts trg recommendation dated 12th january 2015. , hbsag ( rapid ) kit specification: 1.should be solid phase / particle coated with monoclonal antibodies to hbsag. 2.the assay should be able to detect surface antigen to hepatitis b virus. 3. adequate documents detailing the principle, components, bio safety, methodologies, validity criteria, interpretation of results, performance characteristics, storage conditions, limitation of assays, manufacturing & expiry dates should be provided with each kit. 4. the kit to be procured should have approval of the statutory authority in its country of origin. 5. in case of imported kits it should be registered and licensed in india by dcg ( i ) . 6. in case of indigenous manufacturers they should be licensed by the competent authority defined under drugs and cosmetics act, 1940, after appropriate evaluation by the centers approved by dcg ( i ) . 7. the kit should have minimum shelf –life of 60% or 12 months ( whichever is more ) at the port of discharge of consignees. 8. the total procedure time shall not be more than 30 minutes. 9. the assay component should include positive and negative control in each pack of 50 tests. 10. the assay should have sensitivity of more than or equal to 99% and specificity of more than or equal to 98%. 11. the assay should have analytical sensitivity of detecting less than or equal to 0.5ng / ml. 12. the manufacturer / authorized agent should ensure maintenance of cold chain during storage & transport the kits at 2°c 8°c . the cumulative time temperature indicator technology used should be pre qualified by who. 13. the pack size should not be more than 50 tests wherein each test in individually packed. 14. the item should be up graded from iii generation to iv generation test kitin the light of bts trg recommendation dated 12th january 2015. , hcv ( elisa ) kit specification: 1. microplate elisa coated with recombinant / synthetic peptide antigens for core, ns3, ns4 and ns5. 2. adequated documents detailing the principle, components, bio safety, methodologies, validity criteria, interpretation of results, performance characteristics, storage conditions, limitation of assays , manufacturing & expiry dates should be provided with each kit. 3. the kit to be procured should have approval of the statutory authority in its country of origin. 4.in case of imported kits it should have been registered and licensed in india by dcg ( i ) . 5.in case of indigenous manufactures they shall have license issued by the competent authority defined under drugs and cosmetics act, 1940, after appropriate evaluation by the centers approved by dcg ( i ) . 6.the kits should have minimum shelf life of 60% or 12 months ( whichever is more ) at the port of discharge of consignees. 7. the assay component should include reactive and non reactive controls. 8.the assay should have a sensitivity more than or equal to 99% and specificity of more than or equal to 98%. 9.the manufacturer / authorized agent should ensure maintenance of cold chain during storage & transport the kits at 2°c 8°c. the cumulative time temperature indicator technology used should be pre qualified by who. 10. the kit size should be 96 test / .kit. 11. the item should be up graded from iii generation to iv generation test kitin the light of bts trg recommendation dated 12th january 2015. , hcv ( rapid ) kit specification: 1.should be solid phase / particle coated with recombinant and / or synthetic peptide antigens for core, ns3, ns4 and ns5. 2. adequate documents detailing the principle, components, bio safety, methodologies, validity criteria, interpretation of results, performance characteristics, storage conditions, limitation of assays, manufacturing & expiry dates should be provide with each kit. 3. the kit to be procured should have approval of the statutory authority in its country of origin 4. in case of imported kits it should have been registered and licensed in india by dcg ( i ) . 5. in case of indigenous manufactures they should be licensed by the competent authority defined under drugs and cosmetics act, 1940, after appropriate evaluation by the centers approved by dcg ( i ) . 6.the kit should have minimum shelf life of 60% or 12 months ( whichever is more ) at the port of discharge of consignees. 7.the total procedure time shall not be more than 30 minutes. 8. the assay component should include positive and negative control in each pack of 50tests. 9.the assay should have sensitivity of more than or equal to 99% and specificity or more than or equal to 98%. 10. the manufacture / authorized agent should ensure maintenance of cold chain during storage & transport the kits at 2°c 8°c. the cumulative time temperature indicator technology used should be pre qualified by who. 11. the pack size should not be more than 50 tests wherein each test is individually packed. 12.the item should be up graded from iii generation to iv generation test kitin the light of bts trg recommendations dated 12th january 2015. , hdl cholesterol d ( immunoterbedimetric ) test kit , hepatitis a test kit , hepatitis etest kit , hiv ( elisa ) kit specification: 1. should be solid phase microplate coatedhivi & ii recombinant and / or synthetic peptide antigens. 2. the assay should detected hiv 1 and ii antibodies. 3. adequate documents detailing the principal, components, details of antigen for antibody detection of hiv 1and 2, bio safety, methodologies, validity criteria, interpretation of results, performance characteristics, storage condition, limitation of assays, manufacturing & expiry dates should be provide with each kit. 4.the kit should have approval of the statutory authority in its country of origin. 5.in case of imported kits it should be registered and licensed in india by dcg ( i ) 6. in case of indigenous manufacturers should be licensed issued by the competent authority defined under drugs and cosmetics act, 1940 & also be evaluated by the centers approved by dcg ( i ) 7.the kitshould have minimum shelf life of 60% or 12 months ( whichever is more ) at the port of discharge of consignees . 8.the assay component should includ reactive and non reactive controls with each kit. 9.the assay should have sensitivity level of more than or equal to 99.5% and specificity level of more than or equal to 98%. 10.the manufacture / authorized agent should ensure maintenance of cold chain during storage and transport the kits at 2°c 8°c . the cumulative time temperature indicator technology used should be pre qualified by who. 11. the pack size should be 96 tests / kit. 12.the item should be up graded from iii generation to iv generation test kitin the light of bts trg recommendation dated 12th january 2015. , hiv ( rapid ) testing kits [ by principal of enzyme immuno assay, agglutination, or any other principle ] specification : 1. should be a solid phase coated hiv i & hiv ii recombinant and / or synthetic peptide antigens. 2. the assay should detect hiv i & ii antibodies in plasma, serum or whole blood. 3. adequte documents detailing the principle , components, details of antigen for antibody detection of hiv i & ii, bio safety, methodologies, validity criteria, interpretation of results, performance characteristics, storage conditions, limitation of assays, manufacturing & expiry dates should be provided with each kit. 4. the kit should have approval of the statutory authority from the country of origin. 5. in case of imported kits it should be registered and licensed by dcg ( i ) . 6. in case ofindigenous manufacturers should be licensed by the competent authority defined under drugs and cosmetics act 1940, also be evaluated by the centers approved by dcg ( i ) . 7.the kit should have minimum shelf life of 60% or 12 months ( whichever is more ) at the port of discharge of consignees. 8. the time required for performing the test should not be more than 30 minutes. 9.the control dot / band should be able to detect the presence of human immunoglobulins and should not be just a “procedural control” or meant for merely checking the flow of reagents or integrity of the antigen. 10. the assay should have sensitivity of more than or equal to 99.5% and specificity of more than or equal to 98%. 11.the manufacturers should ensure that : a. the test kit should be packed such that there is a provision to conduct single test at a time; b. the assay components should include hiv positive and negative serum control sufficient for conducting 20% of the tests ( 10% negative and 10% positive controls ) ;and c. the pack size of hiv rapid test kits should not be more that 50 tests per kit. 12. the manufacturer / authorized agent should ensure maintenance of cold chain during storage & transport the kits at 2°c 8°c. the cumulative time temperature indicator technology used should be pre qualified by who. 13. the item should be up graded from iii generation to iv generation test kitin the light of bts trg recommendation dated 12th january 2015. , hscrp test kit , hydrogen peroxide 11% w / v +diluted silver nitrate 0.01% w / v , hydrogen peroxide soln. ( 20vol ) i.p. , imipenem / cilastatin antibiotic disc , immersion oil , indole strip , iodine crystal , a.r. , isoprophyl alcohol ip 70% v / v , kanamycin antibiotic disc , kit for early diagnosis of pregnancy by immunological method ( hcg ) , koh solution 10% l , lactate test kit , ldh , ldl direct diagnostic kit , leishman stain soln. , levofloxacin antibiotic disc , lh kit elisa , lincomycin antibiotic disc , lineazolid antibiotic disc , lipase test kit , liquid paraffin i.p. ( heavy ) , liquified phenol i.p. ( carbolic acid ) , lomefloxacin antibiotic disc , mac conkey agar , magnesium sulphate i.p. , malachite green , mb / bact antibiotic suppliment kit , meropenem antibiotic disc , methyl alcohol , methyl violet , methylene blue liquid , methylene blue powder , micro protein test kit , minocyclin antibiotic disc , moxifloxacin antibiotic disc , mueller hintone agar , multistrips 8 parameter ( alb, glucose, ph, ketone, blood, bilirubin, urobilinogen & nitrite ) , muritic acid , nalidixic antibiotic disc , netilmycin antibiotic disc , nitric acid , nitrofurantoin antibiotic disc , norfloxacin antibiotic disc , o.t.sterilization solution for fumigation / mopping, in powder form, composition : potassium mono per sulphate ( triple salt ) 40% to 50 %, sodium c 10 13 alkyl benzene sulphate 10% to 20% and sodium chloride 1% to 5%. , ofloxacin antibiotic disc , paraffin wax 58 c to 60 c , paraffin wax 60 c x 62 c , penicillin antibiotic disc , peptone , ph paper range 1 to 14 , piperacillin antibiotic disc , pipercillin tazobactam antibiotic disc , poly sodium citrate , potassium iodide , potassium permanganate i.p. , ppa media , primary antibody er , primary antibody her , primary antibody pr , progesterone elisa kit , prolactin elisa , providone iodine cleansing solution 7.5% w / v surgical scrub , pt reagent , purified water i.p. , pyr reagent , pyr strip , rapid diagnostic kit for kala azar ( rk 39 ) , rheumatoid factor ( immunoterbedimetric ) test kit , rifampicin antibiotic disc , roxithromycin antibiotic disc , rpr ( rapid plasma reagin ) kit specification: 1. the indigenous rpr ( rapid plasma reagin ) kits should have been manufactured under manufacturing license issued by the state licensing authority under the drugs and cosmetics act. the imported kits should have been imported under import license issued by the dcg ( i ) under drugs and cosmetics act. 2. the assay should allow for qualitative and semi quantitative determination of reagin antibodies in serumor plasma for sero diagnosis of syphilis based on flocculation principle using non treponemal antigens. 3.the assay should be suitable to perform with either serum or plasma 4.the assay should have sensitivity of 85% or more in primary syphilis and a specificity of 93% or more. 5.the assay should be calibrated to who reference serum and the same should be supported by statements in kit insert and certificate from manufacturer. 6.the test should be able to yield results within 20 minutes. 7.the pack size of rpr test kit should be less than or equal to 50 tests per kit. 8.the assay components should include positive and negative serum control sufficient for conducting 20% of the tests ( 10% negative and 10% positive controls ) . 9. the kit should have all essential accessories required for the test such as cards, droppers, applicator etc. in adequate quantities for the number of tests to be performed. 10.the kit should have minimum shelf life of 60% or 12 months ( whichever is more ) at the port of discharge of consignees. 11. the cumulative time temperature indicator technology used should be pre qualified bywho. 12. literature, detailing the components, methodologies, validity criteria, performance characteristics, storage conditions, manufacturing and expiry dates should be provided with each kit. 13. the item should be up graded from iii generation to iv generation test kitin the light of bts trg recommendation dated 12th january 2015. , sabouraud dextrose agar ( sda ) with cc , serum billirubin test kit , sgot test kit , sgpt test kit , simmons citrate agar , sodium hypochloride – 500 ml bot. , solution for instrumental sterilization in powder form, composition : sodium perborate monohydrate 50% w / w ( 0.26% per acetic acid ) , sparfloxacin antibiotic disc , streptomycin antibiotic disc , surface disinfactant soln ( each 100 gm contains: 1, 6 di hydroxy 2, 5 di oxyhexane ( chemically bound formaldehyde ) 11.2 gms , glutaraldehide 5 gm , benzalkonium chloride 5 gm, alkyl urea derivatives 3 gms , t4 elisa , tcbs agar , teicoplanin antibiotic disc , tetracyclin antibiotic disc , ticarcillin / clavulanic acid antibiotic disc , tobramycin antibiotic disc , toludine blue , total protein test kit...

