Asansol Durgapur Development Authority - West Bengal
39997714 tender for outdoor and beautification lighting at aii / 2 andrews place tagore avenue durgapur 713204 1 supply at the work site of green line road lighting luminaire ( complete set to ensure proper functioning ) with high power led and unique peanut lens to ensure uniform light distribution. make: philips ( cat. ref. brp409 led130 cw sla / m2 fg psu gr v2 / v3, spd version ) / appvd. equivalent from crompton / wipro / bajaj. analysed rate, philips led pl effective 1st feb. 2021. 2 supply at the work site of outdoorlight fittings with ip66 protection, ik08 compliant polycarbonate cover, integral type high performance led street light having single die ceramic base, high power led and pdc housing with finless design. lm 80 for led source & lm79 for luminaire is mandatory. [ make: philips ( cat no.brp 062 led 65 cw sla s1 psu, spd version or equivalent from oem ) / approved equivalent from crompton / wipro / bajaj ] . analysed rate. 3 installation of led light fittings at the outer end of erected pole arm bracket with all necessary connections including supply of requisite materials & labour for upto 10 mtr. height. rate obtained through quotations, rate vetted by kmda, lenin sarani. 4 supply and fixing of led 40w post top light fitting made of cast aluminium with decorative opal poly carbonate diffuser with ip:65 protection. make bajaj, model celesta, bgcl 40w led wh. approved equivalent from bajaj / crompton / philips. analysed rate, gh od lighting renewal job. 5 supply at the work site of 4 mtr. long 50mm dia. single gi ( tata medium ) pipe pole having fabricated & welded ms base plate of size 300mm x300mm x 4mm, gi earth bolt and suitable hole / s for passage of connecting wires. rate analysed from pwdsr 2015 16. 6 erection of single gi pipe pole of 4mtr. length as givenbelowwith / withoutsoleplate& capetc.inccfoundation ( proportionand dimension indicated below ) , having 600x600x150 mmthickcc ( 4:2:1 ) base block below sole plate / pole with hardjhamametal / stone chipsincludingcc ( 6:3:1 ) muffing0.30mts.diaand0.30mts.abovegroundlevelincluding3mmthickneatcementedfinishand gi earth bolt after making drilled holes etc. on pole &carriageofpoleupto1.6kmfromstore / place shown by departmenttowork siteincludingfillingupthe excavated earth pit with shifted soil and rammingproperly. ( 0.60 x 0.60 x 1.15 ) mtr. rate analysed from pwdsr apr. 2014, pg. h1, item 1. 7 supply, installation, connection & testing etc, . complete of robustly designed led bollard of ip 65 & ik 10 having base plate for mounting, rated lumen output, recommended operable ac voltage range at 50hz. make : philips ( model no. bcp151 led150 / ww psu 220 240v 7043 / appvd. equivalent from crompton / bajaj / wipro. analysed rate. 8 supply at the work site of ip 65 led post top lantern of system wattage of 27w having die cast aluminium housing, polycarbonate cover, integrated electronic driver and all requisite items / parts for proper functioning of supplied post top lantern. make : philips ( bgp161 led2500 ( nw ) / 2300 ( ww ) psu 220 240v 7043 in or appvd. equivalent of wipro / crompton / bajaja.rate analysed ( enclosed ) on the basis of pwd guideline and philips led pl effective feb. 2017. 9 supplying & fixing sheet steel main switch on flat iron frame on wall. 240 v d p with fuse on l & n. 30 / 32 a standard. d1, 1a + 3% district charge. 10 supply at the work site of 2c x 10 sq.mm al. conductor, xlpe insulated, armoured, overall pvc sheathed, 1.1 kv grade power cable conforming to is: 7098 ( part 1 ) 1988 with latest amendments.make: polycab / finolex / kei / havells. analysed rate, kei lp 10.05.22. analysed rate. 11 laying of one no. cable upto 35 sq.mm in underground trench 460mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 ( eight ) nos. bricks per meter, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. item no.1.a of pg. f2 of pwd ( elect. ) sr w.e.f. nov.2017 + 3 % district charge. 12 laying only cable upto 50 sq. mm through existingrcc / hume / gi pipe / open masonry trench for single, 2, 3.5 & 4 core. pwdsr nov.f1, 3a + 3% district charge. 