Northeast Frontier Railway - West Bengal

29354841 supply of set of 3 yly ovh kit for maintenance of sil make, air dryer. each kit consisting of 07items, in 09 nos. ( 1 ) filter coalescing sil drg no.09870601 webco pt. no.653298 qty / per 01 nos. ( 2 ) nut3 / 8set of 3 yly ovh kit for maintenance of sil make, air dryer. each kit consisting of 07 items, in 09 nos. ( 1 ) filter coalescing sil drg no.09870601 webco pt. no.653298 qty / per 01 nos. ( 2 ) nut3 / 8, set of 3 yly ovh kit for maintenance of sil make, air dryer. each kit consisting of 07 items, in 09 nos. ( 1 ) filter coalescing sil drg no.09870601 webco pt. no.653298 qty / per 01 nos. ( 2 ) nut3 / 8 hex lock sil drg no.71115603 webco pt. no.569374 qty / per 01 nos. ( 3 ) washer 3 / 8 lock self sealing sil drg no.09870701 webco pt. no.6401300001 qty / per 01 nos. ( 4 ) o ring 4.237 sil drg no.09872644 webco pt. no.590013 qty / per 01 nos. ( 5 ) kit for humidity indicator rebuild sil drg no.09891301 webco pt. no.304338 qty / per 02 nos. ( 6 ) repair kit drain valve sil drg no.09891101 webco pt. no.309112 qty / per 02 nos. ( 7 ) repair kit purge valve sil drg no.09891201 webco pt. no.309113 qty / per 02 nos. ( 8 ) o ring 1 / 2 od, sil drg no. 09872642= 02 nos. ( 9 ) o ring 2 od, sil drg no. 09872641= 01 no. ( 10 ) o ring 1.739 id, sil drg no. 09872642= 04 nos. ( 11 ) o ring 4.237 id, sil drg no 09872644= 08 nos. ( 12 ) o ring 4.4487 id, sil drg no 09872645= 04 nos. ( 13 ) o ring 6 id, sil drg no 09872646= 04 nos. ( 14 ) gasket flanger 1 sil drg no. 09872741= 06 nos. ( 15 ) desiccant element sil drg no. 09890901= 02 nos....