13 laying of cables upto 2 core 25 sq. mm on wall / surface incl. s & f ms saddles with earthing attachment in 10 swg gi ( hot dip ) wire, making holes etc. as necessary mending good damages and painting. f1, 2a + 3% district charge. 14 supplying & fixing medium gauge 40 mm dia gi pipe ( isi medium ) protection with necessary fittings and jointing materials as required. f 6, 11c + 3% district charge. 15 supplying & fixing medium gauge 50 mm dia gi pipe ( isi medium ) protection with necessary fittings and jointing materials as required. f 6, 11d + 3% district charge. 16 supplying and fixing compression type gland complete withbrassgland, brass ring & rubber ring for dust & moisture proof entryofxlpe / pvc armoured cables as below: for 2core 10 sq.mm.f4, 7a + 3% district charge. 17 finishing the end of following xlpe / pvc armoured cablesbycrimping method incl. supplying and fixing solderlesssocket ( dowels make ) , tapes, anticorrosive paste & jointing materials: for 2c x 10 sq.mm. f5, 8b + 3% district charge. 18 supplying and fixing gi water proof looping cable box having hinged gi top cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, comprising of one 250v, 15a kit kat fuse unit, one nl on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing cc muffing ( 6:3:1 ) after dismantling the damaged looping cable box etc. where necy. incl. painting. 200 x 150 x100 mm. pwdsr nov.2017, pg.i2, item 16a + district charges @3% 19 earthing with 50 mm dia gi pipe 3.64 mm thick x 3.04mts. long and 1 x 4 swg gi ( hot dip ) wire ( 4 mts. long ) , 13 mm dia x 80 mm long gi bolts, double nuts, double washers incl. s & f 15 mm dia gi pipe protection ( 1mts.long ) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mts. below the ground level as below: by tata medium gi pipe. g1, 2a + 3% district charge. 20 excavation of soil for installation of earth electrode and filling and ramming. for soft soil. g 1, 1a + 3% district charge. 21 excavation of soil for installation of earth electrode and filling and ramming. for morrum soil. g 1, 1b + 3% district charge. 22 supplying & fixing earth busbar of galvanized ( hot dip ) ms flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with gi bolts, nuts, washers, spacing insulators etc. as required.g2, 4c + 3% district charge. 23 extra for treatment of soil by using salt & charcoal or coke for electrode. pwdsr nov.2017, pg.g 2, item 3b + district charges @3%. 24 supplying & fixing 415 v, tpn sfu open execution in existing ss enclosure / cubical with nuts, bolts etc. incl. s & f 3 nos. din type hrc fuse as per rating. 63a standard. pwdsr nov.2017, pg.d 4, item 4b + district charges @3%. 25 supply & installation of superior quality glow sign board of size 2’ x 2’ or equivalent size as per lettering supplied by the eic and as per direction & satisfaction of the eic complete with al requisite involvement. 26 fixing only outdoor / street light type fluorescent light fitting ormvlight fitting / led light fitting complete with all accessories to be fixed / projected from the wall of the building incl. making holes / providing clamping arrangement &necy. gi reducer as required. s&f 40 mm gi pipe ( isi medium ) quality 1.5 mts. average length having suitable bend s & f necy. length of 1.5 sqmm pvc insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. c3, 18 + 3% district charge. 27 supply at the work site of 7c x 2.5 sq.mm copper conductor, xlpe insulated, armoured, overall pvc sheathed, 1.1 kv grade control cable conforming to is: 7098 ( part 1 ) 1988 with latest amendments.make: polycab / finolex / kei / havells. analysed rate, kei lp 10.05.22. analysed rate. 28 laying of one no. cable upto 35 sq.mm in underground trench 460mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 ( eight ) nos. bricks per meter, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. item no.1.a of pg. f2 of pwd ( elect. ) sr w.e.f. nov.2017 + 3 % district charge. 29 laying of cables upto 2 core 25 sq. mm on wall / surface incl. s & f ms saddles with earthing attachment in 10 swg gi ( hot dip ) wire, making holes etc. as necessary mending good damages and painting. f1, 2a + 3% district charge....