Northeast Frontier Railway - West Bengal

29002048 supply of kit for desiccant compactor for gm loco for faively make air dryer as per faiveley part no. 790029205.kit for desiccant compactor for gm loco for faively make air dryer as per faiveley part no. 790029205., kit for desiccant compactor for gm loco for faively make air dryer as per faiveley part no. 790029205....

Eastern Railways - West Bengal

28729599 supply of ioh kit of spares ( as / m48 ) of m / s trident make air dryer consist of 14 itemsioh kit of spares ( as / m48 ) of m / s trident make air dryer consist of 14 items, ioh kit of spares ( as / m48 ) of m / s trident make air dryer consist of 14 items as per following.1. filter element kit trident drg pt no ad433 qty / set=01 no. 2.filter top cup trident drg pt no cd668 qty / set=01 no.3filter bottom cup trident drg pt no cd669 qty / set=01 no.4.spare kit filter bottom trident drg pt no ad443 qty / set=01 no.5.spare valve double poppet kit trident drg pt no as444 qty / set=01 no.6.filter elementm25oy trident drg pt no ac077 qty / set=01 nos7.spare kit valve shuttle trident drg pt no as706 qty / set=01 nos8.spare kit valvepurge trident drg pt no as446 qty / set=02 nos9.bag cartidge desiccant trident drg pt no cd671 qty / set=02 nos10.spring compactort trident drg pt no cd673 qty / set=02 nos11.spare kit seal tower trident drg pt no as447433 qty / set=01 no.12.sub assy humidity indicator trident drg pt no ad925 qty / set=02 nos13.gasket pad amisco solenoid valve trident drg pt no as079a qty / set=02 nos.14.seal kit controller box trident drg pt no as079 qty / set=01 no....

Indian Army - West Bengal

28397498 procurment of medical stores 2 blood urea nitrogen ( bun / urea ) 3 ceeatinine idms ( crea idms ) 4 potassium ( k+ ) 5 sodium ( na+ ) 6 alanine aminotranaferase 9 altv ) 7 albimin ( alb ) 8 alkaline phosphatase ( alkp ) 9 aspartate aminotransferase ( ast ) 10 bilirubin , unconjugated and conjugated ( bubc ) 11 gamma glutamyltransferase ( ggt ) 12 total bilirubin ( tbil ) 13 total protein ( tp ) 14 cholesterol ( chol ) slides 15 direct hdl cholesterol ( dhdl ) 16 triglyceride ( trig ) 17 creatine kinase ( ck ) 18 creatine kinase mb ( ckmb ) 19 lactate dehydrogenase ( ldh ) 20 calcium ( ca ) 21 lithium ( li ) 22 lipase ( lipa ) 23 cerebrospinal fluid ( csf ) protein ( prot ) 24 glucose ( glu ) 25 uric acd ( uric ) 26 urine protein ( upro ) 27 microalbumin ( malb ) 28 calibrator kit 1 bun / urea, ca, crea, glu, lac, li, mg, phos, sali, theo, uric 29 calibrator kit 2 chol, cl eco2, k+, na+, trig 30 calibrator kit 3 acp, alt, alkp, ayl, ast, ck, ggt, ldh, lipa 31 calibrator kit 4 alb, bubc, fe, tbil, tibc, tp 32 calibrator kit 5 amon prot 33 calibrator kit 6 che, ckmb 34 calibrator kit 10 upro 35 calibrator kit 25 dhdi 36 calibrator kit 31 37 calibrator kit 24 malb 38 isoenzyme performance verifier i 39 isoenzyme performance verifier ii 40 liquid performance verifer i 41 liquid performance verifer ii 42 performance verifer i 43 malb performance verifer i 44 malb performance verifer ii 45 reference fluid 800 46 f s humidification pack 47 desiccant pack 48 upro performance verified ii 49 upro performance verified ii 50 fs reconstitution diluent 51 micro sensor check fluids i &ii 52 fs diluent pack 2 ( bsa / saline ) 53 fs diluent pack 3 ( specialty diluent / water ) 54 fs micro tip 55 fs cuvettes 56 micro samples cups ( 0.5ml ) 57 versa tip 58 phosphorus ( phos ) 59 performance verifier ii...

Northeast Frontier Railway - West Bengal

27390019 supply of air dryer maintenance kit consisting of 17 items ( qty in per kit ) >1 ) kit for precoalescer ftil pt no790029165=1no, 2 ) kit for regenerating orifice ftil pt no790029111=1no, 3 ) kit for final filter ftil pt no790029125=1no, 4 ) kit for desiccant canister ftil pt no790029195 =2nos, 5 ) kit for humidity indicator ftil pt no790029105=2nos, 6 ) kit for inlet check valve ftil pt no790029135=2nos, 7 ) kit for drain valve ftil pt no790029175=1no, 8 ) kit for outlet check valve ftil pt no790029145=2nos, 9 ) kit for purge valve ftil pt no790029185=2nos, 10 ) kit for solenoid valve ftil pt no790029155=2nos, as per drg.no. 11 ) kit fordesiccant compactor ftil pt no 790029205air dryer maintenance kit consisting of 17 items ( qty in per kit ) >1 ) kit for precoalescer ftil pt no790029165=1no, 2 ) kit for regenerating orifice ftil pt no790029111=1no, 3 ) kit for final filter ftil pt no790029125=1no, 4 ) kit for desiccant canister ftil pt no790029195 =2nos, 5 ) kit for humidity indicator ftil pt no790029105=2nos, 6 ) kit for inlet check valve ftil pt no790029135=2nos, 7 ) kit for drain valve ftil pt no790029175=1no, 8 ) kit for outlet check valve ftil pt no790029145=2nos, 9 ) kit for purge valve ftil pt no790029185=2nos, 10 ) kit for solenoid valve ftil pt no790029155=2nos, as per drg.no. 11 ) kit fordesiccant compactor ftil pt no 790029205, air dryer maintenance kit consisting of 17 items ( qty in per kit ) >1 ) kit for precoalescer ftil pt no790029165=1no, 2 ) kit for regenerating orifice ftil pt no790029111=1no, 3 ) kit for final filter ftil pt no790029125=1no, 4 ) kit for desiccant canister ftil pt no790029195 =2nos, 5 ) kit for humidity indicator ftil pt no790029105=2nos, 6 ) kit for inlet check valve ftil pt no790029135=2nos, 7 ) kit for drain valve ftil pt no790029175=1no, 8 ) kit for outlet check valve ftil pt no790029145=2nos, 9 ) kit for purge valve ftil pt no790029185=2nos, 10 ) kit for solenoid valve ftil pt no790029155=2nos, as per drg.no. 11 ) kit fordesiccant compactor ftil pt no 790029205...

Eastern Railways - West Bengal

27335234 supply of dengue ns 1 ag elisa test kit, pack of 48 tests eachspecification:1. the elisa kit should be designed for qualitative detection of dengue ns1 antigen of all 4 dengue serotypes in human serum.2. the kit should be provided with the following materials and reagents:a. anti ns1 antibody coated breakway microwells. desiccant should be provided for storing the unused microwells which are to be resealed immediately.b. horseradish peroxidase conjugated anti ns1 monoclonal antibody with preservatives.c. chromogenic substrate in buffer.d. positive control in the form of recombinant antigen with preservatives and antibiotics.e. negative control in the form of confirmed negative human serum with preservatives and antibiotics.f. calibrators in the form of recombinant antigen with preservatives and antibiotics.g. sample diluents.h. wash buffer.3. the time required for performing the test for detection of dengue ns1 antigen by elisa should range between 2 4 hours.4. the elisa kit for detection of dengue ns1 antigen should have a sensitivity of >90% and a specificity of >95% taking rt pcr as the gold standard.5. the kit should have a shelf life of at least 18 months when stored at an ambient temperature of 2 degree c to 8 degree c.6. transportation should be under cold chain.7. demonstration should be done to the satisfaction of the user department.dengue ns 1 ag elisa test kit, pack of 48 tests each specification: 1. the elisa kit should be designed for qualitative detection of dengue ns1 antigen of all 4 dengue serotypes in human serum. 2. the kit should be provided with the following materials and reagents: a. anti ns1 antibody coated breakway microwells. desiccant should be provided for storing the unused microwells which are to be resealed immediately. b. horseradish peroxidase conjugated anti ns1 monoclonal antibody with preservatives. c. chromogenic substrate in buffer. d. positive control in the form of recombinant antigen with preservatives and antibiotics. e. negative control in the form of confirmed negative human serum with preservatives and antibiotics. f. calibrators in the form of recombinant antigen with preservatives and antibiotics. g. sample diluents. h. wash buffer. 3. the time required for performing the test for detection of dengue ns1 antigen by elisa should range between 2 4 hours. 4. the elisa kit for detection of dengue ns1 antigen should have a sensitivity of >90% and a specificity of >95% taking rt pcr as the gold standard. 5. the kit should have a shelf life of at least 18 months when stored at an ambient temperature of 2 degree c to 8 degree c. 6. transportation should be under cold chain. 7. demonstration should be done to the satisfaction of the user department., dengue ns 1 ag elisa test kit, pack of 48 tests each specification: 1. the elisa kit should be designed for qualitative detection of dengue ns1 antigen of all 4 dengue serotypes in human serum. 2. the kit should be provided with the following materials and reagents: a. anti ns1 antibody coated breakway microwells. desiccant should be provided for storing the unused microwells which are to be resealed immediately. b. horseradish peroxidase conjugated anti ns1 monoclonal antibody with preservatives. c. chromogenic substrate in buffer. d. positive control in the form of recombinant antigen with preservatives and antibiotics. e. negative control in the form of confirmed negative human serum with preservatives and antibiotics. f. calibrators in the form of recombinant antigen with preservatives and antibiotics. g. sample diluents. h. wash buffer. 3. the time required for performing the test for detection of dengue ns1 antigen by elisa should range between 2 4 hours. 4. the elisa kit for detection of dengue ns1 antigen should have a sensitivity of >90% and a specificity of >95% taking rt pcr as the gold standard. 5. the kit should have a shelf life of at least 18 months when stored at an ambient temperature of 2 degree c to 8 degree c. 6. transportation should be under cold chain. 7. demonstration should be done to the satisfaction of the user department....

Indian Army - West Bengal

26718513 procurement of ord stores , ord store , shoval hand light blade , handles powrah wooden , cloth muslin white bleached 91 cm wide , desiccant silica gel , tape adhesive transparent...

Indian Army - West Bengal

26186987 procurement of medical stores , drugs , blood urea nitrogen ( bun/urea ) , creatinine idms ( crea idms ) , potassium ( k+ ) , sodium ( na+ ) , alanine aminotransferase ( altv ) , alkaline phosphatase ( alkp ) , albumin ( alb ) , aspartate aminotransferase ( ast ) , bilirubin , unconjugated and conjugated ( bubc ) , gamma glutamyltransferase ( ggt ) , total bilirubin ( tbil ) , total protein ( tp ) , cholesterol ( chol ) slides , direct hdl cholesterol ( dhdl ) , triglyceride ( trig ) , creatine kinase ( ck ) , creatine kinase mb ( ckmb ) , lactate dehydrogenase ( ldh ) , calcium ( ca ) , lithium ( li ) , magnesium ( mg ) , amylase ( amyl ) , lipase ( lipa ) , ammonia ( amon ) , cerebrospinal fluid ( csf ) protein ( prot ) , glucose ( glu ) , uric acid ( uric ) , urine protein ( upro ) , microalbumin ( malb ) , calibrator kit 1 bub/urea , ca . crea , glu , lac , li , mg , phos , sali , theo , uric , calibrator kit 2 chol . cl eco2 , k+ , na+ , trig , calibrator kit 3 acp , alt , alkp , amyl , ast , ck , ggt , ldh , lipa , calibrator kit 4 alb , bubc , fe , tbil , tibc , tp , calibrator kit 5 amon , port , calibrator kit 6 che , ckmb , calibrator kit 10 upro , calibrator kit 25 dhdl , calibrator kit 31 , calibrator 24 malb , isoenzyme performance verifier i , isoenzyme performance verifier ii , liquid performance verifier i , liquid performance verifier ii , performance verifier i , performance verifier ii , malb performance verifier i , malb performance verifier ii , reference fluid 800 , fs humidification pack , desiccant pack , upro performance verifier i , upro performance verifier ii , fs reconstitution diluent , microsensor check fluids i & ii , fs diluent pack 2 ( bsa/saline ) , fs diluent pack 3 ( specialty diluent/water ) , fs micro tip , fs cuvettes , micro samples cups ( 0 . 5ml ) , versa tip , phosphorus ( phos ) ...

Indian Army - West Bengal

26088449 procurement of medical stores , drugs , blood urea nitrogen ( bun/urea ) , creatinine idms ( crea idms ) , potassium ( k+ ) , sodium ( na+ ) , alanine aminotransferase ( altv ) , alkaline phosphatase ( alkp ) , albumin ( alb ) , aspartate aminotransferase ( ast ) , bilirubin , unconjugated and conjugated ( bubc ) , gamma glutamyltransferase ( ggt ) , total bilirubin ( tbil ) , total protein ( tp ) , cholesterol ( chol ) slides , direct hdl cholesterol ( dhdl ) , triglyceride ( trig ) , creatine kinase ( ck ) , creatine kinase mb ( ckmb ) , lactate dehydrogenase ( ldh ) , calcium ( ca ) , lithium ( li ) , magnesium ( mg ) , amylase ( amyl ) , lipase ( lipa ) , ammonia ( amon ) , cerebrospinal fluid ( csf ) protein ( prot ) , glucose ( glu ) , uric acid ( uric ) , urine protein ( upro ) , microalbumin ( malb ) , calibrator kit 1 bub/urea , ca . crea , glu , lac , li , mg , phos , sali , theo , uric , calibrator kit 2 chol . cl eco2 , k+ , na+ , trig , calibrator kit 3 acp , alt , alkp , amyl , ast , ck , ggt , ldh , lipa , calibrator kit 4 alb , bubc , fe , tbil , tibc , tp , calibrator kit 5 amon , port , calibrator kit 6 che , ckmb , calibrator kit 10 upro , calibrator kit 25 dhdl , calibrator kit 31 , calibrator 24 malb , isoenzyme performance verifier i , isoenzyme performance verifier ii , liquid performance verifier i , liquid performance verifier ii , performance verifier i , performance verifier ii , malb performance verifier i , malb performance verifier ii , reference fluid 800 , fs humidification pack , desiccant pack , upro performance verifier i , upro performance verifier ii , fs reconstitution diluent , microsensor check fluids i & ii , fs diluent pack 2 ( bsa/saline ) , fs diluent pack 3 ( specialty diluent/water ) , fs micro tip , fs cuvettes , micro samples cups ( 0 . 5ml ) , versa tip , phosphorus ( phos ) ...

Indian Army - West Bengal

25292535 procurement of ordnance store (a) h1(b)/ 8040 000008, adhesive padding glue (mowicol ‘l’) (b) h1(b)/ 6850 000041, desiccant silica gel (c) f1/5120 000088, pliers side cutting 200mm (d) f1/5120 003046, spanner ring cracked double ended steel plated (mm) 19x22 (e) f1/5120 003044, spanner ring cracked double ended steel plated (mm) 12 x14 (f) f1/5120 000060, screw drivers new perfect 150 mm (g) f1/5120 001594,spanners ring bihexagon cranked double ended steel plated nominal width across flat size 10x11mm (h) h2/4020 000551,rope polypropylene 3 strand h/l og 6mm dia (j) h2/ 8305 000180,cloth dosutie cotton og 91cm wide (k) h4/9330 000026,polythene film 0.12 mm thick x 1 mtr width (l) f1/5120 001596, spanners ring bihexagon cranked double ended steel plated nominal width across flat size 14x15mm (m) f1/5210 000141, gauges thickness feeler type 100 mm...

Eastern Railways - West Bengal

24496961 supply of , dengue ns1 ag elisa kit, [pack of 48 tests] rate to be quoted per test basis 1) the elisa kit should be designed for qualitative detection of dengue ns1 antigen of all 4 dengue serotypes in human serum. 2) the kit should be provided with the following materials and reagents: a) anti ns1 antibody coated breakway microwells. desiccant should be provided for storing the unused microwells which are to be resealed immediately. b) horseradish peroxidase conjugated anti ns1 monoclonal antibody with preservatives c) chromogenic substrate in buffer d) positive control in the form of recombinant antigen with preservatives and antibiotics e) negative control in the form of confirmed negative human serum with preservatives and antibiotics f) calibrators in the form of recombinant antigen with preservatives and antibiotics g) sample diluents h) wash buffer 3) the time required for performing the test for detection of dengue ns1 antigen by elisa should range between 2 4 hours. 4) the elisa kit for detection of dengue ns1 antigen should have a sensitivity of >90% and a specificity of >95% taking rt pcr as the gold standard. 5) the kit should have a shelf life of at least 18 months when stored at an ambient temperature of 2 degree c 8 degreec. 6) transportation should be under cold chain. [item code s60098 sl no 634]...

Bidhan Chandra Krishi Viswavidyalaya - West Bengal

23611567 supply of equipment purchase for scientific research , electrical items : , steady state portable: leaf porometer steady state portable leaf porometer of leading brand which measures in 30 sec in auto mode with an accuracy of 10% of measurement in an operating environment of 5 400c , 0 100% rh with desiccant chamber , making an output through rs232 computer interface ....

Eastern Railways - West Bengal

23031168 supply of dengue ns 1 antigen(ag) elisa test kit. per test. specification: 1) the elisa kit should be designed for qualitative detection of dengue ns1 antigen of all 4 dengue serotypes in human serum. 2) the kit should be provided with the following materials and reagents: a) anti ns1 antibody coated breakway microwells. desiccant should be provided for storing the unused microwells which are to be resealed immediately. b) horseradish peroxidase conjugated anti ns1 monoclonal antibody with preservatives c) chromogenic substrate in buffer d) positive control in the form of recombinant antigen with preservatives and antibiotics e) negative control in the form of confirmed negative human serum with preservatives and antibiotics f) calibrators in the form of recombinant antigen with preservatives and antibiotics g) sample diluents h) wash buffer 3) the time required for performing the test for detection of dengue ns1 antigen by elisa should range between 2 4 hours. 4) the elisa kit for detection of dengue ns1 antigen should have a sensitivity of >90% and a specificity of >95% taking rt pcr as the gold standard. 5) the kit should have a shelf life of at least 18 months when stored at an ambient temperature of 2 degree c 8 degreec. 6) transportation should be under cold chain. 7) demonstration should be done to the satisfaction of the user department., dengue ns 1 antigen(ag) elisa test kit. rate must be quoted per test. specification: 1) the elisa kit should be designed for qualitative detection of dengue ns1 antigen of all 4 dengue serotypes in human serum. 2) the kit should be provided with the following materials and reagents: a) anti ns1 antibody coated breakway microwells. desiccant should be provided for storing the unused microwells which are to be resealed immediately. b) horseradish peroxidase conjugated anti ns1 monoclonal antibody with preservatives c) chromogenic substrate in buffer d) positive control in the form of recombinant antigen with preservatives and antibiotics e) negative control in the form of confirmed negative human serum with preservatives and antibiotics f) calibrators in the form of recombinant antigen with preservatives and antibiotics g) sample diluents h) wash buffer 3) the time required for performing the test for detection of dengue ns1 antigen by elisa should range between 2 4 hours. 4) the elisa kit for detection of dengue ns1 antigen should have a sensitivity of >90% and a specificity of >95% taking rt pcr as the gold standard. 5) the kit should have a shelf life of at least 18 months when stored at an ambient temperature of 2 degree c 8 degreec. 6) transportation should be under cold chain. 7) demonstration should be done to the satisfaction of the user department....

Eastern Railways - West Bengal

22358792 supply of dengue ns 1 antigen (ag) elisa test kit. specification: 1) the elisa kit should be designed for qualitative detection of dengue ns1 antigen of all 4 dengue serotypes in human serum. 2) the kit should be provided with the following materials and reagents: a) anti ns1 antibody coated breakway microwells. desiccant should be provided for storing the unused microwells which are to be resealed immediately. b) horseradish peroxidase conjugated anti ns1 monoclonal antibody with preservatives c) chromogenic substrate in buffer d) positive control in the form of recombinant antigen with preservatives and antibiotics e) negative control in the form of confirmed negative human serum with preservatives and antibiotics f) calibrators in the form of recombinant antigen with preservatives and antibiotics g) sample diluents h) wash buffer 3) the time required for performing the test for detection of dengue ns1 antigen by elisa should range between 2 4 hours. 4) the elisa kit for detection of dengue ns1 antigen should have a sensitivity of >90% and a specificity of >95% taking rt pcr as the gold standard. 5) the kit should have a shelf life of at least 18 months when stored at an ambient temperature of 2 degree c 8 degreec. 6) transportation should be under cold chain. 7) demonstration should be done to the satisfaction of the user department., dengue ns 1 antigen (ag) elisa test kit. specification: 1) the elisa kit should be designed for qualitative detection of dengue ns1 antigen of all 4 dengue serotypes in human serum. 2) the kit should be provided with the following materials and reagents: a) anti ns1 antibody coated breakway microwells. desiccant should be provided for storing the unused microwells which are to be resealed immediately. b) horseradish peroxidase conjugated anti ns1 monoclonal antibody with preservatives c) chromogenic substrate in buffer d) positive control in the form of recombinant antigen with preservatives and antibiotics e) negative control in the form of confirmed negative human serum with preservatives and antibiotics f) calibrators in the form of recombinant antigen with preservatives and antibiotics g) sample diluents h) wash buffer 3) the time required for performing the test for detection of dengue ns1 antigen by elisa should range between 2 4 hours. 4) the elisa kit for detection of dengue ns1 antigen should have a sensitivity of >90% and a specificity of >95% taking rt pcr as the gold standard. 5) the kit should have a shelf life of at least 18 months when stored at an ambient temperature of 2 degree c 8 degreec. 6) transportation should be under cold chain. 7) demonstration should be done to the satisfaction of the user department....

South Eastern Railways - West Bengal

22189327 supply of kit trident make air dryer etc., kit trident make air dryer: i] filter element pt no ad433 =01 no. ii] filter top cap pt no cd668 =01 no. iii] filter bottom cup pt no cd669 =01 no. iv] spare kit filter bottom pt no as443 =01 no. v] spare kit valve double poppet pt no as444 =01 no. vi] filter element m2050y pt no ac 077 =01 no. vii] spare kit valve shuttle pt no as708 or as445 or as706 =01 no. viii] spare kit valve purge as446 =02 nos. ix] bag cartridge desiccant pt no cd671 =02 nos. [x] spring compactor pt no cd673 =02 nos. [xi] spare kit seals tower as447 =01 no. [xii] sub assly humidity indicator pt noad925 =02 nos. [xiii] gasket pad amisco solenoid valv pt no as079a =02 nos. [xiv]spare kit seals controller pt no as709 =01. [14 items in one set)...

South Eastern Railways - West Bengal

21935432 supply of air dryer maintenance kit ( 5 items ) ( ftil make ) etc., air dryer maintenance kit ( 5 items ) ( ftil make ) , inlet man coalescer kit ( ad ) , pt no. 790029165 ( 1 set ) ( rc ) desiccant canister kit ( ad ) pt no. 790029195 ( 1 set ) ( rc ) , humidity indicator kit ( ad ) , pt no. 790029105a ( 1 set ) ( rc ) , final filter kit, pt no. 790029125 ( 1 set ) ( rc ) , regenerating orifice kit ( ad ) , pt no. 790029111 ( 1 set ) ( rc ) ...

Northeast Frontier Railway - West Bengal

21744120 supply of trident make air dryer poh kit consisting of 13 items , (1) filter element,part no: ad433 01 no. (2)filter top cup , part no: cd668 01no. (3) filter bottom cup, part no: cd669 01 no. (4) spare kit filter bottom , part no: as443 01no. (5) sapre kit valve double poppet, part no: as444 01 no. (6)spare kit valve shuttle , part no: as445 01 no. (7)spare kit valve purge, part no: as446 02 nos. (8)bag cartridge desiccant, part no: cd671 02nos. (9) spring compactor, part no: cd673 02 nos. (10)spare kit seals tower , part no: as447 01 no. (11)sub assy humidity indicator , part no: ad925 02 nos. (12) gasket pad amisco solenoid valve, part no: as079a 02 nos. (13) spare kit seals controller box , part no: as709 01no. ., trident make air dryer poh kit consisting of 13 items , (1) filter element,part no: ad433 01 no. (2)filter top cup , part no: cd668 01no. (3) filter bottom cup, part no: cd669 01 no. (4) spare kit filter bottom , part no: as443 01no. (5) sapre kit valve double poppet, part no: as444 01 no. (6)spare kit valve shuttle , part no: as445 01 no. (7)spare kit valve purge, part no: as446 02 nos. (8)bag cartridge desiccant, part no: cd671 02nos. (9) spring compactor, part no: cd673 02 nos. (10)spare kit seals tower , part no: as447 01 no. (11)sub assy humidity indicator , part no: ad925 02 nos. (12) gasket pad amisco solenoid valve, part no: as079a 02 nos. (13) spare kit seals controller box , part no: as709 01no. ....

South Eastern Railways - West Bengal

21739130 supply of air dryer maintenance kit (5 items) (ftil make) etc., air dryer maintenance kit (5 items) (ftil make) , inlet man coalescer kit(ad), pt no. 790029165 (1 set) (rc) desiccant canister kit (ad) pt no. 790029195 ( 1 set) (rc), humidity indicator kit (ad), pt no. 790029105a ( 1 set) ( rc), final filter kit, pt no. 790029125 ( 1 set) (rc), regenerating orifice kit (ad), pt no. 790029111 ( 1 set) ( rc)...

Steel Authority Of India Limited - West Bengal

21518443 lithium bromide water solution lithium bromide water solutionchem. formula libr; chem. family inorganic bromide; mol wt 86.85;typeof product and use inorganic sol used as desiccant medium in airconditioning and cooling systems. libr: 53 55%(wt.) water: 45 47%(wt.);pack size 100 or 200 kg shelf life: 5 years; commercial grade labelinformation: 1. suppliers monogram 2. chemical specifications 3. a/tno. 4. content volume 5. date of manufacture 6. grade...

South Eastern Railways - West Bengal

20657529 tender for air dryer maintenance kit (5 items) (ftil make) , inletman coalescer kit(ad), pt no 790029165,(1set)item list : (1) air dryer maintenance kit (5 items) (ftil make) , inletman coalescer kit(ad),pt no 790029165,(1set); desiccant canister kit(ad) pt no 790029195 (1set); humidityindicator kit(ad), pt no : 790029105a (1set); final filter kit, pt no : 790029125 (1set);regenarating orifice kit (ad) pt no: 790029111 (1set).diesel loco shed store odisha 31.00 setdepotdiesel loco shed jharkhand 11.00 setstores depot...

Public Health Engineering Department - West Bengal

20415035 supplying installation and commissioning of new desiccant compressed air dryers (heatless type) at the filter house of 34mgd water treatment plant in dakshin roypur under surface water based water supply scheme in the arsenic affected area of south 2, 01/2019 2020/ee/swd i/wbphed/2=> open tender...

West Bengal State University - West Bengal

20387342 supply and installation of spares of existing perkin elmer india ltd. instruments for the dept. of chemistry, west bengal state university, barasat, supply and installation of spares of existing perkin elmer india ltd. instruments for the dept. of chemistry, wbsu, barasat 1.01 tooth belt 120z.6t2 / 240 1.02 tungsten halogen lamp assembly 1.03 elp uv lamp complete 1.04 filter wheel glued l20 40p 1.05 source assembly for ls30l40l50 1.06 festoon lamp ls2 12v / 3w 1.07 stepper motor 1.08 stepper motor rdm 3716 1.09 spectrum 2 kbr windows kit 1.1 spectrum 2 desiccant replacement kit 1.11 sp2 source replacement kit=> single...

Aliah University - West Bengal

20340982 supply of antibodies, proteins and resins purity, (75493, 5 g) b22 o phenylenediamine (opd), peroxidase substrate, ≥98.0%, powder (p9029, 50 g) b23 sodium oleate (oleic acid sodium salt), o7501, 250 mg c1 sephacryl s100 (s100hr) c2 sephacryl s200 (s200hr) c3 sephadex g50 (g2580) c4 sephadex g75 (g50150) c5 sepharose 4b or seralose 4b (sigma/srl) c6 silica gel desiccant (self indicating blue coarse water absorbing capacity) c7 silica gel for column (60 120) c8 deae cellulose, analyical grade for molecular biology, (srl)...

Council Of Scientific And Industrial Research - West Bengal

19039633 spares and consumables for atlas copco zt90 compressor and cdx drier part description 1. 2906066400 zr / t55 90 air / oil filter kit 2. 2901063300 set wearing parts ewd33o, 1500c 3 1089064044 solenoid valve 4 2906065900 zr / t 5 5 90 inlet vlv serv kit roto z can 20l . spares_required for_cdx 3so 5 2908850101 sl. no. part no. 1 2 9095049840 2901200308 desiccant kit cdx 350 ( 205kgj filter kit dd310+...

Indian Railway - West Bengal

18421228 tender for kit consisting of 49 item sfor air dryer unit, ltz 015, kb part no. ii48031/13110.compression spring b80465 2nos, compression spring c59204 1no, compressionspring b35531 2nos, compression spring b82679 1no, round wire netting b27807 4nos,sealing ring 453783 2nos, sealing ring 453790 1no, sealing ring 453807 2nos, sealingring 456999 2nos, o ring b24036 2nos, compression spring c65798 1no, compressionspring b85028 2nos, o ring b21928 2nos, o ring b21858 6nos, locking ring 466059 8nos,hexagon nut 468086 2nos, locking ring 466058 2nos, o ring a40125/20 2nos, knorr k ring 454953 2nos, retaining ring 467044 2nos, o ring a40125/13 2nos, o ring a52320 2nos,toothed ring a62331/2 3nos, o ring a91453 2nos, scraper ring a97200/5 2nos, o ring b44910 2nos, knorr k ring 462422 2nos, sealing ring 459633 1no, o ring a79532 2nos, o ring b51209 2nos, o ring a40791 2nos, o ring a64261 1no, o ring a83273 1no, o ring b24149 1no, o ring b58177 2nos, gasket b70677 1no, knorr k ring 462615 1no, locking ring 466884 4nos, locking ring 468204 3nos, scraper ring a97200/7 2nos, knorr k ring 458906 2nos, retaining ring 464255 2nos, o ring b55436 4nos, filter element 1.3.3085/6 1no,sealing ring 466686 2nos, o ring c124266/1 4nos, toothed ring a62331/2 1no, desiccant(4kgper vessel) 503329 2nos, washer 466232/n3502222x 2nos....

Indian Railway - West Bengal

18408229 tender for 3 yly ovh kit for stone india make air dryer ( m 48 schedule ) consisting of 17 nos.: 1 ) . nut 3 / 8 16 hex lock, sil drg.no.71115603 = 01 no. 2 ) . filter cialescing , sil drg.no. 09870601 = 01 no. 3 ) . washer 3 / 8 lock self sealing sil drg.no 09870701 = 01 no. 4 ) . o ring 2 od , sil drg.no 09872641 = 01 no. 5 ) . o ring 1 / 2 od , sil drg.no. 09872642 = 02 nos. 6 ) . o ring 1.739 id sil drg.no. = 04 nos. 7 ) . o ring 4.237 id sil drg.no. 09872644 = 08 nos. 8 ) . o ring 4.4487 id sil drg.no. 09872645 = 04 nos. 9 ) . o ring 6 id sil drg.no.09872646 = 04 nos. 10 ) .gasket flangr 1 sil drg.no.09872741 = 06 nos. 11 ) .gasket flange 3 / 8 sil drg.no.09872742 = 03 nos. 12 ) .check valve seal sil drg.no.09876501 = 02 nos. 13 ) .valve solenoid 110 v, d.c sil drg.no. 09883501 = 02 nos. 14 ) .desiccant element sil drg.no. 09890901 = 02 nos. 15 ) .repair kit drain valve sil drg.no.09891101 = 02 nos. 16 ) .repair kit purge valve sil drg.no 09891201 = 01 no. 17 ) .kit humidity indicator rebuild sil drg.no.09891301 = 02 nos...

Health And Family Welfare Department - West Bengal

18328437 tender for procurement and purchase of rntcp consumables for health programmes : 1.13 water bath with thermometer with digital temp. metar, 5 liter for the preparation of carbol fucshnn, company name linga 1.14 lens tissue paper100 page pack. company name indica 1.15 tray paastic ( big ) 24t x1z. good quality 1.16 spirtt lamp alumnnium, 5oml. agarwal crockery & scientific stores 1.17 drop bottles plastic 100 ml capacity company name polyaab 1.18 storage for stock bottle ( plastic ) whtte bottles 2 ltrs. capacity company name polyaab 1.19 bnnocuaar microscope cover plastic good quality, company name: leica 1 2 balance wtth cover box ( digttal & electrical ) can measure 10 mg accuracy to 200 gm capacity. 1.21 plastic loop ( 89 bundle of 100 pcs. 1.22 slide box ( 50 capacity ) plastic, company name polylab 1.23 slide box ( 100 capacity ) plastic, company name polylab 1.24 glass rod, 6 8 mm dia x 20 length company name blue star 1.25 glass slide new glass slides, i.e. size: 76 mm x 26 mm, ii. thickness: 1.3 mm, iii. edges: polished, iv. sealed in a moisture absorbing desiccant pack company name blue star i .26 thermocol box size: outside 2s5mm ( l ) x21 smm ( w ) x21 smm ( h ) size: lntside 200mm ( l ) xl 65mm ( w ) x1 55mm ( h ) weight 1 55 gms. 1.27 stop watch digttal good quality. company name racer 1.28 silica gel big ( 25 gm. ) conpany name loba i .29 silica gel blue small ( 04 gm. ) company name loba...

Eastern Coal Fields Ltd - West Bengal

16866150 rate contract for 02 years of eh600 model dumper spares: 55 spacer (part no: e6244381) 56 gear annulus (part no: e12632202) 57 sun gear (part no: e12631186) 58 cir clip (part no: e9413412) 59 seal face (part no: e14001776) 60 dowel pin (part no: e12978427) 61 flange 12 point screw 0.75x16 2.25l (part no: e13813945) 62 o ring 378 (part no: e13814055) 63 sealant, purple 300ml std31262,515 (part no: e4063063) 64 o ring (part no: e13813919) 65 o ring 269 viton 90 duro (part no: e13814054) 66 dowel pin (part no: e12631116) 67 a ring (part no: e13813093) 68 a ring (part no: e13813130) 69 dowel pin, 1/4 x 0.88 hrd (part no: e13814117) 70 back up ring (part no: e13807065) 71 dowty bonded washer (part no: e12977499) 72 back up ring (part no: e13807067) 73 a ring (part no: e13813128) 74 circlip (part no: e9413412) 75 anti seeze copper (part no: e13813826) 76 spacer (part no: e12631690) 77 sleeve (part no: e12631544) 78 disc; friction (part no: e14001397/ e12646496) 79 plate; reaction (part no: e14001398 / e12646494) 80 differential pinion bush (part no: e12637163) 81 differential pinion (part no: e6231135) 82 thrust washer (part no: e11993487) 83 differential wheel spacing washer (part no: e6231147) 84 differential bevel wheel (part no: e12631165) 85 differential bevel wheel (part no: e12631166) 86 thrust washer (part no: e6231145) 87 differential bevel wheel bush (part no: e6231158) 88 diff. cage bolt (part no: e12637185) 89 lock nut (part no: e13806851) 90 bearing cup (part no: e14500068) 91 bearing cone (part no: e14500069) 92 differential pinion brg. (part no: e12638832) 93 external circlip (part no: e6231159) 94 bearing cup (part no: e14500066) 95 bearing cone (part no: e14500067) 96 oil seal (part no: e6244376) 97 seal spacer (part no: e6237629) 98 o ring (part no: e13813116) 99 desiccant catridge kit (part no: e12980040) 100 check valve (part no: e14000841) ...

Eastern Coal Fields Ltd - West Bengal

16639502 rate contract for 02 years of eh600 model dumper spares: 55 spacer (part no: e6244381) 56 gear annulus (part no: e12632202) 57 sun gear (part no: e12631186) 58 cir clip (part no: e9413412) 59 seal face (part no: e14001776) 60 dowel pin (part no: e12978427) 61 flange 12 point screw 0.75x16 2.25l (part no: e13813945) 62 o ring 378 (part no: e13814055) 63 sealant, purple 300ml std31262,515 (part no: e4063063) 64 o ring (part no: e13813919) 65 o ring 269 viton 90 duro (part no: e13814054) 66 dowel pin (part no: e12631116) 67 a ring (part no: e13813093) 68 a ring (part no: e13813130) 69 dowel pin, 1/4 x 0.88 hrd (part no: e13814117) 70 back up ring (part no: e13807065) 71 dowty bonded washer (part no: e12977499) 72 back up ring (part no: e13807067) 73 a ring (part no: e13813128) 74 circlip (part no: e9413412) 75 anti seeze copper (part no: e13813826) 76 spacer (part no: e12631690) 77 sleeve (part no: e12631544) 78 disc; friction (part no: e14001397/ e12646496) 79 plate; reaction (part no: e14001398 / e12646494) 80 differential pinion bush (part no: e12637163) 81 differential pinion (part no: e6231135) 82 thrust washer (part no: e11993487) 83 differential wheel spacing washer (part no: e6231147) 84 differential bevel wheel (part no: e12631165) 85 differential bevel wheel (part no: e12631166) 86 thrust washer (part no: e6231145) 87 differential bevel wheel bush (part no: e6231158) 88 diff. cage bolt (part no: e12637185) 89 lock nut (part no: e13806851) 90 bearing cup (part no: e14500068) 91 bearing cone (part no: e14500069) 92 differential pinion brg. (part no: e12638832) 93 external circlip (part no: e6231159) 94 bearing cup (part no: e14500066) 95 bearing cone (part no: e14500067) 96 oil seal (part no: e6244376) 97 seal spacer (part no: e6237629) 98 o ring (part no: e13813116) 99 desiccant catridge kit (part no: e12980040) 100 check valve (part no: e14000841) ...

Northest Frontier Railway - West Bengal

16406471 tender for overhauling kit (m 48 schedule) prag polymers make air dryer or similar consisting of 44 itemsas per annexure. coalescer filer element kit 1.coalescer filer element 4106120=1 no.2.o ring 4107050=2nos.3. gasket 4107030=1 no.4.gasket 4106160=2 nos. desiccant canister assly kit 5.desiccant 4113070=08kg.6.o ring 4113040=2 nos.7. sleeve desiccant 4113060=2 nos.8.retaining ring a 4113031=4nos.9.retaining ring b 4113032=4 nos. purge valve assly kit 10.o ring 4109060=2 nos.11.o ring4109090=2 nos.12.cup washer 4109080=2 nos.13.seat 4109130=2 nos.14.luck nut 4109111=2 nos.15.spring4109070=2 nos. drain valve assly kit 16.o ring 4108030=1 no.17.o ring 4109060=1 no.18.cup washer4108040=1 no.19.seat 4108110=2 nos.20.spring 4108060=1 no. cut check valve assly kit 21.o ring4104050=2 nos.22.o ring 4110090=2 nos.23.o ring 4104100 =3 nos.24.cup washer 4109080=2nos.25.seat 4106080=2 nos. inlet check valve assly kit 26.o ring 4104050=2 nos.27.o ring 4106090=2nos.28.o ring4104100=3 nos. 29.cup washer 4109081=2 nos.30.seat 4106080=2 nos. compactor assly kit31.o ring 4109090=2 nos.32.o ring 4110070=2 nos.33.o ring 4110090=2 nos.34.cup washer4109080=2 nos. timer unit assly kit 35.gasket 4104250= 1 no.36.gasket 4104200=1 nos.37.seal 4104142=2nos. 38.gasket 4107030=4 nos. tower assly kit 39.o ring 4110020=4 nos.40.o ring 4104100=2 nos. afterfilter element 41.after filter element 4115010=1 no.42.o ring 4110020=1 no. 43. gasket 4107030=1 no.44.o ring 4104100=2 nos. ....

Northest Frontier Railway - West Bengal

16333409 tender for overhauling kit (m 48 schedule) prag polymers make air dryer or similar consisting of 44 itemsas per annexure. coalescer filer element kit 1.coalescer filer element 4106120=1 no.2.o ring 4107050=2nos.3. gasket 4107030=1 no.4.gasket 4106160=2 nos. desiccant canister assly kit 5.desiccant 4113070=08kg.6.o ring 4113040=2 nos.7. sleeve desiccant 4113060=2 nos.8.retaining ring a 4113031=4nos.9.retaining ring b 4113032=4 nos. purge valve assly kit 10.o ring 4109060=2 nos.11.o ring4109090=2 nos.12.cup washer 4109080=2 nos.13.seat 4109130=2 nos.14.luck nut 4109111=2 nos.15.spring4109070=2 nos. drain valve assly kit 16.o ring 4108030=1 no.17.o ring 4109060=1 no.18.cup washer4108040=1 no.19.seat 4108110=2 nos.20.spring 4108060=1 no. cut check valve assly kit 21.o ring4104050=2 nos.22.o ring 4110090=2 nos.23.o ring 4104100 =3 nos.24.cup washer 4109080=2nos.25.seat 4106080=2 nos. inlet check valve assly kit 26.o ring 4104050=2 nos.27.o ring 4106090=2nos.28.o ring4104100=3 nos. 29.cup washer 4109081=2 nos.30.seat 4106080=2 nos. compactor assly kit31.o ring 4109090=2 nos.32.o ring 4110070=2 nos.33.o ring 4110090=2 nos.34.cup washer4109080=2 nos. timer unit assly kit 35.gasket 4104250= 1 no.36.gasket 4104200=1 nos.37.seal 4104142=2nos. 38.gasket 4107030=4 nos. tower assly kit 39.o ring 4110020=4 nos.40.o ring 4104100=2 nos. afterfilter element 41.after filter element 4115010=1 no.42.o ring 4110020=1 no. 43. gasket 4107030=1 no.44.o ring 4104100=2 nos. ....